background image

English

993D

Statement: The company reserves the right to improve and upgrade products, 
product specifications and design are subject to change without notice.

Thanks for purchasing this intelligent rework station, this product is specifically 
designed for lead-free welding, please read instructions carefully before using. 
After reading, please keep it for future reference.

INSTRUCTION

 

MANUAL

   

High-power 

Touch-screen rework station

Summary of Contents for 993D

Page 1: ...design are subject to change without notice Thanks for purchasing this intelligent rework station this product is specifically designed for lead free welding please read instructions carefully before using After reading please keep it for future reference INSTRUCTION MANUAL High power Touch screen rework station ...

Page 2: ... flammable materials Never use this device for extended periods in the same location 4 Be aware that heat may be transferred to distant flammable materials Someone must be present at all times while the device is connected 5 This device is not intended to by operated by individuals with diminished physical sensory or mental capacities or by those who lack experience such as children except in the ...

Page 3: ...le back in the holder The rework station will automatically cut off power to the heating wire and enter the cooling heating element mode When the temperature is below 100 C the display shows air flow is stopped and the rework station enters standby mode 7 The power switch should be switched off if the rework station is not used for a long period of time 1 Turn on the power switch and set the tempe...

Page 4: ...ion 11 Please replace with the same model of heating element or heating core Special Note Hello dear user Because the machine air gun and the soldering iron handle use high strength stainless steel tube in the production process the machine must go through inspection or calibration four times under normal working conditions The cylinder will turn slightly yellow due to high temperature When the ne...

Page 5: ...le back in the holder The rework station will automatically cut off power to the heating wire and enter the cooling heating element mode When the temperature is below 100 C the display shows air flow is stopped and the rework station enters standby mode 7 The power switch should be switched off if the rework station is not used for a long period of time 1 Turn on the power switch and set the tempe...

Page 6: ...nsor wire should be opposite the ground lead of the steel pipe The red and yellow heat shrink tube is the sensor wire 5 Insert the installed heating core element into the internal frame of the handle and tighten the set screw The heating element connector of the heating core must be inserted in place Connect all the cables well as shown in the diagram and set the cable tie The sensor wire has pola...

Page 7: ...7 5x17 5 0 68x0 68 44 needle A1135 PLCC 20x20 0 78x0 78 52 needle A1136 PLCC 25x25 0 98x0 98 68 needle A1137 PLCC 30x30 1 18x1 18 84 needle A1138 PLCC 12 5x7 3 0 49x0 49 18 needle A1139 15 15 0 59 0 59 A 18 5 0 73 B 18 5 0 73 19 0 75 19 0 75 A 21 0 83 B 21 0 83 24 0 94 A 26 1 02 B 26 1 02 A 26 1 02 B 26 1 02 29 1 14 6 9 0 27 10 0 39 10 0 39 PLCC 11 5x11 5 0 45x0 45 28 needle A1140 PLCC 11 5x14 0 4...