POWER SUPPLY SOURCES
S
ERIES
SSG
SSG 1,5 SSG2,5 & SSG5
Instruction Manual
July 12, 2006
SSG-0101
All the information contained in this document may be modified without prior warning.
Page 1: ...POWER SUPPLY SOURCES SERIES SSG SSG 1 5 SSG2 5 SSG5 Instruction Manual July 12 2006 SSG 0101 All the information contained in this document may be modified without prior warning...
Page 2: ...suitable recycling bin or return it to the supplier in the original packaging of the new batteries Consult the new battery instructions to obtain more information on this Do not dispose of batteries...
Page 3: ...3 Checking the power supply source 3 Checks prior to installation 4 Protection against transient interferences 4 Cleaning 4 Mounting Series MPS 5 2 LED Description and Operation 6 Features of SSG Powe...
Page 4: ...element 1 If after unpacking the Series SSG power supply source and making a visual inspection you find that it has been damaged in any way YOU SHOULD NOT carry on with installation but rather you sh...
Page 5: ...nterferences Just like all electronic equipment this system may function irregularly when subject to electrical discharges Although no system is completely immune from electrical discharges a proper E...
Page 6: ...ed on the wall and mark the position of the screw holes making sure that the center one is leveled The following illustration shows the box and the screw holes through the back Do not use the rear box...
Page 7: ...ms 6 FRONT PANEL 2 LED DESCRIPTION AND OPERATION INTERNAL LEDS GENERAL FAULT SERVICE PRIMARY POWER SUPPLY FAULT BATTERY CHARGER FAULT BATTERIES NOT CONNECTED FAULT LOW BATTERY WARNING EARTH SHUNT SYST...
Page 8: ...he primary power supply conditions The two source models are similar they are composed of a power supply module of 45W 65W and 2 x 65W for supply sources SSG1 5 SSG2 5 and SSG5 respectively and an ele...
Page 9: ...ch is indicated after a delay of some 8 minutes in order to prevent failures due to intermittent blackouts Fault Relay Operation Connector J4 FAULT with three terminals Terminal 1 Left C common Termin...
Page 10: ...ative OUTPUT 2 PSO2 Output 2 positive PSO2 Output 2 negative FAULT RELAY FAULT C Fault relay common FAULT NC Contact normally closed FAULT NO Contact normally open MAINS IN MAINS IN Equipment earth MA...
Page 11: ...f a connection fault or else because they are at low discharge level and the control disconnects them for protection It blinks when the batteries are at the last level of discharge before disconnectio...
Page 12: ...nt per output 630mA SSG 1 5 1 A SSG 2 5 2 A SSG 5 Battery charge current 300mA 7 Amp hour 600mA 17 Amp hour Charges batteries to 80 in less than 24 hours and to 100 in less than 48 hours Faulty Relay...