Page 1/2
Lumento DX4 v2
4-channel constant voltage PWM dimmer in DIN rail for DC LED loads
ZDILDX4V2
TECHNICAL DOCUMENTATION
FEATURES
•
4
constant
voltage
configurable
channels
(combinable
independent channels, RGBW channel, RGB+W channels and
combinable TW channels)
•
1 relay to control the LEDs power supply or for independent use
•
Supports KNX Data Secure
•
Master Light control
•
External 12-40 VDC power supply
•
Manual output operation with push button and LED status indicator
•
Total data saving on KNX bus failure
•
Integrated KNX BCU (TP1-256)
•
Dimensions 67 x 90 x 79 mm (4.5 DIN units)
•
DIN rail mounting according to IEC 60715 TH35, with fixing clamp
•
Conformity with the CE, UKCA, RCM directives (marks on the right
side)
Figure 1: Lumento DX4 v2
GENERAL SPECIFICATIONS
CONCEPT
DESCRIPTION
Type of device
Electric operation control device
KNX supply
Voltage (typical)
29 VDC SELV
Voltage range
21-31 VDC
Maximum
consumption
Voltage
mA
mW
29 VDC (typical)
6.2
179.2
24 VDC¹
10
240
Connection type
Typical TP1 bus connector for 0.8 mm Ø rigid cable
External power supply
12-40 VDC
Operation temperature
0 .. +55 °C
Storage temperature
-20 .. +55 °C
Operation humidity
5 .. 95%
Storage humidity
5 .. 95%
Complementary characteristics
Class B
Protection class / Overvoltage category
II / III (4000 V)
Operation type
Continuous operation
Device action type
Type 1
Electrical stress period
Long
Degree of protection
IP20, clean environment
Installation
Independent device to be mounted inside electrical panels with DIN rail (IEC
60715)
Minimum clearances
Not required
Response on KNX bus failure
Data saving according to parameterization
Response on KNX bus restart
Data recovery according to parameterization
Operation indicator
The programming LED indicates programming mode (red) and test mode
(green). Color shift LEDs show the current color. Each output LED indicates
its status.
Weight
200 g
PCB CTI index
175 V
Housing material
PC FR V0 halogen free
¹ Maximum consumption in the worst-case scenario (KNX Fan-In model).
Programming/Test button: short press to set programming mode. If this button is held while plugging the device into the KNX bus, it enters the safe mode.
If this button is held for more than 3 seconds, the device enters the test mode. In order to perform a KNX Secure factory reset, while the device is in safe
mode, press the button for 10 seconds until the programming LED changes its state.
Programming/Test LED: programming mode indicator (red). When the device enters the safe mode, it blinks (red) every half second. The test mode is
indicated by the green color. During the start-up (reset or after KNX bus failure) and if the device is not in safe mode, it emits a red flash.
1. Power Supply LED
2. Colour shift control buttons
3. External power supply
4. Colour output LEDs
5. TW selection button
6. (not used)
7. Relay status LED
8. Relay control button
9. Power Supply Relay
10. Output channels
11. KNX connector
12. Programming/Test LED 13. Programming/Test button
14. Channel status LED
15. Channel control button
1
3 4 5
15
2
6
8
7
9
14 10
10
13 12 11