background image

ZCM-11, ZCM-11/U TIME PROGRAMMER

WEEK’S - SINGLE-CHANEL

 

INSTRUCTION MANUAL

Zak

ł

ad Mechaniki i Elektroniki 

ZAMEL 

sp.j.

J.W. Dzida, K. 

Ł

odzi

ń

ska

ul. Zielona 27, 43-200 Pszczyna, Poland

Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04

www.zamelcet.com

, e-mail: marketing@zamel.pl

APPEARANCE

FEATURES

TECHNICAL DATA

DESCRIPTION

ZCM-11

Power supply terminals: A1, A2

Input rated voltage:

ZCM-12: 230 V AC

~

(-15 ÷ +10 %) 

ZCM-12/U: 24 ÷ 250 V AC, 30 ÷ 300 V DC

Nominal frequency:  50 / 60 Hz

Rated power consumption: 2 W / 14 VA

 Number of channels: 1

Program quantity: 400 (200 On/Off pairs)

Program: daily, week’s

Operating modes: manual, automatic, random, impulse

Change of season summer/ winter: automatic, manual

Colour of LCD panel lighting: amber

Input: yes

Accuracy of time measurement: max ±1 s / 24 h  at temp. 25 °C

Time of clock maintenance: 3 years

Time of programme maintenance: 10 years

Clamps of release system: IN, IN, IN, IN

Receiver input (supply) terminals: 11, 12, 14

Output relay parameters: 1 NO/NC-16 A/250 V AC1 4000 VA

Number of terminal clamps:  12

Section of connecting cables:  0,2 ÷ 2,50 mm

2

Ambient temperature range: -20 ÷ +60 

o

C

Operating position: freely

Mounting: rail TH 35 (PN-EN 60715)

Protection degree: IP20 (PN-EN 60529)

Protection level:  II

Overvoltage category: II

Pollution degree: 2

Dimensions: double-modular (35 mm) 90x35x66 mm

Weight: 0,140 kg

Reference standards: PN-EN 60730-1; PN-EN 60730-2-7

PN-EN 61000-4-2,3,4,5,6,11

 Week’s cycle control in dependence of 

the current hour,

 Double-module casing with a protection 

flap,

 Random op mode, additional control 

input IN,

 Many programmes enabling various 

applications,

 LCD display illumination,

 Mounted on TH 35 rail.

Programmable control timers are de-

signed for time functions execution in 
automatics and control systems. Week’s 
programmer controls the output relay in de-
pendence of program settings (day, hour). 
The device is 

fi

 tted with some additional 

functions, among other things the random 
function that is used for the operating mode 
changing by means of an external push 
button. It is possible to mount the device 
on TH 35 rail and seal it if needed. A simple 
menu layout and an ergonomic keyboard 
enable easy and intuitive unit operating.

The construction of the system guar-
antees supporting of all the settings 
with battery energy when the electric 
power supply is off.

CAUTION: 
Before installing 
the device in the 
switchboard 
or starting the 
system operation 
in order to pro-
gramme it, the 
battery security 
separator should 
be removed against 
discharging.

The  device  should  be  connected 

to a singlephase system accor-

ding  to  current  standards.  The 

device connections will be descri-

bed in this manual. Only quali

fi

 ed 

electricians are allowed to mount, 

connect and adjust the device. It is necessary 

to read this manual and know the unit functions 

before the device mounting. Do not disassembly 

the device casing or you will lose any warranty 

rights and expose yourself to the electric shock 

hazard. Before mounting operation make sure 

of disconnecting the connection wires from the 

electric network. Use a cross-head screwdriver 

of 3.5 mm diameter to mount the device. The 

relay should be carried, stored and used in an 

appropriate way. Do not mount the device in 

case of any device parts lack, damage or defor-

mation. In case of malfunction please notify the 

manufacturer.

CAUTION

VER. 002_21.09.2009

Winter/summer time

Random mode

Manual mode

Automatic mode

Week’s day

Relay state

Info 

fi

 eld

Current time (hh:mm:ss)

Power terminals
(A1, A2)

LCD display

Control buttons

Relay output terminals
(12, 12, 11, 11, 14, 14)

Trigger terminals

(IN, IN, IN, IN)

The symbol means selective collecting 
of electrical and electronical equipment. 
It is forbidden to put the used equipment 
together with other waste.

DESCRIPTION

MAIN MENU

DATE SETTING

 

 - Current date setting; entry after pressing OK;

 YEAR - choose adequate year with cursors 

 con

fi

 rm with OK, range of 

years: 2000÷2099;

 MONTH - choose month with cursors 

 con

fi

 rm with OK;

 DAY - choose day with cursors 

 con

fi

 rm with OK; the system has a protec-

tion against introducing incorrect parameter of a day for a given month (it 

takes into account leap years and it automatically calculates the day of the 

week on the basis of an arranged date);

 Con

fi

 rmation causes movement to a date setting window and set-up of cur-

rent summer/ winter time - if the option 

 is arranged.

It is possible to exit every submenu window in any moment without sav-

ing settings by pressing the button   or  .

Description of elements and messages displayed

 

- days of week  

 

- day, 

- year

 - transmitter’s status 

 

 - program setting

 - automatic mode   

 

 - current time setting and summer/winter time shift

 - manual mode 

 

 

 - current date setting

 - random mode 

 

 

 - random mode setting

 - impulse mode 

 

 

 -  extenal input setting

 - external input 

 

 

 - impulse mode setting

  - winter time 

 

 

 - automatic, 

 - user

 - summer time 

 

 

 

 

 

 

 - on/off

Button description

   

• in the main window - the automatic mode enter or relay state changeover, if the timer already in the automatic 

mode;

   

• in the main window (3 seconds) - the random mode enter / exit;

   

• in the random mode - randomizing active/inactive manual toggle;

   

• the other windows - exit to a higher level without changes saving; 

   

• in the main window - the manual mode enter or the relay state changeover, if the timer already in the manual mode;

   

• in the random mode - the relay state changeover and randomizing switch-OFF;

   

• the other windows - exit to a higher level without changes saving;

 

  • in the main window - the main menu enter;

   

• the other windows - a submenu enter or setting acknowledgement;

 

  • window/option toggle or set value increase/decrease;

 

Menu enter by pressing OK;

menu items scrolling by means of cursors 

.

 Function Description

 

 

PROGRAM SETTING

 

 CURRENT 

TIME 

SETTING

 

 

CURRENT DATE SETTING

 

 WINTER/SUMMER 

TIME 

SETTING

 

 

RANDOM MODE SETTING

 

 

EXTERNAL INPUT SETTING

 

 

IMPULSE MODE SETTING

TIME SETTING

WINTER / SUMMER TIME SETTING

OPERATING MODE CHANGE (AUTOMATIC, MANUAL, RANDOM)

 

 - setting the current clock time; entry after pressing 

OK;

 HOUR- choose adequate hour with cursor 

 which you can 

set in 1-24   or 1-12   (AM) and 1-12   (PM)format; con

fi

 rm 

with OK;

 MINUTES - choose adequate parameter of minutes with cur-

sors 

 con

fi

 rm with OK;

 Con

fi

 rmation of the parameter of minutes causes simultane-

ous nulli

fi

 cation of the parameter of seconds and movement to 

the window of time setting.

It is possible to exit every submenu window in any moment 

without saving settings by pressing the button   or  .

 

 - winter/summer time toggle mode selection: 

 - 

automatic time changing on the last March Sunday, at 2:00 

into summer time and on the last October Sunday, at 3:00 into 

winter time, 

 - winter/summer timer toggle manual, by 

user; option entering after pressing OK;

   MODE SETTING - with 

 select 

 or 

 acknowl-

edge with OK; after selecting 

, winter/summer time will 

be toggled automatically; after selecting 

 mode you will 

enter the next window;

 With 

 select winter/summer, where   is winter time,   - 

summer time; if the time icon is changed, the timer will correct 

the current time appropriately; acknowledge by pressing OK;

 After time mode selecting winter/summer time change window 

will be open. 

 MANUAL OP MODE TOGGLE - if the main window is open 

and the timer is in the automatic mode   pressing key   will 

force the unit to toggle into the manual mode and the relay 

state changeover;

   Successive   key pressing will force the relay state changeo-

ver without the op mode;

 AUTOMATIC MODE TOGGLE - if the main window is open 

and the timer is in the manual mode   pressing key   will force 

the unit to toggle into the automatic mode and the relay state 

changeover;

   Successive   key pressing will force the relay state change-

over without the op mode;

 RANDOM MODE TOGGLE - in order to enter the random 

mode it is necessary to press and hold   key for 

3 secs

;

 Continuous light   iindicates that the timer is not in the time 

range where ON/OFF states randomizing is to be active, and 

the pulsing light indicates that the unit is randomizing ON/

OFF states according to RANDOM MODE SETTING menu 

settings; pressing key   orces randomizing ON/OFF states 

and the relay state changeover (  pulsing  ), and RANDOM 

MODE SETTING menu settings are still binding; successive 

pressing   key forces randomizing to be OFF;

   Pressing   key forces the relay changeover and randomiz-

ing switch-OFF, if it was active (  is lighting). The random 

mode exit is possible by pressing and holding   for 

3 secs.

  . 

Randomizing activity/inactivity update is being operated either 

in automatic or manual mode.

Reviews: