035-19650-001 Rev. C (0404)

USER’S INFORMATION,

MAINTENANCE AND 

SERVICE MANUAL

HIGH EFFICIENCY

TUBULAR HEAT EXCHANGER SERIES

MODELS: P*XU/ G9D-UP

Two Stage (Upflow)

EFFICIENCY
RATING
CERTIFIED

This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.

The manufacturer recommends that the user read all sec-
tions of this manual and keep the manual for future refer-
ence.

 

SECTION I: USER’S INFORMATION

SAFETY

1.

The furnace area must be kept clear and free of combustible mate-
rials, gasoline and other flammable vapors and liquids.

2.

Insulating materials may be combustible. The furnace must be
kept free and clear of insulating materials. The furnace area must
be examined when installed in an attic or other insulated space or
when insulation is added to be sure that the insulation material has
been kept away from the furnace.

3.

The furnace needs air for combustion in order to operate properly
and safely. Do not block or obstruct air openings on the furnace,
air openings to the area where the furnace is installed, or spaces
around the furnace.

4.

Follow the instructions exactly as shown on the OPERATING
INSTRUCTION LABEL or the Start-up and Shutdown Instructions
on Page 3 of this manual when lighting the furnace or turning the
furnace off.

5.

Should the gas supply fail to shut off or if overheating occurs, shut
off the gas valve to the furnace before shutting off the electrical
supply.

6.

Do not use this furnace if any part has been under water. A flood-
damaged furnace is extremely dangerous. Attempts to use the fur-
nace can result in fire or explosion. A qualified service agency
should be contacted to inspect the furnace and replace all gas
controls, control system parts, electrical parts that have been wet
or the furnace if deemed necessary.

FIRE OR EXPLOSION HAZARD - 

Failure to follow safety

warnings exactly could result in serious injury, death, or prop-
erty damage.

— 

Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other
appliance.

—  

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone 
(including cell phone) in your building.

Leave the building immediately.

Immediately call your gas supplier from a neighbor’s 
phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire depart-
ment.

— 

 Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier.

TABLE OF CONTENTS

CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

USER’S INFORMATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

SAFETY   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
INSTRUCTIONS FOR EXAMINING THE FURNACE 
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
HOW YOUR GAS FURNACE WORKS   . . . . . . . . . . . . . . . . . . . . . . 3
START-UP AND SHUTDOWN INSTRUCTIONS  . . . . . . . . . . . . . . . 3
FURNACE USER MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . 3

SERVICE AND MAINTENANCE MANUAL . . . . . . . . . . . . . . . . . . . . . 5

SAFETY SECTION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
FURNACE MAINTENANCE SECTION . . . . . . . . . . . . . . . . . . . . . . . 5
SEQUENCE OF OPERATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

DIRECT DRIVE BLOWER MOTOR   . . . . . . . . . . . . . . . . . . . . . . . . .6
INSTALLATION OF PSC MOTOR:  . . . . . . . . . . . . . . . . . . . . . . . . . .6
FURNACE CLEANING SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . .7
TROUBLESHOOTING   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
FURNACE DIAGNOSTICS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

REPLACEMENT PARTS LIST   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

FIELD INSTALLED ACCESSORIES - NON-ELECTRICAL   . . . . . .12

REPLACEMENT PART CONTACT INFORMATION . . . . . . . . . . . . .12
WIRING DIAGRAM   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

LIMITED WARRANTY   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

CONTACT INFORMATION

Go to website at www.york.com click on “contact”, then click on “contact form” and follow the instructions.

Contact us by mail:

York International

Consumer Relations

5005 York Drive

Norman, OK 73069

  CLICK ANYWHERE on THIS PAGE to RETURN to YORK HVAC AGE & MANUALS & ERROR CODES at InspectApedia.com

Summary of Contents for P XU Series

Page 1: ...r explosion A qualified service agency should be contacted to inspect the furnace and replace all gas controls control system parts electrical parts that have been wet or the furnace if deemed necessa...

Page 2: ...making sure the physical support is sound without sagging cracks or gaps Examine the furnace base making sure it is physically sound without cracks gaps or sagging and has a good seal 5 Examine the fu...

Page 3: ...Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow B in the safety information above If you don t smell gas go to next step 7 Move gas control switch to the ON position Do not...

Page 4: ...ilter size from Table 1 Removing Filters Internally Mounted Air Filters Most upflow furnaces have their filters located on the side or bottom of the furnace in a filter wire retainer located inside th...

Page 5: ...iliary Limit and Roll out Switches for closed contacts The Control checks that the Low Fire Pressure Switch 1LP is open The Inducer Motor is energized on high speed closing the con tacts of 1LP The Co...

Page 6: ...the furnace model being serviced Follow the procedure below to replace the motor Removal of the Variable Speed Blower Motor Assembly The procedure for removing the variable speed blower assembly 1 Dis...

Page 7: ...l power and gas supply to the furnace 13 Check furnace operation Cleaning the Secondary Heat Exchanger 1 Follow steps 1 8 under cleaning the Heat Exchanger 2 Remove the vent piping from the vent blowe...

Page 8: ...Dirty Filter Improperly sized duct system Incorrect blower speed selection Incorrect firing rate Faulty blower motor Faulty Control 6 Flash Reason 1LP has opened five times during one call for heat Ef...

Page 9: ...W INDUCER LOW STAGE PRESSURE SWITCH HSI 1ST STAGE MAIN VALVE FLAME SENSE LOW CIRCULATOR HEAT SPEED 1ST STAGE LOW PRESSURE SWITCH CLOSE RECOGNITION HSI WARM UP 17 SEC IGNITION ACTIVATION PERIOD 4 SEC T...

Page 10: ...E CIR HUM EAC XFMR LINE PARK PARK HEAT COOL 1 4 2 6 10 12 14 7 8 9 13 3 5 15 17 16 11 C G R W Y HUM EAC XFMR LINE CIR HUM EAC XFMR LINE PARK PARK HEAT COOL 19 24 25 31 26 32 33 34 50 21 22 23 27 45 28...

Page 11: ...CHANNEL TOE PLATE 32 COVER HEAT EXCHANGER 33 PANEL FRONT Blower 34 PANEL FRONT Burner PANEL FRONT Burner 35 PANEL TOP 36 SUPPORT BURNER 37 WRAPPER CABINET Insulated WRAPPER CABINET Insulated 38 PANEL...

Page 12: ...NAL BOTTOM FILTER RACK 17 1 2 CABINETS 21 CABINETS 24 1 2 CABINETS CONDENSATE NEUTRALIZER KIT ALL MODELS REPLACEMENT PART CONTACT INFORMATION This is a generic parts list To request a complete parts l...

Page 13: ...035 19650 001 Rev C 0404 Unitary Products Group 13 SECTION IV WIRING DIAGRAM FIGURE 9 Wiring Diagram...

Page 14: ...035 19650 001 Rev C 0404 14 Unitary Products Group NOTES...

Page 15: ...035 19650 001 Rev C 0404 Unitary Products Group 15...

Page 16: ...plies only to products installed in the United States and Canada EXCLUSIONS This warranty does not cover any 1 Shipping labor or material charges 2 Damages resulting from transportation installation o...

Reviews: