Operating Manual TMU100V

 

updated: 2018-11-12 / sm 

 

 

 

 

TMU100V 

12100-0702-01 

Page

 

1 / 6 

www.ziehl.de 

- Measuring- Transducer for Potentiometers 

 
 

 

 
 

   

 

 

 

Summary of Contents for TMU100V

Page 1: ...ehl de www ziehl de Temperature Relays and MINIKA Mains Monitoring Digital Panelmeters MINIPAN Switching Relays and Controls Measuring Transducers Grid and Plant Protection Operating Manual TMU100V updated 2018 11 12 sm TMU100V 12100 0702 01 Page 1 6 www ziehl de Measuring Transducer for Potentiometers ...

Page 2: ...nd short description Model TMU100 Pt100 measuring transducers are suitable for measuring temperatures with sensors Pt100 RTD Zero and Full scale can be freely set within the whole range 199 850 C To do this only resistors with the according value or a Pt 100 decade is connected The adjustment is done by pressing a button The built in universal power supply AC DC 24 240 V allows the connection to a...

Page 3: ...temperature permissible when installing in switching cabinet Make sure sufficient space to other equipment or heat sources If the cooling becomes more difficult e g through close proximity of apparatus with elevated surface temperature or hindrance of the cooling air the tolerable environmental temperature is diminishing To use the equipment flawless and safe transport and store properly install a...

Page 4: ...ro Wait until LED power starts blinking and release button Leave commissioning mode by pressing buttons Zero and Full scale simultaneously Commissioning mode is finished automatically after 10 min Set values remain stored also when power is switched off 7 2 Adjusting of Zero Simulate temperature for zero at input of TMU100V with a resistor or a decade for Pt 100 Resistance see table in this manual...

Page 5: ... Fault burden 250 Ω burden 250 Ω 0 3 of the current For parameter error Full scale approx 22mA 12V are output For parameter error zero approx 0mA 0V are output Test conditions EN 61010 1 Rated impulse voltage 4000 V Overvoltage category II reinforced insulation Pollution degree 2 Rated insulation voltage Ui 250 V On period 100 EMC tests Emission EN 61000 6 3 Immunity EN 61000 6 2 Installation cond...

Page 6: ...t part of delivery Weight approx 130 g Subject to technical modifications 10 Housing Type V2 Dimension in mm 1 Oberteil cover 2 Unterteil base 3 Riegel bar for snap mounting 4 Plombenlasche latch for sealing 5 Frontplatteneinsatz front panel 6 Kennzeichen für unten position downward 7 Riegel bei Wandbefestigung mit Schrauben Riegelbohrung Ø 4 2 mm for fixing to wall with screws Ø 4 2 48 58 45 3 61...