background image

ZAMEL

 Sp. z o.o.

ul. Zielona 27, 43-200 Pszczyna, Poland

tel. +48 32 449 15 00, +48 32 210 46 65, fax +48 (32) 210 80 04

www.zamel.com

, e-mail: matec@zamel.pl

plik: inst_zamel_gb_GPSY | modyfikacja: 07.06.2016

plik: inst_zamel_gb_GPSY | modyfikacja: 07.06.2016

A DRAFT OR A PHOTO OF THE HEATING CABLE WITH A SUPPLY CABLE AND ACCESSORIES

DESCRIPTION

Heating cables type GPSY are used against icing for stairs and ramps. They are laid under the 

outdoor surfaces. These cables must not be applied under asphalt. They are strongly mounted to 

the surface by means of mounting clips. The cables should be installed with a temperature regulator 

equipped with sensors.

The GPSY heating cables are designed to operate outdoor at 230 V AC nominal voltage and 20 W/m.

The heating cable with power supply cable is connected to 230 V AC by means of a temperature 

regulator.

GPSY heating cable – the set includes:

● one-sided power supply heating cable with power supply cable, 

● installation instruction with the Warranty Card.

Fig. Heating cable with supply cable

A temperature regulator 

is an essential ele-

ment used to control the GPSY heating cable 

temperature. It is used to connect the heating 

cable with the electric installation.

It is import ant to choose a temperature regula-

tor with regard to the heating cable power, its 

location place and with regard to the place of 

the measuring sensors.

Depending on the function the heating system 

with a temperature regulator shall realise, the 

following sensors are applied: temperature 

sensors, ice and snow sensors, temperature 

and humidity sensors.

The connection of the heating cable with a 

temperature regulator should be done in ac-

cordance with a diagram described in the 

temperature regulator manual instruction.

REMARKS

• During installation it is required to follow 

instructions included in the Heating Cable 

Manual Instruction.

• Thermoregulator’s installation must be done 

according to Thermoregulator Installation 

Manual.

• It is forbidden to mount the cable on pins, 

bolts,  screws  or  other  fixing  elements  that 

can damage the outer jacked of cables.

• The  cable installation surface must be 

smooth with no sharp edges or sharp fixing 

elements.

•  Heating unit cannot be mounted on non-uni-

form bases.

• The heating cables should be installed be-

tween  the  expansion  joints,  it  means  one 

heating cable module per one plate.

• The resistance heating cable should not be 

installed in places with permanent building.

•  The heating cable resistance must be meas-

ured at least twice: before starting the instal-

lation works, after arranging the heating ca-

ble on the floor, and before covering it with 

the top floor layer.

• Installation of the heating cable in the ambi-

ent temperature below + 5°C is not advis-

able. 

• Don’t cut the heating cable or its connection 

with power supply cable. Only the supply ca-

ble can be shortened.

•  The heating cable should not undergo exces-

sive strain and should be protected against 

sharp device damage.

• Heating unit must be supplied by means of 

a device from TN-S electric circuit with RCD 

(residual current device) of nominal power 

supply lower than 30 mA. The installation 

should have surge protection.

• The heating cables must not come into con-

tact, cross with each other or other cables 

- this could damage the insulation. The mini-

mum distance between the heating cables 

must not be less than 6 cm. 

•  It is required to make a draft or add pictures 

of the arrangement of the heating cable, 

power supply cable and the connection place 

of the heating cable with power cable („cold 

wire”). The draft or pictures are an integral 

part of the as-built documentation.

•  The device is not intended to be used by peo-

ple (children) with limited physical, feeling or 

psychic ability or people without experience 

or without the device knowledge unless it is 

under supervision of a person responsible for 

safety or according to installation manual.

•  Pay attention to children - they must not play 

with the device.

•  The radius of heating cable bending shall not 

be less than 10 times of its diameter.

•  The heating cable cannot be permanently im-

mersed in any liquid.

• The heating cable must be used in accord-

ance with manufacturer’s specifications.

• The cable is not designed to be applied un-

der asphalt surface.

TECHNICAL DATA

Heating cable TYPE

GPSY 9,5 ÷ 100 m long

Power supply voltage:

230 V AC / 50 Hz

Unit power: 

20 W/m

Operating temperature: 

80 

o

C

Supply type:

one-sided

Heating cable:

two-wire, shielded

The heating cable is ended with H05VV-F 3G1 power supply cable at one side

MATEC – ELECTRIC DE-ICING SYSTEMS

 

MANUAL INSTRUCTION

HEATING CABLE TYPE 

GPSY

, USED UNDER DRIVEWAYS AND OTHER TRANSPORT ROUTES FOR STAIRS AND RAMPS

230 V AC

RCD

protection device

L

 (black / brown)

N

 (blue)

PE

 (green-yellow )

brown

green-yellow 

blue

Temperature

controller

Supply cable 

of the one-sided 

supplied 

heating cable.

Fig. A connection diagram of a heating cable

by means of a temperature regulator

to the electrical installation

Heating

cable

Supply

cable

Reviews: