ASP - 10 STAIRCASE TIMER
INSTRUCTION MANUAL
Zakład Mechaniki i Elektroniki
ZAMEL sp.j.
J.W. Dzida, K. Łodzińska
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamelcet.com, e-mail: marketing@zamel.pl
APPERANCE
FEATURES
DESCRIPTION
ی Staircase lighting control,
ی Continuous ON-time (t) adjustment of
10 seconds to 16 minutes,
ی Soft switch ON (0.8 s),
ی Slow switch OFF (15 s),
ی Counter-interlock and retriggering,
ی Device triggering by means of the L
wire,
ی Applicable together with single pole
push buttons, illuminated,
ی Two-conductor control system,
ی Easy applicable together with any
existing electrical system,
ی Supplied in series with load.
The ASP-10 staircase timer is de
-
signed for corridor and staircase lighting
control. After the circuit triggering the timer
keeps the light ON for the preset time and
then switches it OFF. It has an adjustable
ON-time (t) setting of 10 seconds to 16 mi
-
nutes. On-time may be adjusted by means
of a potentiometer. The ASP-10 staircase
timer may by applied as a time relay for de
-
layed switch-OFF. It is possible to mount
the device under a push button, in a deep
junction box of 60 mm diameter.
TECHNICAL DATA
ASP - 10
Power leads: L(black), brown - in series with the load
Rated voltage: 230 V~
Rated voltage tolerance: -15 ÷ +10 %
Rated frequency: 50 Hz
Rated current:
10 mA
Trigger conductor: IN (red)
Load supply:
brown
ON-time (t) adjustment range: 10 s ÷ 16 min
ON-time setting accuracy: ±3 %
ON-time setting repeatability: ±5 %
ON-time setting: continuous (potentiometer)
Load supply indicator: red LED
Permissible load: 30 ÷ 300 W
Fuse technical specification: 5 x 20 mm, ultra-fast, 2 A / 250 V
Control: triac
Connection wires quantity: 3
Connection wire section:
1 mm
2
Connection wire length: 10 cm
Operating temperature: -20 ÷ +45
o
C
Operating position: optional
Casing fastening: for 60 mm junction box
Casing IP: IP40
Protection class:
II
Overvoltage category:
II
Pollution level: 2
Dimensions: 50 x 50 x 15 mm
Weight: 25 g
Standard conformity: PN-EN 60669-1; PN-EN 60669-2-1
PN-EN 61000-4-2,3,4,5,6,11
Load ON indicator
ON-time setting
Load supply lead
Power lead (L)
Fuse socket
Trigger lead (IN)
b
ro
w
n
r
ed
b
l
a
c
k
The device should be
connected to a single-
phase system accordin
-
gly to current standards.
The device connection
swill be described in this
manual. Only qualified
electricians are allowed to connect,
assembly and adjust the timer. It is ne
-
cessary to read this manual before the
timer mounting. Do not disassembly the
timer casing or you will lose any war
-
ranty rights and expose yourself to the
electric shock hazard. Before mounting
operation make sure of disconnecting
the connection wires from the electric
network. Use a cross-head screwdriver
of 3.5 mm diameter to mount the devi
-
ce. The timer should be carried, stored
and used in an appropriate way. Do not
mount the timer in case of any device
parts lack, damage or deformation. In
case of malfunction please notify the
manufacturer.
CAUTION