background image

WITURA TECHNOLOGY SDN BHD

 |     

WT-1672D GSM Remote Monitor & Remote Control Switch User Manual V1.4

 

 

 

 

 

 

 

 

 

WT-1672D

 

GSM Remote Monitor and  

Remote Control Switch

 

 

 

USER MANUAL 

 

 
 
 
 
 
 
 
 

VERSION: 1.2 
UPDATED: AUG 2013 

Summary of Contents for WT-1672D

Page 1: ...WITURA TECHNOLOGY SDN BHD WT 1672D GSM Remote Monitor Remote Control Switch User Manual V1 4 1 WT 1672D GSM Remote Monitor and Remote Control Switch USER MANUAL VERSION 1 2 UPDATED AUG 2013 ...

Page 2: ... Another Call to the SIM Card will switch the device ON permanently The GSM Remote Control system supports timer function the user can set schedule to turn on off the switch For example put your pump motor on a schedule Turn off in 5 minutes turn on at 17 00 turn on 1 year later This function is important to use in the renting and leasing industry of electrical appliances heavy vehicle and rental ...

Page 3: ...sh inconsistently until it locates the network A Phone Call to the SIM Card Number will now Latch the Relay permanently ON and Switch the device being Controlled On The Status of the Relay will remain as on until the unit receives a second Call to the Unit of which will now Latch the Relay Permanently off Both Calls used to Latch the Relay either on or off are automatically disconnected once the r...

Page 4: ...hone call to the unit your mobile phone number will automatically register as the 1st Administrators You will receive the following SMS message from the unit Administrator 1 18617185300 your phone number 2 3 4 5 You already finish the set up Now you can use your mobile phone call to the SIM Card number switch the device on permanently Another call to the SIM Card will switch the device off permane...

Page 5: ...iption Programming Code SMS Texts Respond Function 1 First Step of programming you must enter the factory passwords of 1234 and go inside the programming mode You only can perform the next commands after enter into programming mode 0 1234 You get administrator privileges 2013 10 09 00 33 Wed When you enter 0 1234 you enter into the programming mode You must perform the next command in 10 minutes I...

Page 6: ...e and active the relay output You can add up to 5 telephone number into the admin list 4 Check phone number you program in the list 2 Administrator 1 15989427391 2 18617185300 3 4 5 2013019019 16 09 Thu 5 Delete the admin number in the list 3 N N Admin number 1 5 For example if you want to delete admin no 2 just enter 3 2 Administrator 1 15989427391 2 3 4 5 2013019019 17 16 Thu Delete Admin Number...

Page 7: ... Excellent System working well 8 Setting the year month day hours minutes week 12 YYYYMMDDHHMMX Time change OK 2013 10 10 16 05 Thu YYYY 4 digit for Year MM 2 digit for Month DD 2 digit for Date HH 2 digit for Hour MM 2 digit for Minutes X 1 7 Day of the Week Example set as 12 2013101016054 which means 2013 10 10 16 05 Thu If reprogram the date it will take the last as the accurate date The date h...

Page 8: ...Master relay on time Master relay off time 2013 10 10 16 33 2013 10 10 16 35 Thu Checking the schedule time for Master Relay ON OFF when the time reach the system will operate and it will delete the schedule time automatically 12 Delete the schedule time for the Master Relay ON OFF 15 N Master relay on time Master relay off time 2013 10 14 11 08 Mon N 0 Delete schedule of Relay OFF Time N 1 Delete...

Page 9: ...owledgement after you call to the unit You can switch OFF the text message Some Customer request this function because texts reply involved call cost 18 Security mode Open Mode 23 N When Setting as Security Mode 23 1 Mode switch ON 2013 10 10 17 13 Thu When Setting as Open Mode 23 0 Mode switch OFF 2013 10 10 17 13 Thu N 1 means in security mode Only allow the number in the list can text to the un...

Page 10: ...equipment it will not call the first admin number N 1 means when the equipment is switch on it will call the first admin number N 2 means when the equipment is power outage it will call the first admin number N 3 means when the equipment is line cut trigger it will call the first admin number N 4 means when over the high or low limit of temperature it will cal the first admin number N 5 means when...

