Precautions In Use
Parts Identification and Functions
How to Recharge
Must-Read Before Use
How to Use
How to Maintain
How to Store
Troubleshooting
Product Specification

2
3
4
4
5
7
9

10
11

User’s Manual / Warranty

YWH-070

Portable H2 Server

W

henever, 

W

herever

with

H2 Water

Summary of Contents for Portable H2 Server

Page 1: ...ation and Functions How to Recharge Must Read Before Use How to Use How to Maintain How to Store Troubleshooting Product Specification 2 3 4 4 5 7 9 10 11 User s Manual Warranty YWH 070 Portable H2 Server Whenever Wherever with H2 Water ...

Page 2: ...e the device without water stored inside of the body Place the device in a moisture free well ventilated place Avoid using the device in temperatures well below freezing It may cause trouble if the water remains inside of the body Connect the water bottle with Bottle Stopper tightly to prevent water leaking Before test please tightly close this Bottle Stopper Otherwise it may happen to leak becaus...

Page 3: ... all accessories in the package Parts Identification and Functions Front View Top Cover to protect the body while not used Bottle Stopper Silicon Gasket Silicon Gasket DC Adaptor Tip Power Button Plug End Rear View Body DC Adaptor ...

Page 4: ...er which is inside the body for electrolysis wet condition Fill the Electrolysis Chamber with warm water approximately 50 60 to operate the device then put citric acid or vinegar inside the hydrogen generator Press the Power Button to operate the device After used wash out the device several times and use again with bottle Insert the plug of DC Adaptor into the AC socket Charging begins while rech...

Page 5: ...urface to make it straightly stand Remove the Cap of 500ml water to connect How to Use Top Cover Notice Do not use a plastic bottle which size is bigger than 500ml and all of glass bottle The body cannot stand Use only mineral water Avoid using water in a high degree of hardness and flavored water This device is designed to be used with general size of bottle but do not use it if the size of conne...

Page 6: ...igh concentrated hydrogen If the bottle stopper flashes amber the battery is low Recharge the battery During charging the amber light is ON When charging is completed the blue light is ON Be careful to avoid tipping down the device during operation Be especially careful when there are young children such as infants Do not use more than three consecutive times It may cause trouble because of hydrog...

Page 7: ... use of the device may result in building up scale on electrodes It is recommanded to clean up after one day of use to maintain performance You can use a soft wet towel or sponge to clean the body General Maintenance after use How to Clean Up After Using One Day How to Maintain Inside of the body Outside of the body Open the top cover and place 15 ml of the citric acid or vinegar mixed water in th...

Page 8: ...of vinegar or some amount of citric acid Warm water 50 60 Few drops of vinegar or Some amount of Citric acid Wash the Electrolyzer with warm water Warm water City water Electrolysis chamber should always be in wet condition Switch ON and wait for 5 min Wash out Wash out Connect the device with Sweet Water Bottled Mineral Water Switch ON 5 min 900 1150ppb ...

Page 9: ...p Cover Drain out liquid inside of the body Fill the Electrolysis Chamber with hot water approximately 80 85 and put 1 2 drops of citric acid in it After about 10 minutes press the power button to generate the device After operation is done drain out the water inside and wash the device with clean water several times No need to connect the bottle When used after long time General method for storin...

Page 10: ...fuses Please contact Service Center if you dispose the device Recharging is required The bottle stopper blinks amber if the battery is low Getting proper fixing Get proper bottle neck thread Silicone Gasket is missing or twisted on the bottle stopper the gasket must be properly fixed Recharging is required The Electrolysis Chamber cleaning is required Water leakage Hydrogen level is lower than nor...

Page 11: ...Hydrogen Water SERVER YWH 070 INPUT AC100 240V 50 60Hz 0 3A OUTPUT DC5V 2A 5W 196g Ø69mm Height 103mm Electrolysis 5min Approx 900ppb 10min 5min x 2 Approx 1100ppb 5min in operation Approx 90 120min 2 3 years depends on customer using less or Lithium ion battery 3 7V 1060mA 1cell MADE IN KOREA Product specifications may change without prior notice due to quality improvement and design changes Prod...