background image

Relay1 time

(for Relay 1 in B100PROX-MF-SA,RU2, RTT and DINRTT )

Swipe the Master/Admin

finger

8 times

Select relay open time

1 sec

3 sec

5 sec

10 sec

20 sec

30 sec

60 sec

Toggle

Scroll down to select:

OK Beep

Back to MAIN MENU

Blinking row >

BL

BL

BL

BL

BL

BL

BL

BL

Relay2 time

(for Relay 2 in

, DINRTT Remote Relay Unit)

R 2

U

Select relay open time

1 sec

3 sec

5 sec

10 sec

20 sec

30 sec

60 sec

Toggle

Scroll down to select:

OK Beep

Back to MAIN MENU

Blinking row >

BL

BL

BL

BL

BL

BL

BL

BL

Swipe the Master/Admin

finger

9 mes

Tap sensor

Tap sensor

x 9

x 8

Tap sensor

Tap sensor

NOTE:
Swipe UPWARDS
to exit the MENU

Example:
Task: Put Relay1 to stay acvated 10 seconds.

Scroll Master Finger 8 mes, tap, scroll 3 mes, tap,, swipe UP to exit.

20

11.0 B100PROX-MF-SA P

M

ROGRAMMING

ENU

11.9 Set Door Relay Time

This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies
with RoHS directive EN50581:2012

Visual Plus Corporation, s.a.

Drève Richelle 161
WOP G - Bte 34
1410 Waterloo - Belgium

v.b3

1

B100PROX-MF-SA

Standalone Biometric Mifare Reader

USER’S MANUAL

Summary of Contents for B100PROX-MF-SA

Page 1: ...MENU Blinking row BL BL BL BL BL BL BL BL Swipe the Master Admin nger 9 mes Tap sensor Tap sensor x 9 x 8 Tap sensor Tap sensor NOTE Swipe UPWARDS to exit the MENU Example Task Put Relay1 to stay ac...

Page 2: ...dd Administrator 11 7 Delete Administrator 11 8 Settings 11 8 1 Double Swipe Unlocks Door Entry Mode Remote Relay Touch Function 11 8 2 Buzzer Sound Backlight Reset to defaults 11 9 Set Door Relay Tim...

Page 3: ...ace of the TouchChip sensor provides protection from scratching and abrasion due to normal contact with fingertips and any incidental contact with fingernails The reader is capable of working in so ca...

Page 4: ...ia converter and windows application R 485 S 150 mA max 9 14 V DC Tricolor Status LED and 4 x Programming LEDs Flush mount IP65 20 C to 50 C 5 to 93 RH without condensation 100 x 94 x 30 N 1 O COM N 1...

Page 5: ...amp Blue Yellow Red Black Pink Violet Orange Gray White PB R 485 S _ 12VDC POWER SUPPLY _ NC COM GND PB PB _ Electro Magnetic Lock Green Blue Yellow Red Black Pink Violet Orange Gray White Green Colou...

Page 6: ...sensor UP to exit the programming menu Navigate the Programming Menu Exit the Programming Menu 6 6 0 R S T ECOMMENDED WIPING ECHNIQUE 6 1 Taping the sensor 6 2 Scrolling the sensor up and down 7 0 IN...

Page 7: ...r Groups With the Quick programming feature the Users are assigned in Group 1 or Group 2 For most of the installations 2 groups are enough and can be used as Group 1 for permanent residents Group 2 fo...

Page 8: ...When using proximity reader for Finger Or And Card Mode first present the Card then swipe the finger min 6 times With this the quick programming is completed The system is now operational with default...

Page 9: ...the Reader in Finger ON Card mode Follow the procedure on page 16 17 1 Swipe the Master or Admin Finger twice 2 Swipe the user finger min 6 times until Ok Beep 3 Present the Card and hold it in the p...

Page 10: ...stand activation in longer periods 12 VDC 1N4007 RTT Black Red Pink Violet Black Brown Pink Violet Red White Yellow COM NO GND 12V out A RS485 B RS485 B100PROX MF SA Black Red Pink Violet B R 48 5 S 1...

Reviews: