Page 1: ...User Manual ProConnected Smoke Alarm Model XS03 iWX...
Page 2: ...troduction The X Sense XS03 iWX smoke alarm monitors for smoke concentration and can beinterconnected with other devices of the same type XS03 iWX It needs to be paired with the X Sense SBS10 base sta...
Page 3: ...er ignore an alarm Failure to respond can result in serious injury or even death 2 The silence feature is only for your convenience and will not correct a problem Always check your home for any potent...
Page 4: ...tion first before adding this smoke alarm You enable Bluetooth services on your smartphone The base station has a stable connection by placing it within the router s range 1 Tap the button in the app...
Page 5: ...D indicator has been combined with the Test Silence button on the device When you press the Test Silence button note that your finger could cover the button so that you may not be able to see the indi...
Page 6: ...h Notifications Enable push notifications from the app to receive alerts of any changes to the system It is recommended that you limit your notifications to specific ones that you would like to receiv...
Page 7: ...wn layout to create a home fire safety system Note that the base station needs to be placed in the center of the house so all devices stay well within its range Study Bedroom Garage Living Room Kitche...
Page 8: ...so install the alarm in the middle of the ceiling where possible 4 If an alarm cannot be installed in the middle of a ceiling install it at least 20 inches 50 cm away from all corners of a room 5 If...
Page 9: ...smoke when smoke rises If you can t do this place the alarm at least 20 inches 50 cm from the corners If you install the alarm on a wall place it at least 4 inches 10 cm from the highest point Keep t...
Page 10: ...or wall using the mounting bracket as a guide 2 Drill holes at the two marked positions with a drill bit Insert the anchor plugs then attach the mounting bracket using the provided screws 3 Attach the...
Page 11: ...red Four beeps every 5 8 seconds if a CO alarm is triggered App No push notifications Note If the smoke concentration drops below the alarm limit the device will cease to alarm and return to standby m...
Page 12: ...e still alarming is the initiating device Note that the silence function will only silence the alarm for a short period It will not correct any problems Device Status Checklist Device Status LED Indic...
Page 13: ...ype Photoelectric Safety Standards UL 217 Coverage Area 1640 feet 500 m in open air Operating Temperature 40 100 F 4 4 37 8 Operating Relative Humidity 85 non condensing Alarm Volume 85 dB at 10 ft 3...
Page 14: ...n Do not disassemble the device to clean the interior Doing so will void your warranty Weekly Test Test the alarm when you turn on the device for the first time once a week and every time you replace...
Page 15: ...ances dusty areas showers or any areas where the temperature drops below 40 F 4 4 C or rises above 100 F 37 8 C See the Location and Installation section Clean the alarm every three months to avoid un...
Page 16: ...eiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or...