Page 11: ...e for pulse counter when it reach the value set XXXXXXX is the text messages content which can up to 70 alphabet When the text message content successfully programmed it will overwrite the system default text messages 24 Check input messages programmed in the system and the 9 channels wireless alarm alert messages 27 N When Setting as 27 0 Startup user defined information The equipment has already...

Page 12: ...hich channels of Wireless Alarm Equipment that connected N 10 means Delete Input Alert Message for line cut alert N 11 means Delete Input Alert Message for pulse counter when it reach the value set If there is no text message programmed it will return a SMS with Blank Message 26 Setting Pulse Counter 29 XXXXX When Setting as 29 00030 Overplus 30 PCS 2013 10 10 17 42 Thu XXXXX 00000 to 59999 means ...

Page 13: ...they can perform this commands 32 N 32 0 The unit will latch the relay when input trigger Default Setting 32 3 When input trigger latch the relay automatically 32 4 When alarm input back to normal trigger relay OFF automatically 32 5 When Pulse counter reaching the limit trigger relay When sending 32 1 Linkage High temperature 2013 11 30 09 44 Sat N 0 means when the system have alarm alert it will...

Page 14: ...he carrier Connect the cable to terminals 220V N ensuring positive is connected to terminal 200V switch on the power supply the red power LED will light indicating power is present the blue network LED indicator will initially flash quickly once logged onto the network it will flash more slowly approximately one every 3 4 seconds It is recommended that the GSM Remote Control Switch be programmed t...

Page 15: ... qualified person Connector 1 2 3 1 2 3 4 5 Description Digital Analogue Input Relay Connection 110V 240V Industry Power Supply Digital or Pulse Counter Digital Or Analogue Temperature Input NO NC COM L N Note 1 The Temperature Input is only work with Witura Temperature Sensors 2 The Connect 4 and 5 is inside the Industry Power Supply Example Wiring Diagram For Digital And Analogue Input ...

Page 16: ...WITURA TECHNOLOGY SDN BHD WT 1672D GSM Remote Monitor Remote Control Switch User Manual V1 4 16 Example Wiring Diagram For Pulse Counter Example Connection with Washing Machine ...

Page 17: ...WITURA TECHNOLOGY SDN BHD WT 1672D GSM Remote Monitor Remote Control Switch User Manual V1 4 17 Example Connection with Coffee Machine Example Connection with Catering Equipment ...

Page 18: ...2 volts DC Operating Current Maximum 500mA typically 55mA Relay Contacts 1 x Normally Open and Normally Closed Contacts maximum switching capacity 20 amps 230v ac per relay GSM Frequency MHz GSM 850 GSM 900 GSM 1800 GSM 1900 Humidity Less Than 80 RH Operating Temperature 20c to 55c Physical Size 130 x 100 x 50mm Protection IP 65 Weather Proof Casing Approvals C E FCC ETSI ...

Page 19: ...check the PIN request status of your SIM card place the card in an unlocked mobile phone switch the phone on If you are able to make calls without entering a PIN number the PIN request is disabled If a PIN number is requested refer to the instructions supplied with the SIM card and then look through the phones options for the disable PIN request and disable it You MUST disable any voicemail that i...

Page 20: ...t messages when program the administrators number Ensure your telephone number is in the Administrator list and that sending text messages to your number is enabled 4 I am not receiving any text messages when initially programming the unit Ensure the unit is connected to the GSM network by observing the blue network LED it should be flashing once every 3 seconds see 2 above Ensure the SIM card has...

Page 21: ...d workman ship and NOT to damage due to causes beyond the control of Witura such as incorrect voltage lightning damage mechanical shock water damage fire damage or damage arising out of abuse and improper application of the equipment Note Wherever possible return only the PCB to Witura Service Centres DO NOT return the enclosure The WT 1672D is a product of Witura Technology Sdn Bhd And is manufac...

Reviews: