background image

IM 12J06K04-E-E

6th edition

Instruction 

Manual

Models FD30 / PB30
Fittings for the DO30G

Summary of Contents for FD30

Page 1: ...IM 12J06K04 E E 6th edition Instruction Manual Models FD30 PB30 Fittings for the DO30G...

Page 2: ...f the immersion fitting 6 5 2 1 Checklist 6 5 2 2 Preparing the immersion fitting 7 5 2 3 Mounting the sensor in the immersion fitting 7 5 2 4 Mounting the sensor cleaner JC option 7 5 3 Installing th...

Page 3: ...Option for convenient mounting Model PB30 Designed for minimal user maintenance Good flow of sample at the membrane due to wave action and constant ball movement Constant measurement depth Standard eq...

Page 4: ...ified and disinfected prior to shipment for the health and safety of our employees Material Safety Data sheets must be included for all components of the processes in which the sensors fittings have b...

Page 5: ...ner JC Mounting set MS1 Not available with flanged versions 4 2 Model PB30 Floating Ball Fitting Wetted materials High impact polystyrene PVC Brass Temperature 0 40 C Mounting bracket Galvanized steel...

Page 6: ...ut the sensor mounted to avoid the cable leads becoming wet 5 2 Assembling and mounting of the immersion fitting 5 2 1 Checklist The FD30V27 xx FN fittings will be delivered completely assembled Flang...

Page 7: ...the supplied adhesive Ensure that the sealing will be watertight 5 2 3 Mounting the sensor in the immersion fitting Pull the sensor cable through the O ring into the fitting and through the pigtail s...

Page 8: ...elivered The position ring 9 will only be received when PB30 00 is ordered This part is only needed when 11 2 pipe will be used in stead of 50 mm 5 3 2 Installation Mount the floating ball not exactly...

Page 9: ...ng sensor in fitting K1500FY 2 Holder 3 4 Nozzle parts K1500AZ 7 10m tubing 1 4 for jet cleaner K1530UL 3 4 6 Spray nozzle for jet cleaner K1530UK 6 3 Model PB30 Floating Ball Fitting Item Description...

Page 10: ...IM 12J06K04 E E 10 10 Dimensions 40 1 57 L 18 0 70 100 3 94 50 1 97 70 2 80 90 3 54 18 0 70 78 3 07 125 4 92 168 6 60 40 1 57 50 1 97 L 90 3 54 70 2 80 Figure 5 FD30 Figure 6 FD30 with flange...

Page 11: ...11 11 50 1 97 344 13 54 230 9 06 2570 50 100 2 pipe rail mounting DN 50 2 00 2 inch Stanchion Vertical Guide pipe 48 6 x 600 1 9 x 24 Min 110 4 35 Max 515 20 Fill piece Figure 7 Option MS1 Figure 8 PB...

Page 12: ...1 770 253 7000 Fax 1 770 251 2088 E mail info yca com www yca com YOKOGAWA ELECTRIC ASIA Pte Ltd 5 Bedok South Road Singapore 469270 Singapore Tel 65 241 9933 Fax 65 241 2606 E mail webinfo yas com sg...