background image

Yale Real Living™

 Push Button Deadbolt

Installation and Programming Instructions

For Technical Assistance call Yale at 1-800-810-WIRE (9473)

NOTE TO INSTALLER

FAILURE TO FOLLOW THESE INSTRUCTIONS
COULD RESULT IN DAMAGE TO THE PRODUCT
AND VOID THE FACTORY WARRANTY

An ASSA ABLOY Group brand

P/N AYRD210-INST-FUL Rev B

This document is available on our website in printed Spanish and French. Go to www.yalerealliving.com.  

Click “Product Information  & Documentation” and then “Installation Instructions”.

Este documento está disponible en español en nuestra página de internet. Vaya a www.yalerealliving.com.  

Presione “Información del Producto y Documentación” y luego “Instrucciones de Instalación”.

Ce document est disponible sur notre site Web dans le français imprimé. Allez à www.yalerealliving.com. 

Cliquez sur le “ ; Information sur le produit et Documentation” et puis “Installation Instructions”.

Summary of Contents for Real Living YRDZW

Page 1: ...lable on our website in printed Spanish and French Go to www yalerealliving com Click Product Information Documentation and then Installation Instructions Este documento est disponible en espa ol en n...

Page 2: ...U4A YRHCPZB0 Zigbee Model s YRDZW YRDZB This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed t...

Page 3: ...lf correctly To reset the lock to factory default see the following The following procedure clears the automatic handing of the lock and returns the lock to programming default deleting all user codes...

Page 4: ...erf rence qui peut causer l op ration peu d sir e For the U4A YRHCPZB0 and 6982A YRHCPZB0 the following statement applies This equipment complies with FCC IC radiation exposure limits set forth for an...

Page 5: ...Instructions Door Marker Outside Escutcheon Bolt Strike Plate Screw Pack Keys Included in the box COMPONENTS AND TOOLS Inside Escutcheon Inside Mounting Plate Battery Cover 4 AA Alkaline Batteries IN...

Page 6: ...om of battery cover 3 Remove the inside mounting plate with gasket from the back door side of the inside escutcheon Battery Cover Inside Escutcheon C The outside escutcheon with gasket remains assembl...

Page 7: ...the outside escutcheon route the cable through 2 1 8 diameter hole Figure 3A INSTALL LOCK Figure 4A Figure 3B Figure 3A 4 Holding the outside escutcheon flush to the door position the inside mounting...

Page 8: ...on PCB as in Fig 6A 6B Figure 6B Figure 7A Figure 6A CAUTION Use care when assembling to ensure that the cable lies against the back recessed area of the inside escutcheon Fig 6A Position and bend cab...

Page 9: ...acy Mode Button Menu and Icons Used in This Guide Cylinder Click the indicated number Enter Master PIN code 4 8 digits in length Factory default 12345678 Press the Star key on the keypad to Enter or A...

Page 10: ...lt is retracted activating the keypad will extend the bolt during Auto Re Lock duration or when Auto Re Lock is disabled Shutdown Time The unit will shutdown for a default of sixty 60 seconds and not...

Page 11: ...number to be registered 1 25 followed by the key 4 Enter a 4 8 digit PIN code for the User number followed by the key Set Up User Codes Note When registering User codes the code must be entered with i...

Page 12: ...tting M M User PIN Deletion Audio Mode All Code Lock out Network Module Setting Enable Enable Register Disable Delete Disable User Number UN 1 25 without network module 1 250 with network module 1 2 U...

Page 13: ...perly aligned and door is free swinging b Check hinges They should not be loose or have excessive wear on knuckles Bolt will not deadlock a Check for sufficient clearance of the bolt within the strike...

Page 14: ...enabled Disable Auto Re lock Mode to lock the door automatically If low battery indicator is lit see below change batteries PIN codes will not register PIN codes must consist of 4 to 8 digits to regis...

Page 15: ...T The batteries must be removed prior to removing and or inserting the network module Remove batteries Remove and or insert network module Reinstall batteries Installing the Network Module Use feature...

Page 16: ...after plastic guide is removed F Remove cylinder by pulling towards the door side of escutcheon Before installing cylinder please be sure you have correct length tailpiece 2 Install new cylinder A Re...

Page 17: ...Network Module Up to 25 Users Location Door Number User User Name User PIN Code User Type User Name User PIN Code Master User 13 User 1 User 14 User 2 User 15 User 3 User 16 User 4 User 17 User 5 Use...

Page 18: ...r ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User...

Page 19: ...ompany Yale is a registered trademark of Yale Security Inc an ASSA ABLOY Group company All rights reserved Yale Real Living is a trademark of Yale Security Inc an ASSA ABLOY Group company Copyright 20...