background image

 

Xorcom USA

 

2012 W. Lone Cactus Drive 
Phoenix, AZ 85027 USA 
Tel: 1-866-XORCOM1 

info.usa@xorcom.com

 

 

www.xorcom.com

 

Xorcom Ltd.

 

Teradyon, POB 60 
D.N. Misgav 20179, Israel 
Tel: +972-4-9951999  

info@xorcom.com

 

 

Astribank PRI - Quick Start Guide 

 

Port PINs Layout 

The Astribank PRI unit has two 
RJ-45 sockets for each PRI 
port.  Both sockets are 
permanently active and can be 
used with any configuration 
parameters.  
 
The lower socket provides typical E1/T1 TE (CPE) side wiring: 

 

Rx pins: 1, 2 

 

Tx pins: 4, 5 
 

The upper socket provides typical E1/T1 NT (Network) side-wiring: 

 

Rx - pins 4, 5 

 

Tx - pins 1, 2 

Port LED Indicators 

The green LED of the lower socket indicates the line status when the port is 
configured as TE. The yellow LED of the upper socket shows the line status when the 
port is configured as NT. 

Table 1: Port Status LEDs 

Continuous yellow 

Indicates that the port is configured as NT 

Two fast green blinks 

Indicates that E1/T1 layer 1 is active 

Single yellow blink 

Indicates that ISDN PRI layer 2 is active 

1) 

 

1)

 More precisely, this indicates that there is some Layer 2 messages exchange. 

Sometimes it doesn't mean that the Layer 2 connection has been established. 

Summary of Contents for Astribank PRI

Page 1: ...x pins 4 5 The upper socket provides typical E1 T1 NT Network side wiring Rx pins 4 5 Tx pins 1 2 Port LED Indicators The green LED of the lower socket indicates the line status when the port is configured as TE The yellow LED of the upper socket shows the line status when the port is configured as NT Table 1 Port Status LEDs Continuous yellow Indicates that the port is configured as NT Two fast g...

Page 2: ...ocumentation 1 The Zaptel Init Configuration File is either etc default zaptel on Debian Ubuntu etc etc sysconfig zaptel on RedHat CentOS etc The information defined in this file is used by Zaptel and some Zaptel utilities For example the genzaptelconf utility uses information from XPP_PRI_SETUP for automatic Asterisk and Zaptel configuration building Also the Astribank PRI driver initializes the ...

Page 3: ...04 xpp_usb e4e4 1152 Astribank multi FPGA firmware LABEL usb 0000108 CONNECTOR usb 0000 00 03 3 4 XBUS 00 XPD 00 E1_TE Span 1 ZAPTEL SYNC XBUS 00 XPD 01 E1_TE Span 2 XBUS 00 XPD 10 FXS Span 3 XBUS 00 XPD 20 FXS Span 4 Port Type The port_type is the port mode and port function group separated by a comma for example E1 TE or T1 NT Please note that port mode and the function group may be written in a...

Page 4: ...it knows about into logical units called spans A port in an E1 T1 ISDN card is usually a span A whole analog card is also a span You can see the list of spans as the list of files under proc zaptel directory or in the output of the zttool utility XBUS Denotes an Astribank device XPD Basically this is a logical unit of an Astribank device It will be registered in Zaptel as a single span This can be...

Reviews: