background image

1

P/N

-

-

-

Rev G

YRL EMICL TSINSTL FUL

Retrofitting or modifying this product may impact fire rating, safety features and warranty.

Consult with code specifications to ensure compliance with all codes and ratings.

Yale

 

Assure Lock

®

®

Electronic Interconnected Touchscreen

 

Installation and Programming Instructions

 

(YRC226/YRC426/YRC620

/YRC622

)

®

Network Module

(Optional - Not

available on

YRC620)

Before you begin

for step-by-step installation

instructions & to register

your product

DOWNLOAD

THE BILT APP

4" Touchscreen Shown - 5.5" Available

Inside

of Door

Outside

of Door

Summary of Contents for real Living YRC226

Page 1: ...nce with all codes and ratings Yale Assure Lock Electronic Interconnected Touchscreen Installation and Programming Instructions YRC226 YRC426 YRC620 YRC622 Network Module Optional Not available on YRC...

Page 2: ...2 P N Rev G YRL EMICL TSINSTL FUL Before You Begin 1 3 8 35mm Min to 1 3 4 44 5mm Max 4 1 2 114 Min x1 x2 x8 Network Module Optional Not available on YRC620 3 32 1 8 Template x2 x2 x2 2 1 8 2 1 8 1 1...

Page 3: ...3 P N Rev G YRL EMICL TSINSTL FUL Mark Door Reference Lines C L REMOVE Template EXISTING 2 3 8 or 2 3 4 Backset...

Page 4: ...4 P N Rev G YRL EMICL TSINSTL FUL 1 Preparing Door if necessary Drill holes 1 2 way thru door then complete from other side to prevent splitting 2 1 8 2 3 8 or 2 3 4 1 Template 4 or 5 5...

Page 5: ...5 P N Rev G YRL EMICL TSINSTL FUL 2 Installing Strike Plates Door Frame Inside of Door Frame 1 Dia x 1 Deep 1 Dia x 1 2 Deep Frame 7 16 8 32 x 1 UNCWS x4...

Page 6: ...d Right Hand Hinges Right RH Open Inward Right Hand Reverse Hinges Right RHR Open Outward The hand of a door is determined from the secure side of the door The term secure means the side from which yo...

Page 7: ...G YRL EMICL TSINSTL FUL 3 Changing Handing if necessary 4 24 x 1 4 PPHMS 4 Left Hand to 4 Right Hand Shown x2 3 DO NOT TAMPER WITH OR LOOSEN E CLIP AND ITS ASSEMBLY DO NOT LOOSEN THESE 6 SCREWS OR REM...

Page 8: ...Changing Handing if necessary continued 3 8 P N Rev G YRL EMICL TSINSTL FUL...

Page 9: ...Rev G YRL EMICL TSINSTL FUL Lockset Handing Configurations 4 Left Hand For 5 5 For 4 4 Right Hand For 5 5 For 4 After handing is changed check that lever and thumbturn rotate freely Test Lever and Thu...

Page 10: ...10 P N Rev G YRL EMICL TSINSTL FUL 4 Installing Fire Cups Inside of Door Both Fire Cups and a marked UL Latchbolt must be used to qualify for listing UL...

Page 11: ...11 P N Rev G YRL EMICL TSINSTL FUL 5 Adjusting Deadbolt Latch If adjustable deadbolt latch provided O optional default UP 2 3 8 position UP 2 3 4 position Press Pull...

Page 12: ...atch Latchbolt x4 7 16 8 32 x 1 UNCWS Curved edge of latchbolt faces direction door closes Choose latchbolt based on backset 2 3 8 or 2 3 4 Inside of Door Bolt must be in retracted unlocked position b...

Page 13: ...13 P N Rev G YRL EMICL TSINSTL FUL M6x55 PPHMS UP Inside of Door x2 7 Installing Exterior Deadbolt UP Bolt must be in retracted unlocked position...

Page 14: ...14 P N Rev G YRL EMICL TSINSTL FUL 8 Installing Lock Chassis 10 32 x 1 1 2 PPHMS Inside of Door x2 UP...

Page 15: ...5 P N Rev G YRL EMICL TSINSTL FUL 9 Securing Back Plate to Door x2 6 32 x 1 2 POHMS 6 32 x 1 2 POHMS screws must be used to qualify for listing UL Drill two pilot holes 1 8 x 1 2 deep Inside of Door U...

Page 16: ...16 P N Rev G YRL EMICL TSINSTL FUL Testing Deadbolt Latchbolt Operation Outside of Door...

Page 17: ...17 P N Rev G YRL EMICL TSINSTL FUL 10 Remove Battery Cover Loosen screw to remove cover...

Page 18: ...ching the Cable Assembly Cable must be routed as shown to avoid interference with movement of lock UP Inside of Door Align wire connectors so that tabs slide into slots Tug gently on cables to test th...

Page 19: ...19 P N Rev G YRL EMICL TSINSTL FUL 12 Installing Interior Lock Turn thumbturn to adjust slot orientation UP Orientation must match Do not fasten lock to back plate until properly fitted Inside of Door...

Page 20: ...20 P N Rev G YRL EMICL TSINSTL FUL 12 Installing Interior Lock continued 10 32 x 5 8 POHMS x1 6 32 x 1 PPHMS x2 Inside of Door DO NOT LOOSEN THIS SCREW...

Page 21: ...21 P N Rev G YRL EMICL TSINSTL FUL Pull lever to ensure it is secure 13 SNAP Installing Interior Lever Inside of Door Inside of Door...

Page 22: ...22 P N Rev G YRL EMICL TSINSTL FUL Testing Final Latchbolt Operation Outside of Door Inside of Door...

Page 23: ...Testing Final Deadbolt Operation If testing fails go back to beginning of Step 12 and check installation 23 P N Rev G YRL EMICL TSINSTL FUL...

Page 24: ...module with batteries in unit Damage may occur Bolt must be in retracted unlocked position before installing batteries Tighten screw to replace cover Welcome to 15 Installing Batteries Cover Optional...

Page 25: ...ng Instructions After entering the Master code PIN Press Advanced Lock Settings Press to Select Press Handing the Lock Press to Select Press to complete Lock will cycle motor to complete handing Congr...

Page 26: ...ify proper door preparation and re bore holes that are too small or misaligned d Verify touchscreen wire harness is routed properly see Step 10 e Verify bolt is installed with correct side up see Step...

Page 27: ...es and insert a small screwdriver into the hole holding the reset button for 3 seconds 4 While still holding the reset button insert the 4th battery and hold the reset button for an additional 3 secon...

Page 28: ...Speaker P Key Return to Previous Low Battery Indicator Lockout Mode Touchscreen OR Master Code must be created before any further programming PIN Max User Codes 250 with Z Wave Plus or ZigBee network...

Page 29: ...lation or after PIN resetting the lock to factory default Programming and use of lock is not possible until this step has been successfully completed Press Press Register Master Code Press the gear ke...

Page 30: ...e or ZigBee network module Max user codes 25 without network module or with iM1 network module Max user codes 12 with Bluetooth Enter 4 8 digit code PIN Press Press code flashes Press Enter 4 8 digit...

Page 31: ...y other PIN programming of the lock Factory Setting Registration required Disabled Disabled Off Enabled Enabled Low 5 Times 60 Seconds Settings Master Code PIN Automatic Re lock Inside Indicator Light...

Page 32: ...e Setting With the optional Network Module installed this setting becomes available thru the Main Menu 7 and allows the lock to connect with a network controller One Touch Locking When the latch is re...

Page 33: ...the lock PIN M U This function appears only with network module installed Default settings in bold Master Code Setting PIN User Code Registration PIN Continue Complete Register Delete Continue Comple...

Page 34: ...M U Default settings in bold Master Code Setting PIN User Code Registration PIN Continue Complete Register Delete Continue Complete M 2 3 1 Enable Disable English Spanish French Silent Low High Compl...

Page 35: ...35 P N Rev G YRL EMICL TSINSTL FUL Programming Troubleshooting Symptom Suggested Action...

Page 36: ...ase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radi...

Page 37: ...llow the instructions included with it Removing a Yale Z Wave Plus Smart Module from your Assure Lock Z Wave System 1 Install the Yale Smart Module into the slot above the battery compartment IMPORTAN...

Page 38: ...e d interf rence aux autres utilisateurs le type d antenne et son gain doivent tre choisies de fa on que la puissance isotrope rayonn e quivalente PIRE ne d passe pas ce qui est n cessaire pour une co...

Page 39: ...eadbolts YRD216 ZW3 YRD226 ZW3 YRD256 ZW3 YRC216 ZW3 YRC226 ZW3 YRC256 ZW3 YRD652 ZW3 NF YRD622 ZW3 NF YRD612 ZW3 YRC652 ZW3 NF YRC622 ZW3 NF YRC612 ZW3 YRD622 ZW3 YRD642 ZW3 YRC622 ZW3 YRC642 ZW3 YRD...

Page 40: ...s Security Version 1 9 Command Class Security 2 Version 1 9 Command Class Device Reset Locally Version 1 9 Command Class Power Level Version 1 10 Command Class Version Version 3 10 Command Class Batte...

Page 41: ...lication Status Version 1 28 Command Class Transport Service Version 2 28 Command Class Supervision Version 1 28 Command Class Indicator Version 3 28 Command Class Basic Version 2 29 This command clas...

Page 42: ...t ID description in the Command Class Manufacturer Specific section 1 4 Made the following updates Added interconnected locks YRC216 YRC226 YRC256 Added configuration parameter 28 expiration time to t...

Page 43: ...me app via smartphone or tablet and follow the in app prompts to add a new device SmartStart works when the Z Wave system has the DSK saved and one of the following are true o The lock has the minimum...

Page 44: ...e to the user code database and configuration settings will be retained as opposed to set back to defaults Factory Reset Factory resetting the lock with the Z Wave module installed will clear the Z Wa...

Page 45: ...elease Dec 2021 BCD Command Class Z Wave Plus Info Version 2 The Z Wave Plus Info command class reports the following information Role Type Slave Sleeping Listening 0x07 Node Type Z Wave Plus Node 0x0...

Page 46: ...YRD642 ZW3 2nd Generation Fire Rated Keyless Touch Screen Deadbolt 0x52C2 for YRC622 ZW3 2nd Generation Fire Rated Keyed Interconnected Touch Screen Deadbolt 0x52C4 for YRC642 ZW3 2nd Generation Fire...

Page 47: ...he Z Wave Specification Command Class Device Reset Locally Version 1 This command class requires security The Yale door locks covered in this guide can be reset to their factory default settings by ma...

Page 48: ...be used once the lock is enrolled successfully Command Class Version Version 3 This command class requires security The Yale Real Living locks are a multi processor system with 1 additional firmware...

Page 49: ...battery level is reached starting at about 3 8V for Product Type IDs 0x8002 0x8004 and starting at about 4 2V for Product Type ID 0x8109 0x810A 0x8103 0x8104 In addition the Yale Locks provide 2 earli...

Page 50: ...ication Command Class Schedule Entry Lock Version 3 This command class requires security Yale locks support Year Day Schedule types and Daily Repeating Schedule types Yale locks allow the controller t...

Page 51: ...e lock s operation mode called User Code Keypad Mode in this command class can be modified through Version 2 of this command class or through parameter 8 of the Configuration command class This is the...

Page 52: ...ess to the user Instead it generates an alarm to the Lifeline and does NOT take preventative actions for further attempts to enter the User ID and or User Code 0x04 0x04 One Time Use This PIN is disab...

Page 53: ...the user Instead it generates an alarm to the Lifeline and does NOT take preventative actions for further attempts to enter the User ID and or User Code 0x03 0x03 One Time Use This PIN is disabled im...

Page 54: ...ameters in the lock anytime the lock loses power Even though the Time CC is not secure the Time Set command must be issued at the same or higher security level as when the device was enrolled in order...

Page 55: ...egion but this will also be 0 for now since there is only a single build of firmware Table 4 Region Specific Values for Firmware ID 0 Upper Nibble Region Value ANZ 0x1 CN 0x2 EU 0x3 HK 0x4 IL 0x5 IN 0...

Page 56: ...Screen interface 3 minutes For YRC D652 ZW3 NF YRC D622 ZW3 2nd Generation Touch Screen interface 13 minutes For NF YRC D612 ZW3 2nd Generation Push Button interface 13 minutes For YRC D622 ZW3 YRC D...

Page 57: ...mmand_Class Battery o Battery_Report Command_Class_Configuration o Configuration_Report Command_Class_Notification o Notification_Report Command_Class_Door_Lock o Door_Lock_Operation_Report o Door Loc...

Page 58: ...sholds Any manual keypad Lock Operation when lock is under the battery thresholds or Power Cycle Lock Door Lock Operation Report Manual or Keypad Unlock Lock Door Lock Configuration Report Door Lock C...

Page 59: ...while locking 0x06 0x0B 0x02 Deadbolt jammed while unlocking 0x06 0x0B Keypad Lock 0x12 0x 01 max users Where Alarm level represents user slot number 0x06 0x05 Keypad Unlock 0x13 0x 01 max users Wher...

Page 60: ...eleted Alarm level user slot number 0x06 0X0D single 0X0C all Door State 0x23 0x00 Door is open 0x06 0x16 0x01 Door is closed 0x06 0x17 Non Access 0x26 0x 01 max users A Non Access Code was entered at...

Page 61: ...d The lock simply denies it and plays the Denied Trying to duplicate the master code will result in a 0x71 0x00 alarm report 0x06 0x0F Disabled user entered at keypad 0x83 0x 01 max users A disabled u...

Page 62: ...Lock 0x06 0x03 0x0001 Integrated BLE Auto Relock 0x06 0x03 Integrated BLE Unlock 0xE3 0x0000 Integrated BLE Unlock 0x06 0X04 0x0001 Integrated BLE Auto Unlock 0x06 0X04 Homekit BLE Lock 0xE4 0x0000 In...

Page 63: ...Volume 0x03 Silent 0x02 Low Volume 0x8002 0x8109 0x8103 Set Volume Level to high 1 low 2 or silent 3 0x8002 0x8109 0x8103 0x8104 53 0x01 High Volume 0x810A 0x8004 0x8104 Set Volume Level to high 1 or...

Page 64: ...Adjust the time your lock is shut down after reaching its wrong code entry limit 81 8 Operating mode 1 byte 0x00 Normal Mode 0x02 Privacy Mode 0x8002 0x8004 0x8109 0x810A 0x00 Normal Mode Set the Ope...

Page 65: ...Set Lock Status LED feature to enable or disable 49 16 Escape Return Mode 1 byte 0x00 Disable 0xFF Enable 0x00 Disable Enable or Disable Escape Return Mode 36 21 Eco Mode On Off 1 byte 0x00 Disable 0x...

Page 66: ...OFF ON YRC D226 256 652 622 642 NF YRC D622 YRD410 420 430 450 Numbers 0 9 on Touch Screen Flash YRC D216 NF YRC D612 All buttons Flash Inside LED Flashes In order to set the Indicator ID 0x50 with P...

Page 67: ...or Lock Operation Report Door Lock Mode 0x00 The Basic Get Current Value Basic Get Duration and Basic Get Target Value are mapped to Door Lock Operation Get and Basic Set is directly mapped to Door Lo...

Reviews: