background image

RDS - 1

Reso-not

TM 

Damping System

XCITE

1001P FIELD TEST POWER SUPPLY

 
 

 

 



 

 

 

 

XCITE

Owner’s Manual

Xcite Systems Corporation 

 675 Cincinnati Batavia Pike 

 Cincinnati, Ohio  45245

Tel: (239) 980-9093 

 Fax: (239) 985-0074 

 Email: info@xcitesystems.com 

 Web: www.xcitesystems.com

Summary of Contents for 1001P

Page 1: ...System XCITE 1001P FIELD TEST POWER SUPPLY XCITE Owner s Manual Xcite Systems Corporation 675 Cincinnati Batavia Pike Cincinnati Ohio 45245 Tel 239 980 9093 Fax 239 985 0074 Email info xcitesystems com Web www xcitesystems com ...

Page 2: ...on of Xcite Systems Corporation and is tendered subject to the conditions that the information a be retained in confidence b not be reproduced or copied in whole or in part and c not be used or incorporated into any product except under an express written agreement with Xcite Systems Corporation P 2 ...

Page 3: ...1001P Field Test Power Supply ...

Page 4: ...ects through a 2 micron filter A relief valve maintains a constant 3000 psi output pressure by bleeding flow to the reservoir The user must be aware that when more than 1 2 GPM is demanded by the exciter head low frequency stoke or weak structure stiffness at higher frequencies the pump pressure will drop For maximum force capability from the system the stroke must be limited to ranges which allow...

Page 5: ...ply from either 115 VAC or 230 VAC 60 Hz Drawing B 30222 and B 30224 depicts the voltage selector switch in the 230 Volt position In this position voltage is applied to the primary coil of transformer T 1 and is stepped down to 115 VAC for operation of all control relays and the Xcite Master Controller When the voltage selector switch 107PB is switched to the 115V position 115 VAC power is applied...

Page 6: ...Gauge This gauge indicates the supply pressure at the pump outlet With no flow the gage should normaly read 3000 to 3100 psi 3 2 Power Indicator Lamp This lamp is illuminated at all times when the electrical power cord is connected to the power outlet 3 3 Emergency Stop Switch and Remote Emergency Stop Connector This is a push to stop switch that de energizes the pump motor starter when depressed ...

Page 7: ...huts down the unit if the oil level is too low or if the oil temperature exceeds 140 F Indicator lamps are illuminated on the front panel of control box 1 if the oil level is too low or the Hydraulic Power Supply is over its temperature limit 3 10 Filter Switch The filter switch is mounted on the filter assembly located at the output of the pump If the differential pressure across the filter eleme...

Page 8: ...8 Press the PUMP START button on the Master Controller to start the pump To stop the unit press the PUMP STOP button on the Master Controller or the EMERGENCY STOP button on the pump s front panel 4 9 Check the pressure gauge and verify the pump is operating at 3000 to 3200 psi Failure to comply with the above can cause severe damage to the servovalve exciter head and pump All warranties are inval...

Page 9: ...p operation If the supply is to be transported such that the cabinet could be tipped over the oil should be drained from the reservoir See draining and filling procedure in Section 2 1 5 3 Change Oil Filter Unscrew the bottom of the container and change the cartridge See Drawing B 30221 Item 13 for filter model number 6 Troubleshooting This section lists the most common problems encountered as wel...

Page 10: ...l DTE 24 or DTE 25 DO NOT MIX OIL TYPES Operating Pressure 3000 psi 5 Pressure Control Spring operated relief valve Pump 1 2 GPM constant displacement at 1725 rpm Motor Full Load 3 hp single phase 115VAC 27 Amps 230VAC 13 5 Amps 1725 rpm 184 TC frame size Radiated Noise Front 72 db at 3 ft from cabinet Side 68 db Rear 74 db 8 Drawings Assembly Hydraulic Power Supply B 30220 Hydraulic System Schema...

Reviews: