background image

 

 

 

 

 

 

 

 

GUIDE

®

 EasIR-9 Thermal Camera 

 

 

User Manual 

 
 
 
 

Wuhan Guide Infrared Co., Ltd.   

No. 26 Shucheng Rd, Hongshan District, Wuhan 430070 P. R. China 

Telephone: +86-27-8767 

1991 

Facsimile: +86-27-8767 

1927 

Email: overseas@guide-infrared.com 

Internet: www.guide-infared.com 

©    Wuhan Guide Infrared Co., Ltd., 2010

 

Publication No: GUIDE® EASIR-9UM 001

 

Summary of Contents for GUIDE EasIR-9

Page 1: ...frared Co Ltd No 26 Shucheng Rd Hongshan District Wuhan 430070 P R China Telephone 86 27 8767 1991 Facsimile 86 27 8767 1927 Email overseas guide infrared com Internet www guide infared com Wuhan Guide Infrared Co Ltd 2010 Publication No GUIDE EASIR 9UM 001 ...

Page 2: ...g to electromagnetic compatibility and safety EMC directive 89 336 EEC Low voltage directive 73 23 EEC Copyright Wuhan Guide Infrared Co Ltd 2010 All rights reserved worldwide No parts of the products may be reproduced transmitted transcribed or translated into any language or computer language in any form or by any means electronic magnetic optical manual or otherwise without the prior written pe...

Page 3: ...ns 1 Maintenance 1 Calibration and Repair Philosophy 2 Technical Support 2 Feedback to Us 2 System Overview 2 System Configuration 2 Technical Specification 3 System Features 4 Parts Described 6 EASIR 9 Charging Instruction 9 Buttons Introduction 10 Function operation 14 ...

Page 4: ... welders etc Do not expose the GUIDE EASIR 9 Thermal Camera to dust and moisture When operating the unit near water ensure that the unit is adequately guarded against splashes When the GUIDE EASIR 9 Thermal Camera is not in use or is to be transported ensure that the unit and its accessories are stored in the protective carry case Do not jam the holes or loudspeaker on the camera body Do not re sw...

Page 5: ...d progress you might find features of the product have been changed since the time of printing You are appreciated to let us know about any error you find and your suggestions for further editions by either contacting the address telephone number on the cover of this User Manual or by email to the following address overseas guide infrared com System Overview GUIDE EASIR 9 is a new infrared camera ...

Page 6: ... microbolometer 384 288 pixels 25μm Spectral Range 8 14μm Thermal Sensitivity 80mk at 30 Field of View Focus 21 7 X16 4 25mm standard 40 53 X30 96 13mm 13 04 X 9 8 42mm 7 85 X 5 89 70mm optional Focus Manually Electronic Zoom X2 VISUAL Built in Digital Video CMOS Sensor 1600 1200 pixels 2 24 true colors Image Presentation External Display 3 6 TFT LCD with high resolution Video Output PAL NTSC Infr...

Page 7: ...r System Battery Type AA rechargeable battery field replaceable AA Alkaline battery also usable Charging System In camera or in battery charger Battery Operating Time Over 2 hours continuous operation External Power Operation AC adapter 110 220 VAC 50 60Hz Environmental Specification Operating Temperature 10 to 50 Storage Temperature 20 to 60 Humidity Operating and storing 10 to 95 non condensing ...

Page 8: ...operation Availability of various exchangeable lens Ultra large capacity SD memory card and built in flash memory offer easy in field storage High speed USB2 0 interface enables real time data transfer and camera control Robust on board analysis enhances operators efficiency productivity High availability of AA Alkaline battery ensures the uninterrupted high efficient work Low cost enables the own...

Page 9: ...uilt in flash memory can be downloaded to PC for further analysis and report generation with software Guide IrAnalyser Parts Described 1 LCD Display 2 Charging Indicator 3 Function Softkeys 4 Manual focus lens 5 Microphone 6 Battery Cover 7 Speaker ...

Page 10: ...User Manual 7 8 Lens lock 9 Visual Camera 11 Illuminator 12 Laser 13 IR Lens 14 Trigger Button ...

Page 11: ...User Manual 8 15 USB Interface 16 Video Interface 17 AC Adapter Charging Input Terminal 18 SD Card Slot ...

Page 12: ...f the camera is powered on when battery is low the red indicator will flicker quickly and power off automatically y When using the camera if the batteries consume to the lowest limitation the red indicator will flicker for a moment then power off automatically Note y When using the battery only when powering on and in the low battery condition the indicator will light on How to charge with batteri...

Page 13: ...and and a trigger button T Power on off the camera The input voltage is 12V keep button depressed for more than 3 seconds to power on When powering off keep the button depressed until the switch off bar runs fully To release the button at any time before the switch off bar runs fully to leave the power off state Focus and Image zoom On the non menu mode rotate the lens manually until you get a foc...

Page 14: ...oportion will be saved as the default value when start up the fusion mode next time Laser On Off On the non menu mode keep depressed for 2 seconds to turn on off the laser Ensure the Laser is On in the menu of Parameter Manual calibration On the non menu mode keep pressing T button and then press button to run shutter calibration Illuminator On Off On the non menu mode keep pressing and to enter t...

Page 15: ...image y Press to add the voice annotation the following info will be displayed on the screen xx s Record Stop Play Press to start recording voice annotation Press to stop recording voice annotation the following info will be displayed on the screen xx S Record Save Play Press to play the voice annotation y Press to enter visual light mode press again to return IR mode y Press T to return to real t...

Page 16: ...ain menu the following info will be displayed on the screen Parameter File Setup Press T in the main menu to return real time IR mode y On the main menu mode press to enter sub menu of parameter setting Emiss Tamb Distance Palette RelHum Laser Brightness OK On the sub menu mode press to confirm selecting the highlighted option and enter the next sub menu press T to exit main menu operation and ret...

Page 17: ...ra focusing Manual focus Aim at the target and adjust the lens until the image on the LCD is as clear as possible Image capturing and saving y Aim the lens at the target of interest and adjust the focus manually to get a clear image on the LCD and then pull the trigger button to capture an image The image will be frozen and bring up the image capture menu y Press Save to save the image If the SD c...

Page 18: ...isual mode full thermal mode and the confusion mode they could be switched y On real time thermal mode press the button of to go into the picture mode it would appear Visual Spot and Fusion on the button of the LCD screen y Press the button of to enter into the visual mode y Press Trigger to switch to the real time thermal status y In the picture mode with the menu of Visual Spot and Fusion displa...

Page 19: ...ngle image from the SD card y Perform the steps under viewing stored images above to bring the desired image to the display y Press the Delete y Press the Yes To delete all the images from the SD card y Press to display the main menu y Press the File y Select Del All by pressing and and OK to confirm y Press the Yes Video recording y Press to display the main menu y Press the File y Select Video b...

Page 20: ...Up to 60 seconds of voice annotation can be recorded for each image Once it reaches 60 seconds recording will stop automatically y Press Play to replay the voice annotation before saving y Press Save to save the voice annotation Listening to Voice Annotation To play the voice annotation already stored with an image on the UFlash or SD card y Perform the steps in the Reviewing and Deleting Stored I...

Page 21: ...ight emissivity value You can change emissivity between 0 01 and 1 00 in menu Para and Emissivity y Tamb To display and adjust the real time comparative scene temperature of target The default setting of this parameter is automatic adjusted by the internal temperature sensor If needed this setting can be adjusted manually according to real temperature of some special scenes like sky or snow of mea...

Page 22: ...onfirm Press the UFlash to select the storage medium as UFLASH Press the SD Card to select the storage medium as SD Card If the storage medium is set as UFLASH no hint will display on either the PC or the EasIR 9 screen Image export image analysis live video recording etc can be done in the PC Images saved in UFLASH can be transferred to PC via IrAnalyser If SD card is inserted in EASIR 9 the PC w...

Page 23: ...m a list or specific location advanced and include the folder where you save the driver program Then Click button next to go further y Installation starts When getting to the step as shown below choose Continue anyway to proceed further ...

Page 24: ...DE EASIR 9 listed under Universal Serial Bus Controller it indicates the driver has been properly installed and you can transfer data from the camera to PC now y The procedures to go to Device Manager is as follows Clicking My Computer Clicking the right mouse and choosing Property Choosing menu Hardware in the System Property dialog box Choosing option Device Manager under the menu Hardware ...

Page 25: ...User Manual 22 ...

Reviews: