background image

 

Operation Manual

 

 

Waste Water Pump

 

51537–51541

 

 
 
 

 

 
 
 
 
 

 

Similar to image, may vary depending on model

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Read and follow the operating instructions and safety information before use.

 

 
 

Technical changes reserved!

 

Due to further developments, illustrations, functioning steps, and technical data can differ slightly.

 

 

Summary of Contents for 51537

Page 1: ...imilar to image may vary depending on model Read and follow the operating instructions and safety information before use Technical changes reserved Due to further developments illustrations functionin...

Page 2: ...ely avoided If you should find a mistake or wish to make a suggestion for improvement we look forward to hearing from you Send an e mail to service wiltec info or use our contact form https www wiltec...

Page 3: ...g the pump An unsecured pressure line can retaliate and thus lead to injuries and or damages Check the hose for wear and damage before every use Ensure that all connections are se cured Occasionally c...

Page 4: ...ion with a fixed pipeline or in stationary position with a flexible pipe Please note The pump should never be installed hanging self supporting of the pressure line or the electricity cable The waste...

Page 5: ...instructions This waste water pump is an approved maintenance free high quality product subject to a strict final inspection We recommend a regular inspection and maintenance to ensure a longer lifesp...

Page 6: ...t To check this place the pump into a container filled with water Carefully lift the float switch by hand and lower it again Then check if the pump switches on and off 2 Ensure that the distance betwe...

Page 7: ...r level depending on the pump variation See the following table Item number Switch on point 51537 120 51538 51539 51540 140 51541 To reassemble the pump to version 2 both screws need to be loosened an...

Page 8: ...d air hose bent Adjust hose Pump does not switch off Float switch cannot sink Place pump properly on the shaft floor Insufficient flow Inlet filter clogged Clean inlet filter Reduced pumping performan...

Page 9: ...1538 51539 51540 51541 Voltage V 230 Frequency 50 Power consumption W 250 400 750 400 750 Max delivery rate h 6000 7000 12500 8000 13000 Max delivery head m 5 5 7 5 8 5 5 7 5 Max immersion depth m 5 8...

Page 10: ...ol lection system for these appliances The logo on the item or on its packaging points out that this item must not be treated as normal household waste but must be disposed of at a recycling collectio...

Reviews: