background image

CM12500P Battery Charger

User Manual

EN

Version AU V1.0 

Summary of Contents for CM12500P

Page 1: ...CM12500P Battery Charger User Manual EN Version AU V1 0 ...

Page 2: ......

Page 3: ...ry or any legal responsibility incurred directly or indirectly from the use of this product XAG reserves the rights for final interpretation and revision of the Terms and conditions herein to the extent permitted by law XAG also has the right to update modify or terminate these terms and conditions via its official website without prior notice This document and all other collateral documents are s...

Page 4: ...ercurrent protection Overheat protection Under voltage protection Fault Isolation and Status Indicator Battery Charger will terminate the charging process and switch off the battery automatically when the battery is fully charged List of Item SuperCharger X1 16A Power Cable X1 Overview CM12500P Battery Charger AC Power Port Power Input Indicator Cooling Fan Handle Charging Terminal Charging Output...

Page 5: ...en Not Grounded Risk Exist Solid Red Error Protection Triggered Output OFF Flashing Red Overheated Protection Triggered Output OFF Status Indicator Charging Output indicator Status Description Solid Green Idle Idle Flashing Green Offline No Battery or Connection error Solid Red Charging Charging ...

Page 6: ...charging device with alcohol or other combustible liquids X DO NOT disconnect the AC cable or the Charging cable while the Charger is in use Remove batteries after charging is completed X DO NOT use this product under direct sunlight in rain or in a humid environment IMPORTANT The battery management system will automatically suspend the charging if the temperature is over 55 C and resume after the...

Page 7: ...7 XAG AUSTRALIA Charging with CM12500P Battery Charger Charging with GC4000 Auto SuperCharger Station Charging with GC4000 Auto SuperCharger Station with Water Cool Charging Tank ...

Page 8: ...m x 337mm Weight Approx 9 0 kg Operating Temperature 10 C to 45 C Storage Temperature 20 C to 55 C Cooling Mode Outer Air Cooling Operating Altitude 3000m Input AC 90 165V 50 60Hz 23A Max AC 180 260V 50 60Hz 23A Max Output DC 50 60V 25A Max 1250W AC 90 165V 50 60Hz DC 50 60V 50A Max 2550W AC 180 260V 50 60Hz Warranty Details 12 Months ...

Page 9: ...lustrations photos methods processes etc belongs to XAG Australia and is protected by copyright law No individual or organization may imitate extract translate distribute or reproduce or quote all the contents of this manual without any written authorization Copyright 2022 XAG Australia All Rights Reserved ...

Reviews: