background image

804545 03.17 v1.00 

Page 1 of 16

Zip Autoboil

303052 Zip Autoboil 3 Litre White
303051 Zip Autoboil 3 Litre Stainless Steel
305052 Zip Autoboil 5 Litre White
305051 Zip Autoboil 5 Litre Stainless Steel
307052 Zip Autoboil 7.5 Litre White
307051 Zip Autoboil 7.5 Litre Stainless Steel

Installation and Operating Instructions

Summary of Contents for 303051

Page 1: ...boil 3 Litre White 303051 Zip Autoboil 3 Litre Stainless Steel 305052 Zip Autoboil 5 Litre White 305051 Zip Autoboil 5 Litre Stainless Steel 307052 Zip Autoboil 7 5 Litre White 307051 Zip Autoboil 7 5 Litre Stainless Steel Installation and Operating Instructions ...

Page 2: ... reduced physical sensory or mental capabilities or lack of expe rience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety For products sold in Europe this appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and ...

Page 3: ...heater from the power supply Do not use strong corrosive or abrasive cleaners to clean the case of the heater Frost protection If this heater is located where ambient air temperature could fall below 5ºC when the heater is not in use do not turn off the appliance electrically This safeguide does not offer the same protection to the connecting pipework and fittings The ambient temperatures this uni...

Page 4: ...cal connections Concealed connections are preferred for superior appearance Step 1 Positioning Position the heater so the tap will drain on to a draining board or drip tray Position the base of the tap to be not less than 300 mm above the draining board height should be increased only if essential for filling larger vessels Provide clearance for service access of not less than 100 mm top 150 mm le...

Page 5: ...ater It is recommended that the heater be installed with a stop cock which allows it to be isolated from the mains supply for servicing Water pressure requirements Minimum 70 kPa maximum 700 kPa 3 2 Venting A vent at the base of the heater must be plumbed to a safe visible location as under certain conditions it may discharge cold or boiling water and or steam For exposed vent plumbing connect ven...

Page 6: ...to the green terminal block on the PCB Check that the earth is connected through the PCB to the chassis with an ohm meter Warning Do not connect both options It is essential that the flex and plug cable is removed from the PCB if the concealed connection is used Otherwise the GPO plug will become live Step 4 Installing Filter Guide Assemble the filter guide provided with the unit make sure it is l...

Page 7: ...ilter NOTE For safe operation the filter cartridge should be replaced every 6 12 months or earlier if you notice a persistent reduction in water pressure from the appliance or an unpleasant taste or odour in the water Refer to Filter Replacement section on page 21 for instructions of changing filter Installation Procedures Step 7 Commissioning Filter Flush Calibrate Remove Plug Fig 1 Warning Do no...

Page 8: ...ckwards into the locked open position fig 2 and allow the tank to fill until water flows from the tap outlet 6 Once the water is available from the tap turn off the mains water and close the tap outlet 7 Turn on the power to the unit water must be in the tank 8 Touch the white circle next to the left of the Tick to Continue For screen operation see the section on Menu Operation 9 Boiling Calibrati...

Page 9: ...uttons Move to the next item able to be highlighted Move to the previous item able to be highlighted Confirm menu selection Move to the previous menu Perform one of 3 functions 1 Move to the menu titled by the highlighted item 2 Select the currently highlighted item to adjust it 3 Confirm the value of a selected item Increment the item selected Decrement the item selected 2 Home Screen Content 2 1...

Page 10: ...u Filter Indication Days remaining of filter life Shown red filter needs replacement Sleep Mode Indication Unit will enter sleep mode at the time shown Unit will enter sleep mode when it is dark All sleep saving modes are disabled 2 2 Sleep Mode Trigger Indication Unit will exit sleep mode at the time shown Unit will exit sleep mode when ambient light returns to normal bright room Menu Operation ...

Page 11: ...u Select on the home screen to navigate to the main menu Choose Settings and select Choose an option and select 2 3 Sleep Override Mode Awake time remaining Unit will return back to sleep mode after this time Main Menu Settings Menu Menu Operation ...

Page 12: ...on to prevent excessive steam release or high energy usage see section 4 2 3 3 Settings Sleep Modes From the settings menu choose Sleep Modes and select Choose Sleep Trigger and select and to select the trigger for the unit to enter its sleep mode Confirm using and return to the previous menu Disabled the unit will not enter its sleep mode the unit will use the on off timer settings to enter and e...

Page 13: ...timer settings for the 2 weekend days simultane ously Adjust on off timer settings for the 7 days separately Weekdays Weekends Individual Days 3 3 3 Timer Settings Individual Days Settings Choose item and adjust value then to confirm 3 4 Settings Filter From the settings menu choose Filter and select 3 4 1 Internal External Filters Choose Internal or External and select Choose one of the following...

Page 14: ...nu and on the home screen are based on these 2 parameters This action will reset the filter usage counter A re minder is shown to flush the new filter before doing this see page 21 Filter Replacement Select to continue after flushing Choose Continue and select to reset the filter usage counter The log shows the dates that the filter usage counter was reset and the days used before the reset was pe...

Page 15: ...anged requiring recalibration of the boiling point Incorrect boiling calibration points may cause excessive steam vent releases or increased energy usage Boiling calibration is recommended when the temperature setting is close to 100 C section 3 2 From the install menu choose Continue and select The unit will heat the water for boiling calibration This may take several minutes depending on the ini...

Page 16: ...ct 5 2 Info Current Fault From the info menu choose Current Fault 6 Service Menu Note The service menu is used by technicians only for diagnostic purposes Menu Operation 5 Info Menu Select on the home screen to navigate to the main menu Choose Info and select Choose value then select ...

Page 17: ...804545 03 17 1 00 Page 17 of 24 Wall Mounting Template Dimensions ROG QOHW 9HQW WHUQDO 3OXPELQJ OHFWULFDO LULQJ QWHUQDO 3OXPELQJ 3RVLWLRQLQJ SLQ ...

Page 18: ... 19 90100 Grommet Cistern to Tank 20 94458 Overload 21 94459 Side release plug 22 94460 Seal transfer tube Item Kit Number Description 23 94483 Metering Tube 1 5 3 Ltr 94461 Metering Tube 5 7 5 Ltr 24 94462 Element assy 1500W 1 5 3 94463 Element assy 2400W 5 7 5 25 94484 Bush Vent assy 3 ltr 94485 Bush Vent assy 5 ltr 94486 Bush Vent assy 7 5 ltr 26 94487 Inlet assy 27 94488 AB Fascia Kit 94489 AB...

Page 19: ...804545 03 17 1 00 Page 19 of 24 Exploded View Diagram ...

Page 20: ...ve turned off Blocked filter blocked meter tube blocked strainer jammed ball valve assembly Check filter flush valve position see Step 7 page 8 Check filter is inserted correctly see page 21 Check water supply valve Contact Zip authorised agent Water not boiling Incorrect temperature setting Incorrect sleep mode setting No power Faulty thermostat faulty element faulty cutout Check temperature sett...

Page 21: ...ion in water pressure from the appliance or an unpleasant taste or odour in the water To Replace Filter Turn the filter anti clockwise fig 1 and pull the cartridge down fig 2 Have an absorbent cloth ready as a small amount of water will be released as the filter is removed The cartridge should release from the filter head Replace with a new filter by gently pushing up engaging the key and turning ...

Page 22: ... not use strong corrosive spray or abrasive cleaners Clean the case with a soft cloth or sponge and mild soapy water Dispose of the filter cartridge responsibly Use only Zip Filter in this product to ensure effective filtration and operation Replacement filter cartridges can be obtained through plumbing suppliers or directly from Zip Filter replacement instructions are included with the filter car...

Page 23: ...804545 03 17 1 00 Page 23 of 24 NOTES ...

Page 24: ...ntinuous product improvement changes to specifications may be made without prior notice Images in this booklet have been modified and may not be true representations of the finished goods The standard cup referred to in this publication is 167 ml 6 fl oz 2017 Zip Heaters AUST Pty Ltd All Rights Reserved The terms Zip Hydroboil Autoboil Econoboil Power Pulse GlobalPlus MicroPurity are trademarks of...

Reviews: