background image

Use, Care, and Installation Guide

www.zephyronline.com

Model number: 
Serial Number: 
Date of Purchase: 
Sales Dealer: 

JUN20.1001 © Zephyr Ventilation LLC.

Twister

AK8000BS

AK8000AS-ES

Tornado I

AK8100AS-BF

READ AND SAVE THESE INSTRUCTIONS

AK8000BS
AK8100AS-BF

AK8000AS-ES

Summary of Contents for Twister AK8000BS

Page 1: ...e www zephyronline com Model number Serial Number Date of Purchase Sales Dealer JUN20 1001 Zephyr Ventilation LLC Twister AK8000BS AK8000AS ES Tornado I AK8100AS BF READ AND SAVE THESE INSTRUCTIONS AK...

Page 2: ...www zephyronline com...

Page 3: ...ptions 7 Specifications 8 Electrical 9 Installing the Power Pack 10 FEATURES CONTROLS Slide Controls 11 MAINTENANCE Cleaning and Installing Filters 12 AK8000BS Recirculating Kit 13 Lights 14 TROUBLESH...

Page 4: ...the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie s...

Page 5: ...Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wi...

Page 6: ...s AK8000BS AK8100AS BF 2 Fluorescent light bulbs AK8000AS ES 1 Single internal blower pre installed 1 Hardware package HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation...

Page 7: ...0 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3...

Page 8: ...d maximum mounting height should be no higher than 36 It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mo...

Page 9: ...l exhaust must be ducted to the outside Use metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Some Ducting Options Installa...

Page 10: ...ne com Installation Specifications top front bottom side 4 1 8 5 3 8 3 3 4 10 5 8 5 7 8 1 1 16 10 1 2 11 13 16 26 9 16 27 9 16 27 9 16 25 3 4 9 3 8 8 11 16 11 3 16 11 3 16 10 5 16 1 5 16 15 18 15 16 1...

Page 11: ...ing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere ci...

Page 12: ...rt is needed see FIG 3 and FIG 4 6 Install duct work and seal with duct tape 7 Install electrical 8 Remove all packing materials before using Power Pack Switch power on and check for leaks around duct...

Page 13: ...f I is low speed II is medium speed and III is high speed LIGHTS BRIGHT DIM OFF 0 is off I is dim and II is bright 1 2 BLOWER ON OFF SPEED SELECTION 0 is off I is low speed II is medium speed and III...

Page 14: ...ess steel grain Cleaning Filters The aluminum mesh filters installed by the factory are intended to filter out residue and grease from cooking They need not be replaced on a regular basis but are requ...

Page 15: ...ed on top of the standard aluminum mesh filter and a return air vent is needed to direct air back into the kitchen The standard aluminum mesh filter is intended to capture residue from cooking and the...

Page 16: ...bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately the diame...

Page 17: ...in place 2 Damaged blower wheel 2 Change the blower 3 The hood is not secured in place 3 Check the installation of the hood The motor is working but the lights are not 1 Defective light bulb 1 Change...

Page 18: ...70W THERMALLY PROTECTED Power Consumption BLUE BLUE BROWN BROWN GREY YELLOW YELLOW RED WHITE WHITE WHITE WHITE WHITE BLACK BLACK BLACK BLACK GREEN GREEN BODY BODY CIRCUIT DIAGRAM B W B W B W Model AK8...

Page 19: ...00AS ES Z0B0036 Aluminum Mesh Filter AK8000BS AK8000AS ES 50200022 Hybrid Baffle Filter AK8100AS BF 50210030 Optional Accessories Liner 30 AK0800AS Liner 36 AK0836AS Recirculating Kit AK8000BS ONLY ZR...

Page 20: ...ll the Products After the first year from the date of your original purchase you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR...

Page 21: ...ts After the first year from the date of your original purchase you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE A...

Page 22: ...our new range hood at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways than one IT S IMPORTANT Ensures w...

Page 23: ...allation www zephyronline com Num ro de mod le Num ro de s rie Date d achat D taillant JUN20 1001 Zephyr Ventialtion LLC AK8000BS AK8100AS BF AK8000AS ES Twister AK8000BS AK8000AS ES Tornado I AK8100A...

Page 24: ...www zephyronline com...

Page 25: ...le conduit 7 Sp cifications de la hotte 8 lectricit 9 Installation du bloc d alimentation 10 COMMANDES Commandes par curseur 11 ENTRETIEN Nettoyage et changement des filtres 12 Ensemble de reprise d a...

Page 26: ...convenant au type et la quantit de nourriture que vous pr parez AVERTISSEMENT POUR R DUIRE LES RISQUES DE BLESSURE LORS D UN INCENDIE SUR LA SURFACE DE CUISSON a TOUFFEZ LES FLAMMES avec un couvercle...

Page 27: ...cte le Code national de l lectricit la plus r cente dition du ANSI NFPA 70 ou des normes du CSA C22 1 94 le Code canadien de l lectricit section 1 la plus r cente dition du code C22 2 No 0 M91 ainsi q...

Page 28: ...S AK8100AS BF 2 Ampoules fluorescente AK8000AS ES 1 Ventilateur interne simple pr install 1 Trousse de quincaillerie Ventouse 1 Capuchons 3 M4 x 1 4 M4 x 1 1 2 4 CONTENU DE LA TROUSSE DE QUINCAILLERIE...

Page 29: ...is rect droit circ droit rect coude 90 rect coude 45 rect coude plat 90 circ coude 90 coude 45 Sous total colonne 1 Longueur maximale du conduit d a ration Pour un mouvement d air convenable la longue...

Page 30: ...teurs sont n cessaires installez les le plus loin possible de l ouverture et le plus loign possible l un de l autre La hauteur de montage minimale entre la hotte et la cuisini re ne devrait pas tre mo...

Page 31: ...tilis e N utilisez que des conduits en m tal pour cloison simple Fixez toutes les pi ces du conduit avec des vis t le et isolez tous les joints avec du ruban adh sif en toile ou de ruban r flecteur ce...

Page 32: ...Installation Sp cifications de la hotte dessus devant bas c t 4 1 8 5 3 8 3 3 4 10 5 8 5 7 8 1 1 16 10 1 2 11 13 16 26 9 16 27 9 16 27 9 16 25 3 4 9 3 8 8 11 16 11 3 16 11 3 16 10 5 16 1 5 16 15 18 15...

Page 33: ...tions nationaux ou locaux en vigueur Alimentation lectrique Cet appareil requiert une alimentation lectrique de 120V 60Hz Il doit tre connect un circuit terminal individuel d ment mis la terre prot g...

Page 34: ...FIG 4 6 Installez le conduit et scellez l aide de ruban adh sif en toile 7 Proc dez l installation lectrique 8 Enlevez tous les emballages avant d utiliser le bloc d alimentation Mettez la hotte en ma...

Page 35: ...itesse LUMI RES FORTES VEILLEUSE TEINTES 0 les lumi res sont teintes I elles sont forte intensit et II elles sont en veilleuse 1 2 0 I I I I I I Ventilateur Marche Arr t Choix de vitesse 1 Lumi res Fo...

Page 36: ...iltres de maille d coratifs et filtres de maille m talliques Les filtres ont pour fonction de filtrer les r sidus et la graisse r sultant de la cuisson Bien que les filtres ne doivent jamais tre rempl...

Page 37: ...rification d air est choisie un filtre charbon doit tre install sur le filtre de maille m tallique standard et un syst me de reprise d air est n cessaire pour renvoyer l air dans la cuisine Les filtre...

Page 38: ...e des aiguilles d un montre Note les ampoules ne se d vissent pas apr s une rotation de 60 degr s elles s arr tent et tombent de la douille Lorsqu il est difficile de retirer les ampoules apr s un usa...

Page 39: ...mplacez le condensateur L appareil vibre 1 Le moteur n est pas bien fix en place 1 Fixez solidement le moteur en place 2 La roue du ventilateur est endommag e 2 Remplacez le ventilateur 3 La hotte n e...

Page 40: ...ampe Max 13Wx2 Ventilateur 70W PROTECTION THERMIQUE Consommation d energie BLEU BLEU BRUN BRUN GRIS JAUNE JAUNE ROUGE BLANC BLANC BLANC BLANC BLANC NOIR NOIR NOIR NOIR VERT VERT CORPS CORPS SCHEMA DE...

Page 41: ...S ES 50200022 Filtre de maille d coratif AK8100AS BF 50210030 Accessoires facultatifs Rev tement de protection 30 AK0800AS Rev tement de protection 36 AK0836AS Ensemble de reprise d air AK8000BS seule...

Page 42: ...v ou r install Un an apr s la date d achat originale du Produit vous tes galement responsable de tous les frais de main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATIO...

Page 43: ...l Un an apr s la date d achat originale du Produit vous tes galement responsable de tous les frais de main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATION DE R PARER...

Page 44: ...ration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Cet enregistrement rapide est utile bien des gards C EST IMPORTANT Il assure la couverture de votre garantie si vous avez...

Reviews: