background image

Zip Autoboil - Installation & Operating Instructions - 81439 - May 2012 v1.02 

Page 1 of 12

Installation and Operating Instructions

Zip Autoboil

Instant boiling water 

11052 Zip Autoboil 15 Litre White

11051 Zip Autoboil 15 Litre Stainless Steel

12052 Zip Autoboil 25 Litre White

12051 Zip Autoboil 25 Litre Stainless Steel

04052 Zip Autoboil 40 Litre White

04051 Zip Autoboil 40 Litre Stainless Steel

Summary of Contents for 11052 Zip Autoboil 15 Litre White

Page 1: ...and Operating Instructions Zip Autoboil Instant boiling water 11052 Zip Autoboil 15 Litre White 11051 Zip Autoboil 15 Litre Stainless Steel 12052 Zip Autoboil 25 Litre White 12051 Zip Autoboil 25 Litr...

Page 2: ...Page 2 of 12 Zip Autoboil Installation Operating Instructions 81439 May 2012 v1 02 Intentionally left blank...

Page 3: ...ts 4 Installation Procedures 5 Step 1 Positioning 5 Step 2 Fastening 5 Step 3 Connecting 6 a Plumbing 6 b Venting 6 c Electrical 6 Step 4 Assembling 6 Step 5 Commissioning 6 Wall Mounting Template Dim...

Page 4: ...abrasive cleaners to clean the case of the heater Frost protection If this heater is located where ambient air temperature could fall below 5 C when the heater is not in use do not turn off the applia...

Page 5: ...ng board or drip tray Position the base of the tap to be not less than 200 mm above the draining board height should be increased only if essential for filling larger vessels Provide clearance for ser...

Page 6: ...h to the wall as shown and plumb away to waste c Electrical For concealed electrical connection connect a power cable through the rear access opening of the heater to the terminal block within the hea...

Page 7: ...Zip Autoboil Installation Operating Instructions 81439 May 2012 v1 02 Page 7 of 12 Wall Mounting Template Dimensions Electrical Diagram Wall template for 15 litre 25 litre 40 litre models...

Page 8: ...al adjustment Contact Zip authorised agent Warning this appliance must be earthed Following remedial service the earthing continuity of the heater must be checked by a qualified technician using an ap...

Page 9: ...safe filling of cups and mugs To fill larger vessels such as teapots and saucepans rotate the tap 180 degrees and depress it until it locks into a horizontal position Boiling water will flow until the...

Page 10: ...ern Float S Nut Kit 10 90495 Banjo Screw Kit 11 90110 Fascia Light Kit 12 90501 Tap Top Kit 13 90499 Fascia Lens Kit 14 90494 Metering Tube Kit 2400 w 90527 Metering Tube Kit 3600 w 90526 Metering Tub...

Page 11: ...Zip Autoboil Installation Operating Instructions 81439 May 2012 v1 02 Page 11 of 12 Spare Parts 1 20 19 18 21 17 16 14 13 15 12 11 9 8 7 6 5 4 3 2 4 4 8 8 4 10 17...

Page 12: ...2200 Postal Locked Bag 80 Bankstown 1885 Australia Website www zipheaters com Facsimile 02 9796 3858 Telephone 02 9796 3100 Free Call 1 800 638 633 Contact Details As Zip policy is one of continuous p...

Reviews: