background image

TECHNICAL GUIDE

MODELS: GY8S-DH/LY8S-DH

GAS-FIRED
HIGH EFFICIENCY SINGLE STAGE 
DOWNFLOW/HORIZONTAL FURNACES
STANDARD & Low NOx 

NATURAL GAS
40 - 130 MBH INPUT

Due to continuous product improvement, specifica-
tions are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.

Additional information can be found at 
www.gamanet.org.

EFFICIENCY
RATING
CERTIFIED

ISO 9001

Certified Quality

Management System

279747-YTG-A-0407

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

 

DESCRIPTION

These high efficiency, downflow/horizontal compact units
employ induced combustion, reliable hot surface ignition and
high heat transfer tubular heat exchangers. 

These furnaces are designed for residential installation in a
closet, attic or garage and are ideal for commercial applica-
tions. All units are factory assembled, wired and tested to
assure safe dependable and economical installation and
operation.

These units are Category I listed and may be common vented
with another gas appliance as allowed by the National Fuel
Gas Code ANSI Z223.1 (latest edition).

WARRANTY

20-year limited warranty on the heat exchanger.

10-year heat exchanger warranty on commercial applica-
tions.

5-year limited parts warranty.

FEATURES

Downflow/Horizontal models may be easily applied with-
out any field conversion

Top vent connection allows installation in narrow loca-
tions

Electronic hot surface ignition with high reliability and 
dependability

100% shut off main gas valve for added safety

High quality inducer motor for quiet operation

Standard terminals for controlling humidifiers & EAC's

40 VA control transformer, fuse protected

Easy to connect power and control wiring

Efficiency ratings of 80 AFUE attained by using tubular
heat exchangers

Cooling relay standard for easy installation of add-on
cooling

Blower off-delay for cooling SEER improvement

Multi-speed PSC, direct-drive blower motors to match
cooling requirements

Adjustable fan-off settings to eliminate "cold-blow"

Compact 40-in height allows installation in small space
confines

Low NOx models have been designed to meet specific 
code requirements.

All models are propane convertible.

Summary of Contents for GY8S-DH

Page 1: ...and may be common vented with another gas appliance as allowed by the National Fuel Gas Code ANSI Z223 1 latest edition WARRANTY 20 year limited warranty on the heat exchanger 10 year heat exchanger w...

Page 2: ...net Dimension A B C D G L Y8S040A12DH11 1200 A 14 1 2 13 1 4 12 10 3 8 G L Y8S060A12DH11 1200 A 14 1 2 13 1 4 12 10 3 8 G L Y8S080A12DH11 1200 A 14 1 2 13 1 4 12 10 3 8 G L Y8S080B16DH11 1600 B 17 1 2...

Page 3: ...1 2 12 0 80 0 40 70 G L Y8S100C16DH11 100 80 1600 21 12 0 80 0 25 55 G L Y8S100C20DH11 100 80 2000 21 14 0 80 0 25 55 G L Y8S115C16DH11 115 92 1600 21 12 0 80 0 35 65 G L Y8S115C20DH11 115 92 2000 21...

Page 4: ...1491 1412 1311 1192 1049 908 750 Low 1561 1493 1430 1373 1304 1199 1089 967 816 699 G L Y8S100B12DH11 High 1710 1650 1580 1510 1420 1330 1260 1160 1090 930 Medium High 1480 1440 1380 1330 1270 1180 10...

Page 5: ...em Static Pressure ESP without the filter 4 Select a filter pressure drop from the table based upon the number of return air openings or return air opening size and add to the ESP from Step 3 to deter...

Page 6: ...ion of compatible thermosets are available to provide optimum performance and features for any installation 1H 1C manual change over electronic non programmable thermostat 1H 1C auto manual changeover...

Page 7: ...eat W First Stage Heat W Single Stage Heat HM1 Humidistat Thermostat Installer Setup Number 1 System Type must be set to 0 Selection of GAS ELEC switch on thermostat not necessary Thermostat Installer...

Page 8: ...change without notice Printed in U S A 279747 YTG A 0407 Copyright by York International Corp 2007 All rights reserved Supersedes 246794 YTG C 0706 Unitary 5005 Norman Products York OK Group Drive 73...