INSTALLATION INSTRUCTIONS
Model 570PHM;570PHB;570PHXL
Fig.1
Fig. 2
FIXTURE
WIRES
Black or
Smooth
HOUSE
WIRES
Black
(Hot)
FIXTURE
WIRES
White or
Ribbed
HOUSE
WIRES
White
(Neutral)
FIXTURE
WIRES
Bare
Copper
(Ground)
HOUSE
WIRES
Green
or
Bare
Copper
(Ground
)
FOR YOUR SAFETY WARNING: BE SURE THE ELECTRICITY TO THE WIRES YOU ARE WORKING
ON IS SHUT OFF; EITHER THE FUSE IS REMOVED OR THE CIRCUIT BREAKER IS SHUT OFF.
GENERAL You don’t need special tools to install this fixture. Be sure to follow the steps in the order given.
Under no circumstances should a fixture be hung on house electrical wires, nor should a swag type fixture be
installed on a ceiling which contains a radiant type heating system. Read instructions carefully. If you are unclear
as to how to proceed, consult a qualified electrician.
NOTE: Proper wiring is essential for the safe operation of this fixture.
HANGING THE FIXTURE (Fig. 1)
1. Shut off the power at the circuit breaker and remove
the old fixture including the mounting hardware.
2. Carefully unpack your new fixture and lay out all the
parts on a clear area. Take care not to lose any small
parts necessary for installation.
CONNECTING THE WIRES (Fig.2)
3. While supporting the fixture, connect the electrical
wires as shown in figure 2. If your post has a ground
wire (green or bare copper), connect the fixture
ground wire to it. If not, consult your electrician for
proper grounding. After the wires are connected, tuck
them carefully inside the post (A).
4. Place the fixture onto pole, and secure with the 3
mounting screws (B)
COMPLETING THE INSTALLATION (Fig. 1)
5.
Take off the roof (D) by loosening two screws (C),
install the bulb (T Bulb Medium base, not included.) in
accordance with the fixture’s specification. Attach the
roof (D) back to the cage (F) by two screws (C).
DO NOT EXCEED THE MAXIMUM WATTAGE RATING!
Your installation is now complete. Return power to
the junction box and test the fixture