background image

SPECIALITY GRILLS

Gas-Fired Grill

CHURRASCO

WS-LCHUG-1200-(NG, LP)
WS-LCHUG-1500-(NG, LP)

Installation and  

Operation Manual

woodstone-corp.com

Revised June 2015 
Doc no: M0019.01

wood stone corporation

1801 w. bakerview rd.
bellingham, wa 98226 usa

tf. 800.988.8103
t. 360.650.1111
f. 360.650.1166

Summary of Contents for CHURRASCO WS-LCHUG-1200-LP

Page 1: ...CO WS LCHUG 1200 NG LP WS LCHUG 1500 NG LP Installation and Operation Manual woodstone corp com Revised June 2015 Doc no M0019 01 wood stone corporation 1801 w bakerview rd bellingham wa 98226 usa tf 800 988 8103 t 360 650 1111 f 360 650 1166 ...

Page 2: ...visit woodstone corp com wood stone corporation 1801 w bakerview rd bellingham wa 98226 usa tf 800 988 8103 t 360 650 1111 f 360 650 1166 TABLE OF CONTENTS TABLE OF CONTENTS CHURRASCO 3 CAUTIONS AND WARNINGS 4 LCHUG 1200 SPECIFICATIONS 6 LCHUG 1500 SPECIFICATIONS 7 RECEIVING ASSEMBLY 8 CLEARANCES VENTING 9 UTILITY INFORMATION 10 LIGHTING INSTRUCTIONS 12 DAILY OPERATION 13 MAINTENANCE 14 TROUBLESHO...

Page 3: ... woodstone corp com or visit woodstone corp com wood stone corporation 1801 w bakerview rd bellingham wa 98226 usa tf 800 988 8103 t 360 650 1111 f 360 650 1166 INSTALLATION AND OPERATION MANUAL FOR THE WOOD STONE CHURRASCO SPECIALITY COOKING EQUIPMENT WS LCHUG 1200 NG LP WS LCHUG 1500 NG LP GAS FIRED CHURRASCO ADDITIONAL COPIES AVAILABLE UPON REQUEST CHURRASCO Shown WS LCHUG 1200 Shown WS LCHUG 1...

Page 4: ... that this oven be installed maintained and serviced by authorized professionals DO NOT USE PRODUCTS NOT SPECIFIED FOR USE WITH THIS OVEN WARNING Improper installation adjustment alteration service or maintenance can result in property damage injury or death Read the installation operation and maintenance instructions thoroughly before installing or servicing this equipment IMPORTANT Consult your ...

Page 5: ...means of a connector for movable appliances There is a restraint on the appliance If disconnection of the restraint is necessary reconnect this restraint after the appliance has been returned to its originally installed position A MAJOR CAUSE OF FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES AIR SPACES TO COMBUSTIBLE MATERIALS IT IS OF THE UTMOST IMPORTANCE THAT THIS APPLIANCE BE INSTALLED ONLY ...

Page 6: ...AINED IN THIS DRAWING IS THE LE PROPERTY OF WOOD STONE CORPORATION REPRODUCTION OR USE IN PART OR AS A WHOLE NGOING PROGRAM OF PRODUCT IMPROVEMENT AY REQUIRE US TO CHANGE SPECIFICATIONS WITHOUT NOTICE DATE G ElectricalConnection GASINLET 16mmNPT 1 of 1 471 4 1200mm 373 4 960mm 6 150mm 193 4 500mm 551 4 1400mm 71 4 180mm TYP 71 4 190mm TYP 221 4 570mm 12 310mm 203 4 530mm 273 4 710mm 31 2 90mm 323 ...

Page 7: ...anner acceptable to the authority having jurisdiction R DATE PART LCHUG 1500 Churrasco 1500 General Arrangement 3 5 2014 bena DWN BY SHEET THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF WOOD STONE CORPORATION UT THE WRITTEN PERMISSION OF WOOD STONE IS PROHIBITED 1 of 1 55 1400mm 7 180mm TYP 491 4 1250mm 6 150mm 59 1500mm 373 4 960mm 61 4 160mm 71 4 190mm TYP 323 4 830mm 221 4 57...

Page 8: ...ide of the front of the unit and pushing down on rail The rail with 4 indentations goes in the middle position rail with 5 indentations goes on the bottom Note how weldment and the small lip at the bottom of the rail faces outward see photo below The 1200 unit comes stamdard with 9 spits Churrasco 1500 Install the Middle and Bottom Rotating Spit Rails by guiding pin into larger hole on either side...

Page 9: ...um clearance from sides of grill to non combustible construction is 36 Floor The unit is suitable for installation on combustible floors WARNING Do not pack required air spaces with insulation or other material Do not obstruct the flow of combustion and ventilation air VENTING The Wood Stone Churrasco must be vented using a Listed Type 1 exhaust hood or one constructed in accordance with the Stand...

Page 10: ...h Gas Fuel ANSI Z21 41 or CSA 6 9 ATTENTION INSTALLER EQUIPMENT RESTRAINT MUST BE PROVIDED Adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement Use the eyehooks at the rear bottom of the unit to attach the restraining device s All utility connections to the ...

Page 11: ... Stone recommends that a manual individual appliance shutoff valve be supplied located between the grill and the main gas supply and be left readily accessible MANIFOLD PRESSURE GAS RATING This appliance is equipped with a gas pressure regulator suitable for incoming pressure of up to 1 2 psi 14 W C If incoming pressure exceeds 1 2 psi 14 W C a suitable regulator by others must be installed Manifo...

Page 12: ...hen release the IGNITION button 3 Turn Pilot Knob to the ON position 1 Push and turn all Burner Control Knobs to OFF position The Low setting position OFF HIGH LOW PILOT position OFF position Red Ignition button ON position To adjust flame height depress Burner Control Knob turn to the flame height desired then release The High setting position 2 Push and turn Pilot Knob to OFF position LIGHTING I...

Page 13: ...y using an approved mild cleaning solution Stubborn residues may be removed using a non metallic scouring pad When scouring stainless steel scrub with the grain to avoid scratching the finish CLEANING THE CABINET INTERIOR When adequately cool lift and pull the Middle and Bottom Spit Rails to remove and clean Spray then wipe the interior of the cabinet walls with oven cleaner following the directio...

Page 14: ... 800 988 8103 t 360 650 1111 f 360 650 1166 MAINTENANCE WEEKLY MAINTENANCE 1 With grill cool clean the Grill Burner Radiants Wipe away any debris 2 Clean fallen debris from the lower Grease Debris Trays Grill Burner Radiants 1 Verify Gas Control knob is in OFF position 2 Unscrew the Ignitor button to access the AA battery 3 Replace battery placing negative end into spring on button sliding positiv...

Page 15: ... Clear injector Low gas pressure Increase pressure at main or grill regulator Blocked injector Clear injector Low gas pressure Increase pressure at main or grill regulator Cracked burner head Replace burner Manual shut off valve partially closed Open valve fully Pilot flame too small Raise pilot flame adjust at gas valve Low gas pressure Increase pressure at main or appliance regulator Clogged ori...

Page 16: ...om or visit woodstone corp com wood stone corporation 1801 w bakerview rd bellingham wa 98226 usa tf 800 988 8103 t 360 650 1111 f 360 650 1166 WIRE DIAGRAM CSI MOTOR SWITCH BOX WIRING DATE DIAG WD803 Rev 0 1 30 2014 Bellingham WA 1 360 650 1111 www woodstone corp com LINE GROUND NEUTRAL SWITCH BOX SWITCH LAMP GREY BLACK BLUE 4µF 220 VAC BLUE 120 VAC MOTOR SPECS Brother GL22N18X BMLC1A 1 Phase 1 5...

Page 17: ...n wood fired equipment configurations in the event that pressed log products of any type have been burned in the equipment 9 In coal fired oven configurations in the event any type of coal other than anthracite coal fuel has been used 10 Damage resulting from the use of chemical cleaning products in the oven as well as any damage from liquids or chemicals including water being poured or sprayed in...

Reviews: