background image

RADIO GATE CONTROLLER ROB-01/12-24V

 

MANUAL INSTRUCTION

APPEARANCE

The device is designed for 

single-phase installation and 

must be installed in accord-

ance with standards valid in a 

particular country. The device 

should be connected accord-

ing to the details included in 

this operating manual. Installation, connection 

and control should be carried out by a qualified 

electrician staff, who act in accordance with the 

service manual and the device functions. 

In case of casing dismantling an electric shock 

may occur, and the guarantee is lost then.  

Before installation make sure the connection 

cables are not under voltage. The cruciform 

head screwdriver 3,5 mm should be used to 

instal the device. Improper transport, storage, 

and use of the device influence its wrong func-

tioning. It is not advisable to instal the device in 

the following cases: if any device part is missing 

or the device is damaged or deformed. In case 

of improper functioning of the device contact 

the producer.

CAutioN!

FEAtuRES

tECHNiCAL DAtA

DESCRiPtioN

●  cooperation with wireless EXTA FREE 

system transmitters,

●  operation control of entry gates, garage 

gates, and other electric drives,

●  universal  low-voltage  power  supply 

(12-24V 

~/

),

●  1 remote control can be used for differ-

ent drives (entry gate, garage) where 

ROB-01/12-24V device is mounted,

●  connection possibility of external wired 

antenna,

●  wide range of operation (up to 250 m),

●  possibility of increasing operation range 

by means of RTN-01 retransmitter.

Radio gate controller ROB-01/12-

24V is a universal (any gate manufactur-

er) operation controller of garage gates 

and similar electric drives that enables 

to control their operation by means of 

EXTA FREE transmitters. It is possible to 

control few things using one remote con-

trol - entry gate, garage gate, room light-

ing, etc. The device can be connected to  

a suitable wire terminal used as an ex-

ternal antenna.

ROB-01/12-24V

Input (supply) terminals: A1, A2

Input rated voltage: 12 ÷ 24 V ~/

Nominal power consumption: 0,2 W

Number of operation modes: 1

Number of channels: 1

Transmission: radio 868,32 MHz

Coding way: unidirectional

Coding: addressing transmission

Maximum number of transmitters: 32

Range: up to 250 m in the open area

Optic signalling of device operation: LED red diode

Additional antenna terminals: ANT

Relay output terminals: 11, 14

Relay parameters: 1NO 2 A / 250 V~ AC3 500 VA (dry contact)

Number of terminal clamps: 5

Section of connecting cables: up to 2,5 mm

2

Ambient temperature range: -10 ÷ +55 

o

C

Operating position: free

Casing mounting: installation cable box Ø60 mm

Casing protection degree: IP20 (EN 60529)

Protection level: III

Overvoltage category: II

Pollution degree: 2

Surge voltage: 1 kV (EN 61000-4-5)

Dimensions: 47,5 x 47,5 x 20 mm

Weight: 0,04 kg

Reference standard: EN 60669, EN 60950, EN 6091000

The symbol means selective 

collecting of electrical and electronic 

equipment.  

It is forbidden to put the used 

equipment together with other waste.

The ZAMEL company devices 

which are characterised  

with this sign can cooperate 

with each other.

Optic signalling of receiver’s operation
Programming push-button

Relay output terminals (11, 14)

Input (supply) terminals (A1, A2)

Antenna terminals (ANT)

VER. 003_20.05.2011

ZAMEL 

Sp. z o.o.

ul. Zielona 27, 43-200 Pszczyna, Poland

tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04

www.zamelcet.com

, e-mail: marketing@zamel.pl

Reviews: