background image

                                            

Yaskawa Electric America, Inc. – www.drives.com 

IG.AFD.61, Page 1 of 6 

Date: 07/01/04, Rev: 04-07 

Dual Encoder Feedback Option Card

PG-W2

1. Part Number: 

 PG-W2.

 

 
2. Applicability:

  F7, G7, GPD515/G5. 

 

3. Introduction:

  The PG-W2 dual encoder feedback option card supports two encoder (pulse train) inputs and one pulse train 

output. The terms encoder, PG (pulse generator), and pulse train are used interchangeably in this guide. The PG-W2 can be 
used for the standard software function “Motor 2 Selection” or with several custom (CASE) software titles. The specific custom 
(CASE) software installed in the drive determines the exact functionality of the two encoder inputs and pulse train output.  The 
PG-W2 card is mounted on the drive’s control board as shown in Figure 1.  The following example illustrates how the PG-W2 
is used in conjunction with Electronic Lineshaft software: 

Input 1:  Follower encoder used for Electronic Lineshaft control and for vector control of the follower motor. 
Input 2:  Master encoder (pulse train) source used for Electronic Lineshaft control. 

 

Output:  Selectable from either input to be used for other followers. 

 

4. Receiving:

  All equipment is tested against defect at the factory.  Report any damages or shortages evident when the 

equipment is received to the commercial carrier who transported the equipment. 
 

5. Cautions:

 

a.  Hazardous voltage can cause severe injury or death. Lock all power sources feeding the drive in the “OFF” position. 
b.  This option card uses CMOS IC chips.  Use proper electrostatic discharge (ESD) protective procedures when 

handling the card to prevent I.C. damage or erratic drive operation. 

c. 

If other option cards are to be installed at the Option C (2CN) or Option D (3CN) positions (See Figure 2), their 
installation and wiring should be completed before installation of the PG-W2 card. 

d. 

Before installing the PG-W2, a technically qualified individual, who is familiar with this type of equipment and the 
hazards involved, should read this entire installation guide.

 

 

Figure 1.  PG-W2 Dual Encoder Feedback Card  

Figure 2.  PG-W2 Option Card installation 

Summary of Contents for PG-W2

Page 1: ...or control of the follower motor Input 2 Master encoder pulse train source used for Electronic Lineshaft control Output Selectable from either input to be used for other followers 4 Receiving All equipment is tested against defect at the factory Report any damages or shortages evident when the equipment is received to the commercial carrier who transported the equipment 5 Cautions a Hazardous volt...

Page 2: ...etween the PG W2 card and the encoder the master drive and or external monitoring circuits Observe the following a The need for the marker Z C channel depends on the installed custom CASE software Standard software does not use the marker pulse b Keep the PG W2 i e control circuit wiring separate from main circuit input output wiring A separate metallic grounded conduit with ONLY the PG wiring run...

Page 3: ...Same as Terminals 16 23 10 A2 11 A2 A Channel 12 B2 13 B2 B Channel 14 Z2 15 Z2 Z C Channel Encoder Input 2 Line Driver Signal Level 16 Shield Shield Drain for Encoder Wiring Same as Terminals 9 23 17 AM 18 AM A Channel 19 BM 20 BM B Channel 21 ZM 22 ZM Z C Channel Pulse Monitor Output RS 422 Signal Level 23 Shield Shield Drain for Encoder Wiring Same as Terminals 9 16 24 IG5 Pulse Monitor Termina...

Page 4: ...Yaskawa Electric America Inc www drives com IG AFD 61 Page 4 of 6 Date 07 01 04 Rev 04 07 Dual Encoder Feedback Option Card PG W2 Figure 4 PG W2 Interconnection Diagram ...

Page 5: ...n be utilized to power that encoder However if the current draw from the PG W2 s power supply exceeds 200mA provide a separate power supply as shown in Figure 5 If the momentary power loss ride thru function of the drive is to be used include a backup capacitor in the PG power wiring or take other necessary precautions 15 Maximum Input Frequency The maximum input frequency of the PG W2 card is 300...

Page 6: ...gnal A will lead signal B by 90 o If any one of the four signals is missing the drive cannot accurately measure the encoder rotation speed or direction 17 Viewing Signals With An Oscilloscope The PG W2 option card has test points that can be used to connect an oscilloscope Figure 1 shows the locations of the test points on the PG W2 card Test points TP3 through TP8 are after the compliment is subt...

Reviews: