ORAYA

 D

ATACUBE

-N3 

User Manual 

 

Version: 1.1 / March 2020

 

Summary of Contents for XORAYA DATACUBE-N3

Page 1: ...XORAYA DATACUBE N3 User Manual Version 1 1 March 2020 ...

Page 2: ... Reproduction of this user manual even in part is only permitted with the approval of X2E GmbH Any infringement will result in liability for damages and may result in criminal prosecution All product names and brands used in this user manual are the property of their respective owners ...

Page 3: ...ts 4 Safety 5 Safety labels on the device 5 General safety instructions 5 Connections and controls 6 Installation 9 Mounting 9 Connecting 9 XORAYASuite 11 Network settings 12 Download 14 Hdd Download 14 Automatic download service 17 Update firmware 19 Cleaning 20 Repair 20 Transport 20 Disposal 20 ...

Page 4: ...s user manual Additionally the use in hazardous areas is not allowed The data lines may be extended up to a maximum of 30 m if they are sufficiently shielded In case of optical signal lines the maximum length depends on the used transceivers and ca bles Delivery contents XORAYA DATACUBE N3 with mounting brackets software user manual power cord optionally telescopic rails for rack mounting optional...

Page 5: ...or the power cord can result in electric shock Check all components regularly for damages Only connect the DATACUBE N3 if all components are undamaged CAUTION Device damage due to vibrations dirt or liquids Excessive vibrations dirt or liquids may result in malfunction or destruction of the DATACUBE N3 Avoid exposing the DATACUBE N3 to excessive vibrations dirt or liq uids Keep the DATACUBE N3 cle...

Page 6: ...User Manual XORAYA DATACUBE N3 6 Connections and controls Front view Back view ...

Page 7: ...n for at least one second before disconnecting the XORAYA RSU The integrated LED displays the connection state LED Meaning red connection enabled locked green connection disabled through button unlocked Power input E and power switch F Use the provided power cord to connect the DATACUBE N3 to a suitable power source Technical data of the built in power supply Power 650 W Input 100 240 V AC 50 60 H...

Page 8: ... port LEDs J LED Colour Meaning Activity right flashing green data is transferred Link left green 10 Gbit s orange 1 Gbit s Supported QSFP transceiver modules and cables for the network interface card K Chelsio SM40G SR SM40G LR Chelsio QTAPCABLE1M QTAPCABLE3M QTAPCABLE5M FS Chelsio SM40G SR Compatible 40GBASE SR4 QSFP Transceiver Module MMF 850nm 150m MTP MPO DOM FS Chelsio SM40G IR Compatible 40...

Page 9: ...DATACUBE N3 two people should perform the installation Use either the optionally available telescopic rails or a custom and safe fixing method The mounting brackets at the sides of the front panel serve as an additional fixation They are not suited as the sole means of mounting Connecting XORAYA RSUs CAUTION Burning hazard due to hot surfaces Continuous operation can strongly heat up housing and h...

Page 10: ...tion to the correct orientation of the QSFP transceiver module and carefully push it in until it locks in place Connect PC or switch via a standard network cable to one of the ports J K Ensure proper connector seating Power supply CAUTION Device damage due to wrong power supply A wrong power supply can result in damage or destruction of the DATACUBE N3 Use the provided power cord Only connect the ...

Page 11: ...stems Microsoft Windows 7 32 Bit or 64 Bit Microsoft Windows 8 32 Bit or 64 Bit Microsoft Windows 10 32 Bit or 64 Bit Hardware requirements Processor speed at least 1 GHz RAM at least 2 GB Hard disk space approx 120 MB available Software requirements Microsoft NET Framework Version 4 5 or higher Install XORAYASuite Start the setup wizard and follow the instructions ...

Page 12: ... Windows notification area Select Extra tools HWFinder Start web interface In the drop down list Device class select DATACUBE Double click the row of the desired DATACUBE N3 or Highlight the row and click Web GUI The web interface opens in your browser Start web interface directly in browser Alternatively enter the IP address or the name of the DATACUBE N3 directly into the browser address bar to ...

Page 13: ... the left side select the category Network configuration Click the desired port in the graphic or Click one of the tabs Port A to Port D Activate the Editmode Change the Mode and enter IP address Subnet mask and Standard gateway if needed Click Save ...

Page 14: ...ource and PC and put one or more XORAYA RSUs in see chapter Connecting Press the power button C The DATACUBE N3 is ready when the power LED is green Click Display available loggers 1 to start scanning for dataloggers and DATACUBEs Select the desired DATACUBE N3 Click Establish connection to logger 2 The DATACUBE N3 is connected with the Hdd Download tool An additional window opens to choose one fr...

Page 15: ...cify start date a and start time b of the desired time range Specify the end date c Use the arrows d optionally to apply the start date or to jump one day forward or backward Specify the end time e Click Apply f Limit the time range further by clicking and dragging inside the graphical representa tion g History The time ranges defined since starting the tool can be selected again via the History b...

Page 16: ... to switch between dif ferent statistics The symbol displays the current value during download and the average as the process completes Click Show download statistics 8 to display statistical data graphically Cancel download Click Stop download from logger 4 Analyse log data Click 7 to open the last used folder in Windows Explorer Disconnect DATACUBE N3 Click Release connection to logger 2 DATACUB...

Page 17: ...ice This XORAYASuite extra tool is a server which automatically downloads log data from se lected DATACUBEs and dataloggers Start the XORAYASuite Click in the Windows notification area Select Extra tools DataCube Download settings Click 3 to open the settings ...

Page 18: ...ts In the category Measurement select restrict the log data to download for example by setting a start date Additionally you can configure that after downloading log data is automatically deleted from the XORAYA RSU and the RSU is unlocked After configuring all settings click Accept Start server Click Start Server 1 After 5 seconds the server scans for the selected devices connects and automatical...

Page 19: ...the category Firmware Update Click Browse 1 and select a suitable XSWU file Click Update 2 Update firmware via USB flash drive If the firmware update is available as an ISO file write it to a USB flash drive and insert the drive into one of the USB 3 0 ports H I The DATACUBE N3 automatically performs the firmware update The web interface is not needed ...

Page 20: ...2E personnel only In case of malfunctions or damages please contact X2E via e mail to get information about returning the DATACUBE N3 xoraya return x2e de Transport Always transport the DATACUBE N3 without inserted XORAYA RSUs Use the front panel handles of the DATACUBE N3 Disposal Within the European Union the disposal of electrical devices is determined by national rules that are based on the di...

Page 21: ......

Page 22: ...X2E GmbH Jahnstrasse 2b 76870 Kandel GERMANY Phone 49 7275 9143 100 Fax 49 7275 9143 109 E Mail info x2e de Internet http www x2e de ...