background image

外部面板

內部面板

Press and hold the "

SET

" button, and in five seconds you will 

hear "

Du...Du...Du...DuDu

", release the button, voice prompt

 "

successfully

", represents reset Ok, then release the "SET" 

butto

.

Factory default administrator PIN Code is 

123456

Note: After initializing, any CARD or factory default PIN code 

           123456 can unlock.

Register administrators

Press "SET" button  or  press "*"  then "#" keys to activate the

setting mode.

Voice broadcast: "

Add administrator

", Please enter card

 or PIN code to add.

Register Users

Touch lights up the keyboard, press " 

*

 " and then "

";

Or short press the " 

SET

 " button, voice broadcast:

 "Please verify admin" and then enter the administrator

 information

Modification

Delete user information

Touch lights up the keyboard, press " 

*

 " and then " 

#

 ";

Or short press the " 

SET

 " button, voice broadcast:

 "

Please verify admin

" and then enter the administrator

 information

2.1

2.2

3.1

Enter a new PIN code (6 to 12 digits) and then press “ # ”or 

swipe the RF card.

Note: The lock will exit the setting mode after 12 seconds

            if no operation or press “ * ” key  to exit the setting mode.

           Factory default PIN code 123456 will be invalidated after 

           Administrator  registration completed.

Voice broadcast after verification

"

1 Add User   2 Delete User   3 Lock Settings   4 Add Admin

"

Press 1 to enter the Add User according to Voice guide. 

Enter a PIN code or card to enter user information

Note: 1.The lock will exit the setting mode after 12 seconds

               if no operation or press “ * ”  key to exit the setting

               mode.

            2.Repeated registered -PIN code is not allowed. 

Voice guide after verification

"1 

Add User   2 Delete User   3 Lock Settings   4 Add Admin

"

Press 2 to enter the Delete User state and voice

broadcast:"

Delete user

"

Swipe the key card or enter the user number or PIN code

 on the keyboard sensor area, press "

#

" to confirm the input, 

and then press "#" to confirm the deletion.

Note: The lock will exit the setting mode after 12 seconds if no 

            operation or press “ * ” key  to exit the setting mode.

Delete all user information

According to operation 3.1, enter the delete user state 

and enter 000#.

Voice broadcast "DuDu" and then press " 

#

 " to confirm 

deleting all users.

3.2

Note: 1.The lock will exit the setting mode after 12 seconds

               if no operation or press “ * ”  key to exit the setting

               mode.

           2.After all deletion, only users are deleted, not admini-

              strators.

Add administrator

Touch lights up the keyboard, press " 

*

 " and then " 

#

 ";

Or short press the set button, voice broadcast:

 "

Please verify admin

" and then enter registered administrator 

 PIN code.

2.3

Voice broadcast after verification

"

1 Add User   2 Delete User   3 Lock Settings    4 Add Admin

"

Press 4 to enter the Add Admin state and voice 

broadcast:"

add admin

"

Enter a PIN code or card to enter administration information

.

Note: Maximum 9 administrators can be saved.  

            The administrator has the authorization to enter to Setting 

            mode and open door.

Usage

Open Door by PIN Code

 

4.1

Touch the keypad. Enter 6~16 digits (PIN code and fake PIN 

code) and press “ 

” to confirm. The confirmation sound will 

be heard if the PIN code is correct. Then turn lever to open the 

door within 8 seconds. After that, The confirmation sound will 

be heard again and door will be locked.

(Fake PIN code can input before and after the PIN code.)

The RED light will ON and a voice prompt will be heard if PIN 

code is NOT matched.

( RED light will be ON and the  system will lock for 1 minute 

 after 5 consecutive  failed try by key card/PIN code.)

Open Door by KeyCard

 

4.2

Touch the keypad. Swipe the KeyCard on keypad induction 

zone. Then turn lever to open the door within 8 seconds.

The RED light will ON and a voice prompt will be heard if the 

key card is NOT matched.

( RED light will be ON and the  system will lock for 1 minute 

  after 5 consecutive  failed try by key card/PIN code.)

Ver1.04

Factory Reset

1.3

Start Up

"

successfully

" will be heard after successful registration.

Entry door lock setting

 lock setting

Voice broadcast after verification

"

1 Add User   2 Delete User   3 Lock Settings   4 Add Admin

"

Press 3 to enter the Lock Setting state.

Voice broadcast:

"

1 Function Settings  2 Volume Setting  3 Language Settings

"

Verification

administrator

1  Add User

2 Delete User

3 Lock 

  Settings

4 Add Admin

1 Function 

  Setting

2 Volume

   Setting

3 Language

  Setting

1 Enable Passage
2 Enable Dual Verify
3 Enable Mute

1 Volume Up
2 Volume Down

1 Chinese
2 English

Before Installation

Preparation

Door Preparation

● 

54mm hole saw

● 

25mm hole saw

● 

Fixing

●    

 

Screwdriver

●  

Drill

Key x 3

M4 Machined

Screw x 3

M4 Wooden

Screw x 4 

Spring

Latch

KeyCard x 2

Outside Panel

Inside Panel

Alkaline Batteries
(AAA x 4)

All dimensions in millimetres

Yale EC800 Smart Lock

USER MANUAL

Comp

on

ents

1.1

1.2

Spindle

Chisel and hammer

Strike

Dust Box

Summary of Contents for EC800

Page 1: ...e saw 25mm hole saw Fixing Screwdriver Drill Key x 3 M4 Machined Screw x 3 M4 Wooden Screw x 4 Spring Latch KeyCard x 2 Outside Panel Inside Panel Alkaline Batteries AAA x 4 Yale EC800 Smart Lock USER MANUAL Components 1 1 1 2 Spindle Chisel and hammer Strike Dust Box ...

Page 2: ...l hear Du Du Du DuDu release the button voice prompt successfully represents reset Ok then release the SET butto Factory default administrator PIN Code is 123456 Note After initializing any CARD or factory default PIN code 123456 can unlock Factory Reset 1 3 ...

Page 3: ...r a new PIN code 6 to 12 digits and then press or swipe the RF card Note The lock will exit the setting mode after 12 seconds if no operation or press key to exit the setting mode Factory default PIN code 123456 will be invalidated after Administrator registration completed Start Up successfully will be heard after successful registration All dimensions in millimetres ...

Page 4: ...mation 2 2 Voice broadcast after verification 1 Add User 2 Delete User 3 Lock Settings 4 Add Admin Press 1 to enter the Add User according to Voice guide Enter a PIN code or card to enter user information Note 1 The lock will exit the setting mode after 12 seconds if no operation or press key to exit the setting mode 2 Repeated registered PIN code is not allowed ...

Page 5: ...nistrator PIN code 2 3 Voice broadcast after verification 1 Add User 2 Delete User 3 Lock Settings 4 Add Admin Press 4 to enter the Add Admin state and voice broadcast add admin Enter a PIN code or card to enter administration information Note Maximum 9 administrators can be saved The administrator has the authorization to enter to Setting mode and open door ...

Page 6: ...de after verification 1 Add User 2 Delete User 3 Lock Settings 4 Add Admin Press 2 to enter the Delete User state and voice broadcast Delete user Swipe the key card or enter the user number or PIN code on the keyboard sensor area press to confirm the input and then press to confirm the deletion Note The lock will exit the setting mode after 12 seconds if no operation or press key to exit the setti...

Page 7: ... user state and enter 000 Voice broadcast DuDu and then press to confirm deleting all users 3 2 Note 1 The lock will exit the setting mode after 12 seconds if no operation or press key to exit the setting mode 2 After all deletion only users are deleted not admini strators ...

Page 8: ...ct Then turn lever to open the door within 8 seconds After that The confirmation sound will be heard again and door will be locked Fake PIN code can input before and after the PIN code The RED light will ON and a voice prompt will be heard if PIN code is NOT matched RED light will be ON and the system will lock for 1 minute after 5 consecutive failed try by key card PIN code ...

Page 9: ...ypad induction zone Then turn lever to open the door within 8 seconds The RED light will ON and a voice prompt will be heard if the key card is NOT matched RED light will be ON and the system will lock for 1 minute after 5 consecutive failed try by key card PIN code ...

Page 10: ...o enter the Lock Setting state Voice broadcast 1 Function Settings 2 Volume Setting 3 Language Settings Verification administrator 1 Add User 2 Delete User 3 Lock Settings 4 Add Admin 1 Function Setting 2 Volume Setting 3 Language Setting 1 Enable Passage 2 Enable Dual Verify 3 Enable Mute 1 Volume Up 2 Volume Down 1 Chinese 2 English ...

Page 11: ...s 1 according to voice guide 1 Enable Passage 2 Enable Dual Verify 3 Enable Mute Select 1 to turn on the passage mode and voice broadcast 1 Disable Passage 2 Enable Dual Verify 3 Enable Mute To turn off the passage mode select this option to turn it off Note After the passage open mode is turned on the door will keep unlocked state and the door will NOT be automatically locked Press the key to loc...

Page 12: ...sage 2 Enable Dual Verify 3 Enable Mute Select 2 to turn on the Dual Verify mode and voice broadcast 1 Enable Passage 2 Disable Dual Verify 3 Enable Mute To turn off the Dual Verify mode select this option to turn it off 5 1 2 Dual Verify Note In Dual Verify mode the door can only be opened after verifying the success of two users ...

Page 13: ...adcast 1 Enable Passage 2 Enable Dual Verify 3 Enable Mute Select 3 to turn on the Mute mode and voice broadcast 1 Enable Passage 2 Enable Dual Verify 3 Disable Mute To turn off the Mute mode select this option to turn it off Note After the mute mode is turned on the key tone will be cancelled and every unlocked will be muted ...

Page 14: ... Voice guide 1 volume up 2 volume down press 1 volume to increase press 2 to decrease volume Language Setting 5 3 Follow the 5 operation after entering the lock setting press 3 to enter the Language setting according to Voice guide 1 Chinese 2 English press 1 to select Chinese voice prompt press 2 to select English voice prompt ...

Page 15: ...ompts low power indicating that the battery will run out soon Please replace the battery Unlock Indicator 6 2 The unlock indicator light on green when allow to open door by lever KeyCard Induction Zone 6 3 Best position for detecting KeyCard low battery indicator Unlock Indicator KeyCard Induction Zone ...

Page 16: ...In the case of insufficient battery the lock can be powered by USB port at the bottom of the outside panel Press Quick Restart button if the lock is unresponsive Note PIN Code KeyCard remained unchange No response 6 5 Quick Restart ...

Page 17: ...Key Operation 6 6 Press end of the lever to open cover for unlock the door by key even batteries run out Press here ...

Page 18: ...PIN Code 6 10 numerical digits Card Readable Distance 10mm below Battery 4 x AAA alkaline batteries 4 8V below Static Consumption 40uA below Dynamic Consumption 300mA below Operation Temperature 25C 50C Storage Temperature 40C 55C Relative Humidity 10 90 Automatically locking 8s ...