Mounting Manual

Exigo EAPFX & Turbine TFIX Ex Series

Mounting procedures are the same for all units in the Exigo and Turbine Ex series.

Contents of the Delivery

  The unit comes with 4 blind plugs already mounted. The front frame is fastened with 2 socket-head 

cap M6 screws.

Important Notes before Mounting

Improper installation and operation of the Ex unit will result in the invalidation of the warranty.

The enclosure/housing must not be opened when the unit is powered.

The installation and connection of Ex units may only be carried out by qualified/approved personnel.

General Mounting Considerations

When the Ex unit is mounted directly onto a wall or mounting plate, it shall rest only on the fastening points 

provided for this purpose. The surface must be even and flat.

The unit must be mounted on a surface to prevent access from the rear of the unit.

Do not use countersunk screws.

Due to the cabinet material, use as low a tightening torque as possible when mounting the 

unit to the surface (1.5 Nm max.)
Washers are recommended.

Do not use more than 2.5 Nm torque when fastening the 12 screws into the front frame.

On Mounting Plate or Column - recommended screws:  

M5 x 20 or 25 with Philips head DIN7985 or Torx head diameter: 10 mm.  

On Wall - recommended screws:

Panhead DIN7981 for plug or wooden wall, etc. Head diameter: 10.8 B5.5 x 38 or 45 mm.

EAPFX-6-V2

1023221616

EAPFX-1-V2

1023221611

1 Cable Gland  

M25 Ex e

1 Cable Gland  

M16 Ex e 

10 socket-head 

cap M6 screws

(+ 2 fastened to 

front frame)

1 Ex Unit

TFIX-1-V2

1008123110

TFIX-2-V2

1008123120

TFIX-3-V2

1008123130