background image

COOPERATION AND OPERATING RANGE

* 1-channel transmitters do not cooperate with roller blind controllers

CAUTION: The given range concerns open area - an ideal condition without any 

natural or artificial obstacles. If there are some obstacles between a transmitter 

and a receiver, it is advisable to decrease the range according to: wood and plas-

ter: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %, 

metal: from 90 to 100%, glass: from 10 to 20 %, Over- and underground medium 

and high electrical power lines, radio and television transmitters, GSM transmit-

ters set close to a device system have also a negative influence on the range.

Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01
RNK-02

180 m

200 m

200 m

200 m

200 m

250 m

180 m

250 m

250 m

180 m

250 m

RNK-04

180 m

200 m

200 m

200 m

200 m

250 m

180 m

250 m

250 m

180 m

250 m

P-256/8

230 m

250 m

250 m

250 m

250 m

300 m

200 m

300 m

300 m

230 m

300 m

P-257/4 (2)

180 m

200 m

200 m

200 m

200 m

250 m

180 m

250 m

250 m

180 m

250 m

RNM-10

230 m

250 m

250 m

250 m

250 m

300 m

200 m

300 m

300 m

230 m

300 m

RNP-01

160 m

180 m

180 m

180 m

180 m

200 m

160 m

200 m

200 m

160 m

200 m

RNP-02 

160 m

180 m

180 m

180 m

180 m

200 m

160 m

200 m

200 m

160 m

200 m

RNL-01

160 m

180 m

180 m

none*

none*

200 m

160 m

200 m

200 m

160 m

200 m

RTN-01

200 m

200 m

200 m

200 m

200 m

250 m

200 m

250 m

250 m

200 m

250 m

RCR-01

160 m

180 m

180 m

none*

none*

200 m

160 m

200 m

200 m

160 m

200 m

RTI-01

160 m

180 m

180 m

180 m

180 m

200 m

160 m

200 m

200 m

160 m

200 m

RXM-01 

230 m

250 m

250 m

250 m

250 m

300 m

200 m

300 m

300 m

230 m

300 m

REMOTE CONTROLS DELETION

 Press PROG push-button of RDP-01 device for a longer time.   After 5 seconds LED 

red diode switches on (signal pulsates) and then it switches off.   Release the push-

button in RDP-01 - MEMORY IS DELETED.

TIME PROGRAMMING

 Press PROG push-button of RDP-01 device for a longer time till LED red diode switches 

on (constant signal). Next release PROG push-button. Wait (for about 5 seconds) till LED red 

diode switches on (first signal pulsates, next the signal is constant).   Press PROG push-

button of RDP-01 device and then release it. LED red diode switches off and then switches on 

(signal pulsates). Every LED diode pulse equals 1 second.   After the adjusted time is finished 

(the number of LED red diode flashes) press PROG push-button and then release it - TIME IS 

ADDED. Maximum time is 18 hours.

TIME mode

 (one push-button):

 Press PROG push-button of RDP-01 device for a longer time till LED red diode 

switches on (constant signal). Next release PROG push-button.   Press and then re-

lease transmitter’s push-button.LED red diode switches on (first signal pulsates, next 

the signal is constant).   Press and release the same transmitter’s push-button. LED 

red diode switches on (signal pulsates) and then switches off - THE TRANSMITTER 

IS ADDED.

CAUTION: Every transmitter can cooperate with RDP-01 in a different mode, de-

pending on how they were added to the device. One transmitter can be added 

during one programming cycle. Full memory is signalled with pulsating LED red 

diode.

WIRELESS CONTROL SET - LIGHTING WITH DIMMING FUNCTION

 

RZB-02

TECHNICAL DATA

RNK-02

RDP-01

Input (supply) terminals:

-

L, N

Input rated voltage:

3 V DC (battery CR2032)

230 V AC

Battery life:

3 ÷ 5 years

-

Input voltage tolerance:

-

-15 ÷ +10 %

Nominal frequency:

-

50 / 60 Hz

Nominal power consumption:

-

0,5 W

Number of operation modes:

-

5

Number of channels:

2

1

Transmission:

radio 868,32 MHz

Transmission way:

unidirectional

Coding:

addressing transmission

Maximum number of transmitters:

-

32

Range: up to 250 m in the open air

up to 230 m in the open air

Time adjustment:

-

1 s ÷ 18 hours (every second)

Optical signalling:

LED red diode

Receiver’s output clamps:

-

, N

Maximum output load:

-

250 W

Number of terminal clamps:

-

4

Section of connecting cables:

-

up to 2,5 mm

2

Ambient temperature range:

-10 ÷ +55 

o

C

Operating position:

free

Casing mounting:

wall plugs, double-sided 

adhesive tape

installation cable box Ø60 

mm

Casing protection degree:

IP20 (EN 60529)

Protection level:

III

II

Overvoltage category:

II

Pollution degree:

2

Surge voltage:

-

1 kV (EN 61000-4-5)

Dimensions:

90 x 80 x 11,5 mm

47,5 x 47,5 x 20 mm

Weight:

0,038 kg

0,040 kg

Reference standard:

PN-ETSI EN 300 220-1,

PN-ETSI EN 300 220-2

PN-EN 60669, PN-EN 60950,

PN-EN 61000

Reviews: