background image

INDEX

 

USER MANUAL - OPTIMA RT9W 1K/2K/3K 

 

 

www.xmart-ups.com 

VER.171130-WP+-ENG

 

VER. 1711.30 

 

ENGLISH 

 

 

 

 

USER MANUAL 

OPTIMA RT9W 1K/2K/3K

 

 

 

UPS ONLINE DOUBLE CONVERSION 

RACK / TOWER INSTALLATION 

 

230V SCHUKO  

120/220V IEC 

120V NEMA 

220V NEMA 

 

 

 

 

 

 

Technical information on this manual is property of XMART 

 This manual Information cannot be copied or distributed totally 

or partially without written approval of XMART. 

 

XMART can introduce modifications in their products or manuals without further notice. 

 

XMART is not responsible of mistakes or missing information in this manual. 

 

XMART is not responsible for wrong use a third part can do of this information. 

 

Trademarks and logos in this manual are property of their owners. 

 

Summary of Contents for OPTIMA RT9W 1K

Page 1: ...n this manual is property of XMART This manual Information cannot be copied or distributed totally or partially without written approval of XMART XMART can introduce modifications in their products or...

Page 2: ...ONS 2 PRODUCT DESCRIPTION 3 SAFETY QUALITY AND PERFORMANCE STANDARDS 4 INSTALLATION 5 OPERATION MODES 6 OPERATION INTERFACE KEYBOARD LCD 7 UPS CONFIGURATION 8 ERROR ALARMS CODES 9 TROUBLESHOOTING 10 S...

Page 3: ...its own power outlets this could damage the unit permanently WARNING Do not connect AC motor based equipment without a careful sizing of the UPS based on inrush current instead of average current Inr...

Page 4: ...of this product as a part of a more complex system not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment It also could affect its per...

Page 5: ...y by these handles 1 Install black handles to the UPS 2 Make sure rack cabinet counts with required mounting guides 3 Place UPS on the guides and fix it to the cabinet using black handles VERTICAL MOU...

Page 6: ...must connect line neutral and ground to input terminal block using cables with required gauge to drive maximum rated current For 3KVA UPS in 120V wires must be minimum 12AWG for lengths shorter than...

Page 7: ...off 2 Bypass mode is adopted as soon as a problem is detected in its internal circuitries 3 Bypass mode is also activated in case an external overload is detected in UPS output It happens when equipme...

Page 8: ...y UPS inverter C AC input symbol must be turned off representing there is no valid AC input detected by UPS D Clock symbol lights and backup time is displayed on the screen BYPASS MODE A Input and out...

Page 9: ...R UPS TURN OFF Press for 2 seconds to turn UPS off ENTER When UPS is in configuration mode this key operates as ENTER SELECT CHECK VALUES UPS can show in alternative cycle all available values by push...

Page 10: ...INFORMATION It displays AC output voltage Output frequency in Hz ALARMS ERRORS This section of the LCD displays active alarms and errors providing codes and descriptive symbols This section also shows...

Page 11: ...5 BYAPSS internal static line active 6 ECO mode active 7 Audible alarm beep muted OUTPUT POWER METER This area displays graphically by a 4 segments bar the power supplied by the UPS 25 Supplied Power...

Page 12: ...configuration mode LCD displays ID of the menu and values of 2 adjustable parameters 1 MENU ID 2 Function name 3 Configurable value KEYBOARD IN CONFIGURATION MODE ON MUTE Used as key to navigate or ch...

Page 13: ...F 50 50Hz CF 60 60Hz 04 ECO ENABLE DISABLE ENA ENABLE DIS DISABLE Factory set DIS Check more details at operation modes section 05 ECO INPUT VOLTAGE RANGE Vac Function 02 High Limit Function 03 Low Li...

Page 14: ...n Funci n de Convertidor de Frecuencia CH Charger Cargador de Bater as ESC Escape Salir ON ON Encendido ENA Enable Habilitado DIS Disable Des habilitado HLS High Loss L mite superior del rango LLS Low...

Page 15: ...ms are generated when UPS detects an abnormal situation but UPS can continue working in ONLINE mode However it is important operator revise condition that generated alarms and take actions to solve it...

Page 16: ...ON ERROR CODE ERROR SYMBOL DC BUS start failure 01 DC BUS High 02 DC BUS Low 03 DC BUS Unbalanced 04 INVERTER start failure 11 INVERTER High voltage 12 INVERTER Low voltage 13 SHORT CIRCUIT detected a...

Page 17: ...f not solved call technical service ERROR CODES PROBABLE CAUSE SOLUCION 01 02 03 04 Turn off and power off UPS Disconnect all equipment connected to UPS Restart UPS with no loads connected to its outp...

Page 18: ...eratures will short dramatically battery life IMPORTANT RECHARGING PLAN FOR LONG STORAGE If UPS will be stored for long time it is mandatory to recharge UPS periodically If UPS is not recharged accord...

Page 19: ...3 BATTERIES 36VDC MODELS 1 5KVA 1 Remove old batteries 2 Connect 2 batteries in series 3 Install new batteries in the binder 4 Close binder BATTERY REPLACEMENT 4 BATTERIES 48VDC MODELS 2KVA 1 Remove o...

Page 20: ...ion service partners reserve the right to charge handling fee if returned product is free of failure or it is out of warranty because any of the reasons described in this warranty 6 If product is out...

Page 21: ...rotected sockets in Out C SELECT 6 Not used D OFF ENTER 7 USB RS232 ports 1 Standard UPS outlets 8 Intelligent SNMP port 2 IEC C20 outlet 16A IEC model only 9 External Battery connector optional in so...

Page 22: ...INDEX USER MANUAL OPTIMA RT9W 1K 2K 3K www xmart ups com VER 171130 WP ENG 22...

Page 23: ...INDEX USER MANUAL OPTIMA RT9W 1K 2K 3K www xmart ups com VER 171130 WP ENG 23...

Page 24: ...12V 9AH 6 x 12V 9AH 27 4 VDC 1 54 7 VDC 1 82 1 VDC 1 276 491 737 100 105 warning 105 110 10min to bypass 110 130 1min to bypass 100 105 warning 105 110 10min to bypass 110 130 1min to bypass 110 120 3...

Page 25: ...ows to set output frequency at constant value 50Hz or 60Hz El modo de Conversi n de Frecuencia permite fijar la salida a 50 o 60Hz Runtime for loads 80 is limited to 4min For loads between 70 and 80 r...

Page 26: ...INDEX USER MANUAL OPTIMA RT9W 1K 2K 3K www xmart ups com VER 171130 WP ENG 26 NOTAS...

Page 27: ......

Page 28: ...NW 26th St Doral FL 33172 USA sales xmart ups com EUROPE Ave Can Bordoll 60 Nave 4 Sabadell 08202 Spain sales xmart ups com Latin America Zona Ind San Vicente II C F A11 Maracay Venezuela sales xmart...