background image

804546 03.17 1.00

 

Page 1 of 24

Zip Hydroboil

 

 

 

 

303062  Zip Hydroboil  3 Litre White 

 

 

 

 

303061  Zip Hydroboil  3 Litre Stainless Steel  

 

 

 

 

305062  Zip Hydroboil  5 Litre White  

 

 

 

 

305061  Zip Hydroboil  5 Litre Stainless Steel  

 

 

 

 

307062  Zip Hydroboil  7.5 Litre White  

 

 

 

 

307061  Zip Hydroboil  7.5 Litre Stainless Steel

Installation and Operating Instructions

Summary of Contents for 303061

Page 1: ...il 3 Litre White 303061 Zip Hydroboil 3 Litre Stainless Steel 305062 Zip Hydroboil 5 Litre White 305061 Zip Hydroboil 5 Litre Stainless Steel 307062 Zip Hydroboil 7 5 Litre White 307061 Zip Hydroboil 7 5 Litre Stainless Steel Installation and Operating Instructions ...

Page 2: ...ing children with reduced physical sensory or mental capabilities or lack of expe rience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety For products sold in Europe this appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack o...

Page 3: ...sive cleaners to clean the case of the heater Frost protection If this heater is located where ambient air temperature could fall below 5ºC when the heater is not in use do not turn off the appliance electrically This safeguide does not offer the same protection to the connecting pipework and fittings The ambient temperatures this unit must operate within is 5ºC 50ºC This heater is intended only f...

Page 4: ... the base of the tap to be not less than 215 mm above the draining board height should be increased only if essential for filling larger vessels Provide clearance for service access of not less than 100 mm top 150 mm left 20 mm right Mark corner positions for the heater on the wall so as to position the paper mounting hole template Step 2 Fastening Position mounting hole template on wall and drill...

Page 5: ... 63 Swivel Elbows Cold water pipes must be flushed before connection to the inlet Any clogging due to sediment or fines will adversely affect the operation of the heater It is recommended that the heater be installed with a stop cock which allows it to be isolated from the mains supply for servicing Water pressure requirements Minimum 70 kPa maximum 700 kPa A 500kPa pressure limiting valve is part...

Page 6: ...utlet within 1500 mm from the heater with adequate power for the unit For a concealed electrical connection disconnect the pre fitted flex and plug cable at the PCB connector and discard Connect the concealed power cable through the rear access opening to the green terminal block on the PCB Check that the earth is connected through the PCB to the chassis with an ohm meter Warning Do not connect bo...

Page 7: ...ugh 90 until fully engaged 20mm Step 6 Installing Filter Installation Procedures Fit the case wrapper to unit as shown in the picture below Note make sure the filter guide has already been installed before installing the cover Step 5 Installing the Cover 1 Fit cover to the heater 2 Use screws and bolts provided to fasten case wrapper onto unit Special Notes Ensure the silicon outlet tube is correc...

Page 8: ... outlet note it may have the safety lock feature enabled Push the red safety lock button on the right hand side of the unit while pulling the tap lever backwards to latch it open see fig 2 and next section for operating procedure Turn the power on the element will not be turned on at this stage there is no need to have water covering the element yet Touch the blue Commission button to commence Tou...

Page 9: ...hows the boiling calibration status while it heats the water to boiling point The water temperature is shown in the first parameter It takes about 5 minutes to boil the water When calibration is complete the normal operating home screen will appear see next section on menu operation The tank will then commence filling and heating Boiling water will be maintained thereafter Initial heating and fill...

Page 10: ...tor is shown Warning The unit is now capable of dispensing boiling water without the safety feature Dispensing Boiling water Zip Hydroboil is fitted with a safety two way cool touch safety tap for instant boiling water Normal operation for filling cups and small containers To activate the tap press the safety button on the right side of the control panel and while holding the button in gently push...

Page 11: ...em Selected Unselected item Sleep Mode Sleep When Sleep if no water used time shown Sleep when dark after 10s of darkness Sleep at time shown Sleep disabled no sleep trigger Wake When Wake when water is used Wake when it is light Wake at time shown Force wakeup sleep override Unit will remain awake for the time shown Sleep after time remaining Touching these icons will show more details and allow ...

Page 12: ...ocked can dispense water This is the red lock button on the right side of the tap see page 10 Operating Procedure Energy Usage Energy used today kWh d The amount of energy used for the given day is shown below the icon It accumulates through the day and is reset to zero at midnight Fault Indicator Touch the indicator for further information No faults Shown Red Faults exist 1 1 HOME SCREEN SUB MENU...

Page 13: ...e Sleep Trigger as Timer to use this option see section 2 3 1 2 2 SETTINGS TEMPERATURE The water temperature can be adjusted as desired The default value is 98 0 C A higher value will consume more energy and may cause unwanted steam For values above 95 C a boiling calibration is recommended see section 3 2 From the home screen touch Tem perature Touch the Inc Dec to adjust the water temperature 2 ...

Page 14: ...iently adjusted in groups Everyday Weekdays and Weekends After adjusting a group an individual day can be adjusted or checked by choosing the Individual days option Everyday Set all 7 days simultaneously Weekdays Adjust Mon to Fri simultaneously Weekends Adjust Sat Sun simultaneously Individual Days Adjust Check each day sepa rately Choose one of the four options groups to show the following scree...

Page 15: ...outlet at 0 5L min Touch Stop when complete Touch Next after flushing As prompted return the filter valve to the Filtered position Fig 2 on page 8 and then touch Done Touch Done after flushing is completed Menu Operation Press Continue to reset the filter counter 2 4 3 SETTINGS FILTER LOG From the home screen touch Filter Log This is a record of when the filter was changed 3 INSTALL MENU From the ...

Page 16: ...ration The unit will heat the water during calibration This may take several minutes depending on the water temperature When it completes the install menu will be shown 3 3 INSTALL FILTER FLUSH This allows the filter flush steps to be performed From the home screen touch Filter Flush Follow the same sequence provided in section 2 4 2 Replace for the flushing steps It is logical to reset the filter...

Page 17: ...804546 03 17 1 00 Page 17 of 24 Wall Mounting Template Dimensions ROG QOHW 9HQW WHUQDO 3OXPELQJ OHFWULFDO LULQJ QWHUQDO 3OXPELQJ 3RVLWLRQLQJ SLQ ...

Page 18: ...ipping without excessive steam Requires boiling calibration Incorrect filter flush valve setting Incorrect filter insertion Internal adjustment Perform boiling calibration see section 3 2 Check filter flush valve position see step 7 page 8 Check filter is inserted correctly see step 7 page 7 Contact Zip authorised agent Sleep Wakes incorrectly when room is light dark Requires light calibration Inc...

Page 19: ...or earlier if you notice a persistent reduction in water pressure from the appliance or an unpleasant taste or odour in the water To Replace Filter Turn the filter anti clockwise fig 1 and pull the cartridge down Have an absorbent cloth ready as a small amount of water will be released as the filter is removed The cartridge should release from the filter head Replace with a new filter by gently pu...

Page 20: ...let 16 94456 Cistern Gasket 17 94509 Cistern Lid HB 18 93118 Elbow Stem 1 4 19 90100 Grommet Cistern to Tank 20 94458 Overload Item Kit Number Description 21 94459 Side release plug 22 94460 Seal transfer tube 23 94510 Metering Tube 24 90045 Element assy 1500W 1 5 3 90085 Element assy 2400W 5 7 5 25 94484 Bush Vent assy 3 ltr 94485 Bush Vent assy 5 ltr 94486 Bush Vent assy 7 5 ltr 26 94511 Inlet a...

Page 21: ...804546 03 17 1 00 Page 21 of 24 Exploded View Diagram ...

Page 22: ...e our environment we ask that you dispose of this product correctly Please contact your local city council for collection centre details Cleaning Cleaning Case Do not use strong corrosive spray or abrasive cleaners Clean the case with a soft cloth or sponge and mild soapy water ...

Page 23: ...804546 03 17 1 00 Page 23 of 24 NOTES ...

Page 24: ...ntinuous product improvement changes to specifications may be made without prior notice Images in this booklet have been modified and may not be true representations of the finished goods The standard cup referred to in this publication is 167 ml 6 fl oz 2017 Zip Heaters AUST Pty Ltd All Rights Reserved The terms Zip Hydroboil Autoboil Econoboil Power Pulse GlobalPlus MicroPurity are trademarks of...