background image

Doc. No.  APP 079U-03

 

 

 

Pump 125 separate type series 

SH-125B

 MODEL 

No.854592

854594

854596 (SIPHON TYPE) 

DR-125B

 MODEL 

No.854593

854595

854597 (DRUM TYPE) 

SH-125B

-V MODEL 

No.854598

854600

854602 (SIPHON TYPE -V) 

DR-125B

-V MODEL 

No.854599

854601

854603 (DRUM TYPE -V) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

WARNING

 

Prior to operating this pump, be sure to read this operation manual for safety. After reading the manual, 
please keep it at hand any time for your quick reference.

 

 
 

INSTRUCTION 

Summary of Contents for SH-125B Series

Page 1: ...854593 854595 854597 DRUM TYPE SH 125B V MODEL No 854598 854600 854602 SIPHON TYPE V DR 125B V MODEL No 854599 854601 854603 DRUM TYPE V WARNING Prior to operating this pump be sure to read this opera...

Page 2: ...Cautions For safe use of this product be sure to note the following In this document warnings and cautions are indicated by symbols These symbols are for those who will operate this product and for t...

Page 3: ...ating and disassembling the pump Ground connection Make ground connection to pump and peripheral equipment Rapid pumping of material can result in static electrical charge Also be sure to provide prop...

Page 4: ...art until the cause has been identified and corrected Shut off air supply Shut off the air source before installation and piping Install properly Install the unit properly according to the requirement...

Page 5: ...vention measures Take fall prevention measures if using a slim or light tank Risk of falling will be increased due to shift in center of gravity caused by change in the material level in a tank When u...

Page 6: ...mp 4 3 5 Installation of silencer 4 3 6 Connecting the ground wire 4 3 7 Discharge piping 5 3 8 Air piping 5 3 9 Preparation for use 5 4 Operating Method 6 4 1 Operation switch and valve 7 4 2 Solvent...

Page 7: ...up material When compressed air generated by the compressor is fed into the air motor the air switching mechanism built in the air piston actuates vertical reciprocating motions The connecting rod joi...

Page 8: ...rmality discontinue pump operation and refer to Troubleshooting to solve the problem Shut off the air source before installation and piping When installing the pump select an appropriate place and sui...

Page 9: ...drum pump Using a bung adapter DR 125B13 1 Remove a plug on a drum and attach a bung adapter sold separately 2 Insert the pump into the bung adapter Once the lower end foot valve reaches the bottom of...

Page 10: ...tape around the silencer thread to prevent leakage 3 6 Connecting the ground wire WARNING Make ground connection when working with flammable material or in explosive atmosphere Rapid pumping of materi...

Page 11: ...ipe somewhere accessible between the air source and unit 2 Select an air supply hose fitting and air equipment that satisfy the following requirements With these devices connect an air piping and the...

Page 12: ...in personal injury or property damage Be sure to use the unit in accordance with the specifications in this manual Always wear proper safety equipments facemask ear plugs and safety shoes etc when in...

Page 13: ...rom falling over hang the pump with a crane etc or fix container firmly DR type only Material remaining inside or on the surface of the pump may spill out by inserting or removing the pump into from a...

Page 14: ...opriate pressure for each season 4 5 Retightening gland packing V series Because of the deformation or wear of gland packing solvent cup of V series loose the tightness In order to protect plunger and...

Page 15: ...ation immediately when a drum becomes empty Running the pump dry will cause excessive Be especially careful when pumping explosive material Mixture of an air and vaporized material can explode If ther...

Page 16: ...e for the pump and set the pump air regulator knob to 0MPa Without a lubricator Disconnect the air piping from the air inlet of the pump and apply a few drops approx 0 5mL of lubricant directly to the...

Page 17: ...lve is defective wear of seat surface inclusion of foreign material or packings are damaged If downward movement of plunger is faster seat surface of foot valve is defective wear of seat surface inclu...

Page 18: ...6 million cycles 854596 854602 854597 854603 SH 125B13 SH 125B13 V DR 125B13 DR 125B13 V 804859 804863 804860 804864 Plunger 1 per unit 10 million cycles 685795 685795 Packing 1 per unit 5 million cy...

Page 19: ...54600 1 804855 Air motor assembly 1 4 632059 Slit pin 1 5 716409 Bushing 1 6 700350 Cap nut 1 7 716410 Stud 3 8 631918 Wave spring washer 3 9 627045 Nut 3 10 804857 804858 804861 804862 Nut 1 14 80469...

Page 20: ...1 7 716411 Stud 3 8 631918 Wave spring washer 3 9 627045 Nut 3 10 804857 804858 804861 804862 Lower pump assembly 1 12 716288 Joint 1 13 716412 Connecting rod 1 14 804697 Silencer 1 No Part No Descrip...

Page 21: ...Packing 1 10 14 701381 701371 Washer 1 10 15 716413 Stud 1 10 16 716425 716427 Plunger 1 10 17 701382 701369 Cylinder 1 10 18 704742 704744 Chamber 1 10 19 630479 Ball 1 10 21 770493 770208 Packing 2...

Page 22: ...Packing gland 1 10 14 701381 701371 Washer 1 10 15 716413 Stud 1 10 16 716425 716427 Plunger 1 10 17 701382 701369 Cylinder 1 10 18 704742 704744 chamber 1 10 19 630479 Ball 1 10 21 770493 770208 Pack...

Page 23: ...2 704583 704580 Cylinder Suction tube 1 10 13 640012 O ring 1 10 14 632774 Spring pin 1 10 15 627016 Nut 1 10 16 701554 Housing 1 10 17 630334 Ball 1 10 18 701553 Valve seat 1 10 19 770233 Revolving s...

Page 24: ...716433 rod 1 10 12 704583 704580 Cylinder Suction tube 1 10 13 640012 O ring 1 10 14 632774 Spring pin 1 10 15 627016 Nut 1 10 16 701554 Housing 1 10 17 630334 Ball 1 10 18 701553 Valve seat 1 10 19 7...

Page 25: ...t method of A weighted sound pressure level is based on ISO 1996 2 Measurement method of A weighted sound power level is based on ISO 3744 3 Discharge volume per cycle varies according to use conditio...

Page 26: ...20 Dimensions DR 125B3 5 5 SH 125B3 5 5 DR 125B13 SH 125B13 Part No A mm B mm 854592 854594 854598 854600 854593 854595 854599 854601 854596 854602 854597 854603 660 1314 1769 1058 600 1298 840 1115...

Page 27: ...nce curve NOTE Avoid continuous operation if a desired discharge volume is in the shaded area in the right side of each figure SH DR 125B3 5 SH DR 125B3 5 V SH DR 125B5 SH DR 125B5 V SH DR 125B13 SH D...

Page 28: ...cause corrosion inflation or dissolution of the component parts of the product 4 Irregularity arising from repair made by other than by our firm our regional office dealer or authorized service perso...

Page 29: ......

Page 30: ...201810 APP079U Manufactured by YAMADA CORPORATION INTERNATIONAL DEPARTMENT No 1 3 1 Chome Minami Magome Ohta ku Tokyo 143 8504 Japan PHONE 81 0 3 3777 0241 FAX 81 0 3 3777 0584...

Reviews: