background image

EN

 

PM5D system software V1.05 includes the following changes and additions relative to V1.04.

 

Use ENCODER [ON] keys to turn 

 

phantom power (+48V) on/off

 

A “USE ENCODER-ON AS +48V” option has been added 
to the PREFERENCE 1 screen. If this option is on, and HA 
(head amp input sensitivity) is selected as the encoder 
mode, you can use the ENCODER [ON] key located above 
each encoder to turn phantom power supply (+48V) on/
off.

 

Switch parameter value indication 

 

on/off in the Name display

 

A “CHANNEL NAME NUMERIC DISPLAY” field has 
been added to the PREFERENCE 2 screen. In V1.04 and 
earlier, operating the fader or encoder (pan setting) of 
each channel caused the name display to show the value of 
that parameter. In V1.05, turning the “ENCODER 
VALUE” and “FADER VALUE” options off will prevent 
the respective parameter value from appearing when you 
operate the fader or encoder.

 

Select the monitor source from 

 

the panel

 

When selecting a monitor source from the panel in V1.04 
or earlier, you could simultaneously select one source from 
[2TR A1]–[2TR D3] or [DEFINE] and one source from 
[STEREO A]/[STEREO B] (including LCR), for a 
maximum total of two sources. In V1.05, turning on one 
key will turn off the other keys, allowing you to select a 
single monitor source more rapidly. If you want to select 
two sources simultaneously (as in V1.04 and earlier), press 
the corresponding panel keys simultaneously, or use the 
MONITOR screen.

 

HA follows Recall Safe on/off 

 

operations

 

A new SAFE KEY MODE SELECT section has been added 
to the RECALL SAFE screen. If you turn on the HA+CH 
button, using the [RECALL SAFE] key of the panel or the 
RECALL SAFE button in the CH VIEW screen (INPUT 
VIEW function) to turn Recall Safe on/off will now also 
turn on/off the Recall Safe setting for the HA patched to 
the corresponding channel. If the CH button is on, the HA 
Recall Safe setting will not be linked.

 

DCA group name Recall Safe and 
Selective Recall can be switched 

 

on/off

 

A new WITH NAME button has been added to the DCA 
area of the RECALL SAFE screen and SELECTIVE 
RECALL screen. This allows you to exclude just the DCA 
group name from DCA group Recall Safe and Selective 
Recall. If the WITH NAME button is on, Recall Safe and 
Selective Recall will apply to the DCA group names of 
DCA groups for which these functions are on. If the 
WITH NAME button is off, DCA group names are 
excluded from Recall Safe and Selective Recall.

 

PLUG-IN parameters added to 

 

Recall Safe and Selective Recall

 

PLUG-IN parameters have been added to the RECALL 
SAFE screen and SELECTIVE RECALL screen. This is to 
support plug-in cards (such as Waves Y96K) that will 
become available in the future.

PM5D V1.05 Supplementary Manual

PM5D V1.05_E Page 1 Thursday, September 30, 2004 10:29 AM

Reviews: