Yale Real Living Key Free Touchscreen Deadbolt

®

Installation and Programming Instructions

®

Summary of Contents for Real Living YRD240

Page 1: ...Rev E x4 x2 x3 8 32 x 5 16 Machine screws 7 wood 8 32 machine x 20mm Combination screws M6x47mm Long through bolt Optional Network Module Yale Real Living Key Free Touchscreen Deadbolt Installation and Programming Instructions ...

Page 2: ...2 P N AYRD 240 INST FUL Rev E Preparing Door ...

Page 3: ...N AYRD 240 INST FUL Rev E O x4 1 d faut e 2 3 8 position 2 3 4 position Installing Latch Strike Plate Press Pull optional Bolt must be in retracted unlocked position Note horizontal orientation of mechanism ...

Page 4: ...4 P N AYRD 240 INST FUL Rev E 2 Installing Touchscreen Escutcheon Outside of Door Inside of Door Bolt must be in retracted unlocked position Note horizontal orientation of mechanism ...

Page 5: ...5 P N AYRD 240 INST FUL Rev E x2 3 Installing Interior Mounting Plate Loosen screw to remove cover ...

Page 6: ...4 Attaching the Cable Assembly 6 P N AYRD 240 INST FUL Rev E ...

Page 7: ...7 P N AYRD 240 INST FUL Rev E x3 5 Installing Interior Escutcheon ...

Page 8: ...8 P N AYRD 240 INST FUL Rev E Bolt must be in retracted unlocked position before installing batteries 3 Testing Operation ...

Page 9: ... E Installing Batteries Handing the Lock Batteries must be removed prior to removing and or inserting network module Installing Optional Network Module Welcome to Yale Real Living Lock automatically adjusts for proper handing 6 7 ...

Page 10: ...0 INST FUL Rev E Tighten screw to replace cover Congratulations you ve installed the Yale Real Living Key Free Touchscreen Deadbolt Continue with Programming Instructions to customize your product 8 Installing Cover ...

Page 11: ...or Lockout Mode Failsafe 9 volt Battery Connection Use Alkaline battery Exterior Escutcheon Programming Instructions OR Master PIN Code must be created before any further programming Max User Codes 250 with Network Module Max User Codes 25 without Lock Activation 11 P N AYRD 240 INST FUL Rev E ...

Page 12: ...stallation or after resetting the lock to factory default Programming and use of lock is not possible until this step has been successfully completed Press Press Register Master Code Press the pound key to continue Enter a 4 to 8 digit PIN code followed by the pound key Registered 12 P N AYRD 240 INST FUL Rev E ...

Page 13: ...Max user codes 250 with Network Module Max user codes 25 without Press Enter User number 1 25 or 1 250 Press Adding more User Codes Enter 4 8 digit PIN code Press To end programming Enter 4 8 digit PIN code Press code flashes Press Menu Mode enter number press the pound key to continue 13 P N AYRD 240 INST FUL Rev E ...

Page 14: ...ode Press PIN Code Management With Network Module Up to 250 Users Duplicate if necessary User Name User PIN Code Master User ___ User ___ User ___ User ___ User ___ User ___ Code Chart User ___ User ___ User ___ User Type User ___ User ___ User ___ User ___ User ___ User ___ ...

Page 15: ...en lock is reset to factory defaults all user codes including the Master PIN code are deleted and all programming features are reset to original default settings see below 1 Remove the battery cover and batteries 2 Remove the interior escutcheon to access the reset button 3 The reset button see image at right is located above the PCB cable connector 4 While pressing the reset button minimum of 3 s...

Page 16: ...k Network Module Setting With the optional Network Module installed this setting becomes available thru the Main Menu 7 and allows the lock to connect with a network controller One Touch Locking When the latch is retracted activating the keypad will extend the latch during Automatic Re lock duration or when Automatic Re lock is disabled When One Touch Re lock is in use any not disabled valid PIN c...

Page 17: ...tings Volume Setting Language Setting Mode Lockout Mode Network Module Setting Join the Network Enable Disable Exit the Network User Number UN 1 25 without network module 1 250 with network module U This function appears only with RF network module installed Automatic Re lock Enable Disable Inside Indicator Light One Touch Locking Enable Disable Enable Disable Default settings in bold English Span...

Page 18: ...d Check batteries are installed and oriented correctly polarity in the battery case Check batteries are in good condition replace batteries if discharged Check to see if touchscreen harness is fully connected and not pinched Batteries may be completely discharged Batteries do not have enough power Replace batteries Check the door gaps for any foreign objects between door and frame Check that the w...

Page 19: ... small or misaligned d Verify keypad wire harness is routed under the bolt see Fig A e Verify bolt is installed with correct side up Fig A Keypad numerics are scrolling Remove interior escutcheon and check to ensure that the wire harness lies flat against the back recessed area and is properly routed along the side of the escutcheon and tucked under the plastic cable guide Figure A Door is binding...

Page 20: ...es uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful Interference to radio or television reception which can be determined by turning the equipment off and ...