INSTALLATION INSTRUCTIONS
MRCKPSP
Multi-Room Controller, Keypad Splitter
DESCRIPTION
The MRCKPSP provides the installer with the ability to wire two keypads to one zone without daisy-
chaining the keypads in the zone. This makes pre-wiring instructions an easier task by allowing the
installer to “home-run” all keypad cables. Plus, the MRCKPSP comes with an additional IR receiver
input/output connection.
The MRCKPSP can be used with the following products.
►
MRC44CTL
►
MRAUDIO4X4CTL
►
BXAUDIO4X4CTL
►
MRC88CTL
►
MRAUDIO8X8CTL
BASIC INSTALLATION - MRC44, MRAUDIO4X4, BXAUDIO4X4
The MRCKPSP is designed to easily connect two keypads in a zone. Figure 1 shows a
recommended application. The power jumper must be set to “INT”. This enables the multi-room
controller to power the primary and secondary keypads.
MRC44 Controller (rear)
MRC44 Keypad
(primary)
MRC44 Keypad
(secondary)
ON
OFF
INT
MRCKPSP
MRC KEYPAD SPLITTER
CONTROLLER
KEYPAD
2
KEYPAD
1
POWER EXT.
(OPTIONAL)
+12VDC
1 2 3
INT
.
EXT
.
+12V
GND
ST
ATUS
IR IN/OUT
POWER
MRCKPSP
MRC KEYPAD SPLITTER
CONTROLLER
KEYPAD
2
KEYPAD
1
POWER EXT.
(OPTIONAL)
+12VDC
1 2 3
INT
.
EXT
.
+12V
GND
ST
ATUS
IR IN/OUT
POWER
Figure 1
The primary keypad must have both the “secondary” and “zone termination” jumpers removed. The
secondary keypad must have both the “secondary” and “zone termination” jumpers installed. The
distance between the MRCKPSP to the MRC44 Keypads is 250 feet maximum. The distance
between the MRCKPSP and the multi-room controller is less than 15 feet.
-
1
-