background image

                                                                                          

E

                                                                   

  10/99     

        1/4

vibrationmotors

HV 6 W

Instructions of operation

and

List of spares

Important remark concerning the personal safety of operators

These instructions must be understood by each operator,
who is in charge of the assembly, putting into operation,
maintenance and repair work of vibration motors. The same
applies to supplementary instructions for modified
equipment.

Our vibration motors have been manufactured in
accordance with the latest art. In case of use as provided,
they are sure to operate.

Unauthorized changes with the motors and specific
execution for the client are excluded from the manufactures
guarantee for resulting damage. 

It is an implied feature of vibration motors that they
generate destructive forces. In case of improper use, these
destructivforces are apt to cause danger, e.g. the motor or
components thereof can drop uncontrolled after getting
loose from the fastening means. As a precaution, safety
measures must be adopted.

When performing maintenance or repair work, the vibration
motor must be disconnected from the power system.
Putting vibration motors into operation without protective
cover is forbidden, because risk of accident may result.

Instructions for mounting vibration motors

General

Vibration motors must be mounted only on equipment with
plane surfaces, which are resistant to bending. These
surfaces must not be subject to tensions.

Only screws of grade 8.8 and nuts of grade 6 must be used.
The screws must be secured from slackening, e. g. by spring
washers or the like.

Posterior tightening of screws and nuts

After the first two hours of operation the screws or nuts
must be checked for tight seating. Subsequent inspections
shall be performed once daily. In case of necessity the
screws or nuts must be retightened.

The minimum torques are for:   

M10 = 55 Nm 

 

M12 = 90 Nm

 If the screws have slackened, danger of
breakage of the feet of the vibrator is
impending.

                         screwplate         vibratorfoot

            correct                   correct                   wrong

Anweisung zum elektrischen Anschluß

Dangerous Voltage!
Non-compliance can cause death, serious
bodily injury or property damage.

General

The power connection must be established only by an
electrician. The voltage and frequency must be that, which
is indicated on the machine plate (230 V , 50/60 Hz). The
vibration motor must be connected only to power supply
which is in agreement with the VDE regulations.

!

!

!

Summary of Contents for HV 6 W

Page 1: ...bration motors into operation without protective cover is forbidden because risk of accident may result Instructions for mounting vibration motors General Vibration motors must be mounted only on equipment with plane surfaces which are resistant to bending These surfaces must not be subject to tensions Only screws of grade 8 8 and nuts of grade 6 must be used The screws must be secured from slacke...

Page 2: ...on motor into operation the power input must be examined Should this be larger than the data on the mashine plate the trouble can be remedied by reducing the centrifugal force 9 Now and again it must be checked that there are no spots which are subject to friction Admitted operating temperature Outside on the housing not higher than 80 C This limit may be surpassed by too high a power input if the...

Page 3: ...hes After every 250 hours of operation the carbon brushes should be checked for wear Remove the protective cover Push back the clamping rocker of the carbon brush holder and carefully take out the brushes out of the holder with a pair of pliers Carbon brushes of less than 8 mm length should be replaced The wires of the brushes are fitted with cable terminals and connected to the carbon brush holde...

Page 4: ...o Pieces Fig No Order No Pieces 1 46001 1 8 21301 4 17 50711 1 2 60101 1 9 21801 8 18 50801 1 3 00401 1 10 22551 2 19 75311 8 4 01401 1 11 24101 2 20 75801 1 5 01731 2 12 27001 10 21 75931 2 6 02511 2 13 29491 1 7 21101 4 16 50301 2 WÜRGES Vibrationstechnik GmbH Daimlerstraße 9 D 86356 Neusäß Augsburg telephone 0049 0 821 463081 telefax 0049 0 821 463084 e Mail info wuerges de Internet http www wu...