background image

TECHNICAL GUIDE

STELLAR PLUS ECO

 2 TM

SPLIT-SYSTEM AIR CONDITIONERS

R-410A 12 SEER

MODELS:

H4AH024 THRU 060
(2 THRU 5 NOMINAL TONS)

Due to continuous product improvement, specifications 
are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.

Additional rating information can be found at 
www.ari.org.

R

N

E

M

P

I

U

Q

E

T

Y

R

AT

I

N

U

0

1

2

A R

I

R

A

D

N

A

T

S

D

I

S

N

O

T

C

E

S

F

O

C

C

I

F

I

T

R

E

N

O

I

T

A

HT

I

W

C

G N

I

YL

P

M

O

S

A

I

R

A

O

T

D

E

I

F

I

T

R

E

C

R

E

R

UT

C

A

F

U

N

A

M

C

-

G

NI

N O

I

TI

D

N

O

R

I

A

CERTIFICATION APPLIES ONLY

WHEN THE COMPLETE

SYSTEM IS LISTED

WITH ARI.

LISTED

036-21215-003 Rev. B (1202)

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

  

   

DESCRIPTION

The HAH Series condensing unit is the outdoor part of a ver-
satile system of air conditioning. It is designed to be custom-
matched with one of York’s complete line of evaporator sec-
tions, each designed to serve a specific function. Matching
Air Handlers are available for upflow, downflow or horizontal
application to provide a complete system. Electric heaters are
available if required. Add-On coils are available for use with
upflow, downflow or horizontal furnaces.

WARRANTY

5-year limited parts warranty.

10-year limited compressor warranty.

FEATURES

QUALITY CONDENSER COILS - 

The coil is constructed

of copper tube and hardened black coated aluminum fins

for durability and long lasting efficient operation. The fins
on the unit are protected with a decorative grille.

PROTECTED COMPRESSOR - 

The compressor is inter-

nally protected against high pressure and temperature.

This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which

protects the compressor if undesirable operating condi-

tions occur. Additionally the unit has high and low pressure
switch for extra protection against high pressure or loss of

charge. The compressor is protected by a 10 year limited

warranty.

DURABLE FINISH -

 Cabinet is made of powder painted

steel over prepainted primer. The pre-treated flat galva-

nized steel provides a better paint to steel bond, which

resists corrosion and rust creep. Special primer formulas
and champagne finish insure less fading when exposed to

sunlight. This finish has been tested to provide 1/3 greater

protection than conventional units.

LOWER INSTALLED COST - 

Installation time and costs

are reduced by easy power and control wiring connec-

tions. Hard start kits are available for non-scroll models. All

units contain enough refrigerant for a matching indoor coil
and 15 feet of interconnecting piping. The small base

dimension means less space is required on the ground or

roof.

TOP DISCHARGE - 

The warm air from the top mounted

fan is blown up away from the structure and any landscap-

ing. This allows compact location on multi-unit applica-

tions.

LOW OPERATING SOUND LEVEL - 

The upward air flow

carries the normal operating noise up away from the living

area. The rigid top panel effectively isolates any motor

sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and

compressor operating sounds.

LOW MAINTENANCE - 

Long life permanently lubricated

motor bearings need no annual servicing.

EASY SERVICE ACCESS - 

Fully exposed refrigerant con-

nections and a single panel covering the electrical controls

make servicing easy.

SECURED SERVICE VALVES -

Provided on both the liq-

uid and vapor sweat connections for ease of evacuating
and charging.

U.L. and C.U.L. 

listed - approved for outdoor application.

Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.

Summary of Contents for H4AH024S06

Page 1: ... which protects the compressor if undesirable operating condi tions occur Additionally the unit has high and low pressure switch for extra protection against high pressure or loss of charge The compressor is protected by a 10 year limited warranty DURABLE FINISH Cabinet is made of powder painted steel over prepainted primer The pre treated flat galva nized steel provides a better paint to steel bo...

Page 2: ...urrent Device Amps 2 20 25 35 45 45 60 Compressor Type 3 Inertia Inertia ScrollC ScrollC ScrollC ScrollC Compressor Amps Rated Load 9 9 12 6 15 4 18 6 20 5 27 5 Locked Rotor 48 66 7 83 105 109 158 Crankcase Heater Yes Yes No No No No Fan Motor Amps Rated Load 0 86 0 86 1 2 1 2 1 2 1 2 Fan Diameter Inches 18 18 24 24 24 24 Fan Motor Rated HP 1 8 1 8 1 4 1 4 1 4 1 4 Nominal RPM 1050 1050 850 850 850...

Page 3: ...7 65 55 4 61 2 G2FD035 S H 14 65 55 4 61 2 G2FD036 S H 17 21 75 55 2 61 7 65 0 G2FD042 S H 21 78 65 5 69 10 G2FD046 S H 17 78 65 5 69 10 75 8 G2FD048 S H 21 24 84 67 13 69 12 75 10 G2FD060 S H 24 90 71 15 77 13 84 0 G2FD061H24 90 77 18 84 9 G1HD024 59 55 0 G1HD036 69 55 7 61 7 65 10 G1HD048 84 67 13 69 9 75 0 G1HD060 96 77 6 84 0 F2RC F2FC024 61 F2RC F2FC030 65 55 2 F2RC F2FC036 73 61 2 F2RP F2FP0...

Page 4: ... H 24 1600 48 0 36 1 13 00 11 85 H4AH060S06 N1VSD20 10 15 18 30 24 G2FD060 S H 24 1600 58 5 44 5 12 55 10 90 H4AH060S06 N1VSD20 10 15 18 30 24 G2FD061H24 1600 59 0 45 7 12 65 11 10 1 PH 12 SEER AC F2RP RC FP FC FV4 5 H4AH024S06 F2RC FC030 5 8 10 15 18 850 23 2 16 7 11 70 10 60 H4AH024S06 F2RP FP024 5 8 10 18 850 24 0 18 0 12 00 10 80 H4AH024S06 F2RP FP030 5 8 10 15 18 850 24 6 18 6 12 00 10 75 H4A...

Page 5: ... 11 35 10 10 14 G1FA036S14 1060 29 0 21 5 11 50 10 40 17 21 G1FA036S17 21 1060 28 8 21 5 11 50 10 25 G1HD036 1060 30 4 22 9 12 00 10 70 14 G1UA030S14 1060 28 4 21 2 11 35 10 10 14 G1UA036S14 1060 29 0 21 5 11 50 10 40 17 21 G1UA036S17 21 1060 28 8 21 5 11 50 10 25 17 G2FD030 S H 17 1060 28 8 21 5 11 50 10 25 14 G2FD035 S H 14 1060 28 8 21 5 11 50 10 25 17 G2FD036 S H 17 1060 30 2 22 6 12 00 10 50 ...

Page 6: ...0 59 0 43 4 12 00 10 50 G1HD060 1800 57 5 41 8 11 80 10 25 21 24 G1UA060S21 24 1850 59 0 43 4 12 00 10 50 24 G2FD060 S H 24 1850 59 0 43 4 12 00 10 50 24 G2FD061H24 1850 59 5 45 0 12 10 10 65 COOLING CAPACITY Upflow Downflow Horizontal Furnaces and Coils Continued UNIT MODEL FURNACE COIL MODEL COOLING CFM RANGE MIN MAX W RATED CFM NET MBH SEER W O TDR SEER TDR EER TOTAL SENS COOLING CAPACITY With ...

Page 7: ... 41 0 30 6 12 60 11 55 P1XUD20V G1FA060S24 24 1360 42 0 31 7 12 85 11 85 P1XUD20V G1UA060S24 24 1360 42 0 31 7 12 85 11 85 P1XUD20V G2FD048 S H 24 24 1360 42 0 31 3 12 75 11 80 H4AH048S06 P1DUB16V G1FA048S17 17 1500 47 0 32 3 13 00 11 90 P1DUB16V G1UA048S17 17 1500 47 0 32 3 13 00 11 90 P1DUC20V G1FA048S21 21 1610 47 0 35 5 12 40 11 40 P1DUC20V G1UA048S21 21 1610 47 0 35 5 12 40 11 40 P1DUC20V G2F...

Page 8: ...ent accessory information refer to the price book or consult factory SOUND RATINGS Rated in accordance with ARI Standard 270 TYPICAL INSTALLATION TYPICAL FIELD WIRING 1 Phase Application UNIT MODEL SOUND RATINGS DECIBELS WITH SOUND BLANKET WITHOUT SOUND BLANKET 024 72 76 030 74 79 036 76 76 042 76 75 048 77 78 060 80 81 THERMOSTAT TO INDOOR BLOWER TO COIL NEC CLASS 2 WIRING NEC CLASS 1 WIRING TO P...

Page 9: ...7 3 18 1 17 3 16 0 K W 2 38 2 33 2 27 2 22 2 41 2 36 2 30 2 25 2 43 2 38 2 32 2 27 115 T C 21 8 18 6 15 4 13 9 21 9 18 9 15 7 14 3 22 0 19 1 16 0 14 7 S C 15 9 15 8 15 0 13 4 16 4 16 4 15 3 13 8 16 9 16 9 15 6 14 1 K W 2 53 2 45 2 40 2 35 2 56 2 48 2 43 2 38 2 58 2 51 2 46 2 40 125 T C 19 7 16 2 12 8 12 1 19 8 16 3 13 1 12 5 19 8 16 7 13 5 13 0 S C 15 4 15 0 13 8 11 8 16 0 15 5 14 0 12 0 16 5 16 1...

Page 10: ... 2 96 2 87 3 21 3 13 3 02 2 94 115 T C 28 0 24 6 20 1 17 6 27 6 24 8 20 6 18 2 28 8 25 4 21 1 18 8 S C 19 8 19 5 18 5 17 2 21 4 20 2 19 6 17 9 21 8 21 9 20 7 18 5 K W 3 29 3 19 3 07 2 98 3 30 3 22 3 11 3 03 3 38 3 28 3 17 3 10 125 T C 25 9 21 8 17 0 15 1 24 6 21 8 17 4 15 7 26 5 22 5 17 8 16 3 S C 17 7 18 0 16 7 15 5 19 9 18 6 17 9 15 9 19 7 21 2 19 1 16 3 K W 3 48 3 35 3 22 3 13 3 46 3 37 3 26 3 ...

Page 11: ...99 125 T C 31 7 27 7 19 7 32 5 27 9 20 7 33 2 29 4 21 7 S C 27 5 25 1 20 4 27 1 25 0 21 9 26 7 25 6 23 3 K W 4 51 4 44 4 31 4 58 4 52 4 35 4 56 4 49 4 36 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH 1000 CFM Air Handler Coil T C S C KW N1AHB1206 G2FD036 S H 17 1 00 1 00 1 00 N1AHB1206 G2FD046 S H 17 0 99 0 99 0 98 N1AHD1406 G2FD048 S H 24 1 02 1 03 0 99 N1VSB12 G2...

Page 12: ...3 4 07 3 98 3 94 4 26 4 19 4 11 4 07 115 T C 37 8 35 3 30 9 26 4 38 9 35 6 30 9 27 2 39 9 36 0 30 9 28 0 S C 29 0 25 5 26 6 25 2 31 0 27 2 28 4 26 9 33 0 29 0 30 3 28 5 K W 4 40 4 34 4 22 4 22 4 52 4 46 4 32 4 31 4 65 4 57 4 45 4 43 125 T C 35 0 32 9 28 3 23 7 36 4 33 2 28 0 24 6 37 7 33 4 27 7 25 5 S C 29 4 24 0 25 3 23 5 31 6 25 8 27 4 25 2 33 7 27 6 29 4 26 9 K W 4 79 4 72 4 57 4 61 4 91 4 85 4...

Page 13: ... 7 43 6 40 0 35 2 S C 32 6 31 5 30 9 34 1 33 1 32 5 35 6 34 7 34 0 K W 5 23 5 15 5 02 5 29 5 23 5 10 5 35 5 32 5 19 125 T C 37 2 34 1 30 3 37 9 34 2 30 8 38 4 34 4 31 3 S C 31 2 30 3 29 6 32 4 31 8 31 3 33 7 33 4 32 9 K W 5 75 5 69 5 46 5 82 5 77 5 56 5 89 5 86 5 67 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH 1000 CFM Air Handler Coil T C S C KW N1AHC1606 G2FD048...

Page 14: ... 5 70 5 62 5 50 5 75 5 67 5 56 5 80 5 73 5 63 105 T C 59 7 55 6 49 8 60 3 56 2 50 5 60 9 56 7 51 1 S C 42 5 40 7 41 2 44 2 42 0 42 0 45 8 43 2 42 8 K W 6 36 6 25 6 09 6 41 6 31 6 16 6 46 6 37 6 24 115 T C 55 8 51 6 45 2 55 9 52 2 45 7 56 0 52 7 46 1 S C 41 4 39 2 38 7 42 9 40 9 40 0 44 4 42 6 41 3 K W 7 12 6 99 6 84 7 17 7 04 6 92 7 23 7 10 7 00 125 T C 51 9 47 6 40 6 51 5 48 2 40 9 51 1 48 7 41 1...

Page 15: ...TION UPFLOW HORIZONTAL AND DOWNFLOW Available with factory installed horizontal drain pan ADD ON COILS FOR FURNACE APPLICATIONS G1NA UNCASED UPFLOW G1FA FULL CASED UPFLOW AIR HANDLERS FOR NON FURNACE APPLICATIONS N1AH OR N1VS MODULAR BLOWER UPFLOW HORIZONTAL AND DOWNFLOW F2RC F2FC OR F2RC F2FP FAN COIL UNITS UPFLOW HORIZONTAL G2FD COIL ...

Page 16: ...e without notice Printed in U S A 036 21215 003 Rev B 1202 Copyright by York International Corp 2002 All rights reserved Supersedes 036 21215 003 Rev A 0602 Unitary 5005 Norman Products York OK Group Drive 73069 NOTES ...