background image

TX90 6kVA & 10kVA Online UPS

6kVA, 10kVA Models

User & Installation Manual

www.xpcc.com

 

| © 2015 Xtreme Power Conversion Corporation. All rights reserved. (Rev 5/26/15)

Summary of Contents for 6kVA

Page 1: ...TX90 6kVA 10kVA Online UPS 6kVA 10kVA Models User Installation Manual www xpcc com 2015 Xtreme Power Conversion Corporation All rights reserved Rev 5 26 15...

Page 2: ...ion And Operation 12 Unpacking 12 Selecting Installation Position 12 TerminalBlockExplanation 12 InputConfiguration 13 OutputConfiguration 14 Start Up in Normal Mode 15 Check Measured Values and Figur...

Page 3: ...rvice 31 Xtreme Power Conversion Limited Warranty 32 Xtreme Power Conversion Load Protection Policy 33 Appendix A T90 EBP920 EBP940 EBP960 User Guide 36 Introduction To The Rear Panel 37 Installation...

Page 4: ...ny UPS Install the UPS away from objects that give off excessive heat and areas that are excessively wet If liquids are spilled onto the UPS or foreign objects dropped into the unit the warranty will...

Page 5: ...E INSTRUCTIONS CAUTION Do not dispose of batteries in a fire The batteries may explode CAUTION Do not open or mutilate batteries Released electrolyte is harmful to the skin and eyes It may be toxic CA...

Page 6: ...unit become overheated the internal thermal switch will detect the heat and switch to bypass mode and vice versa The fully digitalized control circuit built into the UPS allows upgrading the functiona...

Page 7: ...ility is abnormal the batteries will be boosted to provide the DC voltage to the Inverter 5 Internal Battery When AC abnormal it provide the backup power from the batteries 6 Charger the battery charg...

Page 8: ...specified mode 6 A Blackout Transfer occurred in UPS Output 7 Bypass Input Abnormal UPS fails to transfer to bypass Bypass Abnormal at ECO mode 8 Utility Input Abnormal 9 OFF UPS Shut off 10 LINE OFF...

Page 9: ...Wrong Procedure to Enter Maintenance Mode 33 Er16 Output Parameters Set Error in Parallel System 34 Er17 ID Numbers are in conflict in Parallel System or ID number error in single unit 35 Er21 Parall...

Page 10: ...ing green LED indicates that the utility input voltage is outside the acceptable window 4 Green LED indicates that Bypass Input is normal 5 UPS ON Alarm Silence 6 Go to previous page or change the set...

Page 11: ...optional interface cards for Relay Dry Contact and SNMP These cards may be used simultaneously The software bundled with the UPS is compatible with many operating systems such as Windows 98 2000 ME N...

Page 12: ...Position Install the UPS in a proper environment to minimize the possibility of damage to the UPS and to extend the life of the UPS Please follow these requirements 1 Keep at least 12 inches clearance...

Page 13: ...configured at 208V but the actual input is 240V then the output voltages will boost up 15 Input Configuration 208V input applications 208V input with a 120 240V output is the default for these systems...

Page 14: ...ity output Please note the jumpers between G2 N22 N22 N21 and L22 L21 for this option See below For any other output configurations needed please contact Xtreme Power Tech Support Please refer to the...

Page 15: ...Utility and Bypass inputs are normal UPS will display first figure A1 and then figure B A1 B The UPS is now in Bypass Mode It will proceed to self test automatically If no abnormal message appears the...

Page 16: ...e protected Start up in Battery Mode Cold Start Make sure the UPS has at least one string 20 pcs of batteries Push the UPS On switch once for approximately 5 seconds to wake the UPS The buzzer will so...

Page 17: ...es detected by the UPS use the scroll up and scroll down keys When you scroll down the LCD will display figure C Voltage from Utility Input figure I1 Voltage from Bypass Input figure J Frequency from...

Page 18: ...ower Conversion Corporation TX90 6kVA 10kVA User s Manual Page 18 Uninterruptible Power Supply K Frequency of Bypass Input L UPS output voltage M UPS output frequency N UPS output load level O Battery...

Page 19: ...ill display in sequence figure Q1 buzzer figure R Self test figure S Bypass Voltage Windows figure T Output Frequency Synchronization Window figure U Inverter Output Voltage figure V UPS Operation Mod...

Page 20: ...ectable to 1Hz U Inverter output voltage set to 208V Selectable to 200 208 220 230 240V This is the voltage sent to the output transformer primary The UPS output voltages depend on what output con fig...

Page 21: ...ndicates the bypass frequency window of the Inverter Output The acceptable setting values are 3 Hz and 1 Hz Figure U indicates the acceptable Inverter Output Voltage Possible values are 200 208 220 23...

Page 22: ...blem For further help consult your local distributor 3 Press the Off key for five seconds A buzzer will sound twice 4 Turn Off the Utility Input breaker 5 Even if the UPS lock problem is solved now co...

Page 23: ...enance now 5 When you are done with UPS maintenance put the UPS back into normal working mode as explained previously Then return the CAM switch to INV mode replace the cover The UPS will switch back...

Page 24: ...uncritical load at the UPS output end If there is any damage to the insulation of the AC power cord please replace it with a new one EPO Remove the short circuit at the EPO terminal Er11 Er33 Remove a...

Page 25: ...Connect the male connector of the RS 232 cable to the UPS communication port 2 Connect the female connector of the RS 232 cable to a dedicated RS 232 port of the attached computer Software Installati...

Page 26: ...function will be activated after 6 25 VDC is applied between pin 9 and pin 10 for 5 sec onds The capacity of each relay contact is 40 VDC 25mA Installation Position slot 1 CHA CN7 or slot 2 CHB CN8 Fl...

Page 27: ...Xtreme Power Conversion Corporation TX90 6kVA 10kVA User s Manual Page 27 Uninterruptible Power Supply Interface Card Installation 1 3 2...

Page 28: ...by qualified personnel only 1 Unscrew the bottom of the front panel as indicated in Step 1 below 2 Remove the front panel as indicated in Step 2 TX90 6K shown above 3 Remove the screw of the battery...

Page 29: ...Conversion Corporation TX90 6kVA 10kVA User s Manual Page 29 Uninterruptible Power Supply 6 Rotate the battery pack handle 90 degrees as shown in Step 6 7 Remove the battery packs from the UPS as sho...

Page 30: ...x 25 4 x 34 7 in Weight 265 lbs 340 lbs OPTIONAL Battery quantity and size EBP920 20 12V 9AH EBP940 40 12V 9AH EBP960 60 12V 9AH BATTERY PACKS Dimensions W x D x H 11 4 x 25 4 x 29 5 in Weight EBP920...

Page 31: ...will ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Mate rial Autho...

Page 32: ...the equipment is repaired or modified by anyone other than XPC Corporation or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjecte...

Page 33: ...the XPC Limited Warranty against certain losses caused by a Power Disturbance for properly connected electronic equipment referred to as the Connected Equipment subject to certain terms and conditions...

Page 34: ...e Load Protection Policy The following damage is not covered by this Policy 1 Restoration of lost data and reinstallation of software 2 Damage from a cause other than AC power line transients except f...

Page 35: ...issue payment to the Purchaser for either the cost of repair of the Connected Equipment or the Fair Market Value of the damaged Connected Equipment up to the dollar limits stated above XPC reserves t...

Page 36: ...r poured directly onto the battery bank Similarly we do not warrant any damage to the battery bank if foreign objects are deliber ately or accidentally inserted into the battery bank enclosure The bat...

Page 37: ...Corporation TX90 6kVA 10kVA User s Manual Page 37 Uninterruptible Power Supply Introduction To The Rear Panel Rear Panel Descriptions T90 EBP920 EBP940 EBP960 Product Label DC Breaker UPS Connector Ba...

Page 38: ...ect cable o The casters cover kits Selecting Installation Position It is necessary to select a proper environment to install the unit in order to minimize the possibility of damage to the battery bank...

Page 39: ...Xtreme Power Conversion Corporation TX90 6kVA 10kVA User s Manual Page 39 Uninterruptible Power Supply Installation of Casters Cover Installation Instructions...

Page 40: ...ersion Corporation TX90 6kVA 10kVA User s Manual Page 40 Uninterruptible Power Supply Specifications T90 EBP920 T90 EBP940 T90 EBP960 Dimensions W x D x H Unit 11 4 x 25 4 x 29 5 in Weight Unit 254 lb...

Reviews: