background image

804053UK CS Res Quick Start Guide June 2016 - V3.01

Quick Start Guide

• 

Before proceeding, read the Installation instructions and User manual.

• 

Check all the components are present and correct.

• 

Check that you have all the necessary tools.

• 

Ensure the under-counter cupboard floor can support the product weight when full 

of water,(check the specifications in the Installation instructions and allow an extra 

5-8kg when full of water).

Note

 

This quick start guide must be read in conjunction with the Installation instructions 

and User manual.

Step 2- 

Cut cupboard holes and fit the air vent ducts.

Ventilation

Parts supplied

Description

Parts supplied

Description

1 x HydroTap

®

G4* 

Classic, Elite 

or 

#

Arc / Cube

#

(inc. Tube kit)

1 x User manual and 

1 x Quick start guide

1 x Installation 

instruction

1 x

Command-

Centre

TM

 with air 

and water filters

1 x 

CO

2

 gas cylinder 

assembly

2 x Outlet vent

1 x Inlet vent

1 x 

Mains water 

connection hose

801599 - HydroTap User Guide - Nov 2013 UK - V1.05

Page 1 of 20

ZIP HydroTap

User Guide

®

Tap Operation...................(Pages 2-5)

LCD Screen & Menu .......(Pages 6-18)

Maintenance.................... (Pages 18-20)

Date of Installation.........

Affix Model Number Label 

Here

 801599

BC160/125G4

BC240/175G4

BCH160/125G4

BCH240/175G4

AV160/125G4

AN160/125G4

AV240/175G4

AN240/175G4

801600 - Zip Quick Start Guide - October 2013 - V1.06

Parts Supplied

Description

Parts Supplied

Description

1 off

Hydrotap Tap

and hoses

Duct kit

1x Air Duct

1 x Mounting 

plate

1 off

Undersink Unit 

with air and water-

filter

Vent kit

1 x Kickboard 

louvre

1 x Door vent 

louvre

1 x front vent grill

1 x Restrictaflow 

valve and Tee 

piece for Mixer 

Taps

1 off

HydroTap 

Booster heater 

and hoses

(Supplied with 

240/175 models)

1 off Mains water 

connection hose

QUICK START GUIDE

Note: This quick start guide must be read in conjunction with 

the main installation and user instructions 

• 

Before proceeding, read the installation and user instructions

• 

Check all the components are present and correct.

• 

Check that you have all the necessary tools

• 

Ensure the underbench can support the product weight when full of water,                                   

(Check the specifications in the main book and allow an extra 5-8kg when full. )

Before installing ensure the following have been provided at 

the installation site:

• 

Sufficient space in the cupboard to install all of the undersink units in accordance 

with these Installation Instructions. Refer to technical specification for dimensions. If 

required, make allowance for a booster heater. (Refer to the main book, for detailed 

installation instructions). 

• 

A potable water supply connection with isolating valve inside the cupboard within 

reach of the flexible braided hose and positioned so that the connection point and the 

stop cock will not be obstructed when all the undersink units are installed. 

• 

For Zip HydroTap 160/125 &160/175 models, a 220-240Vac, 10A GPO will be 

required. For Zip HydroTap 240/175 models, two 220-240Vac, 10A GPOs will be 

required. (One GPO is for the Zip HydroTap and the other for the Booster heater).                                                                                                                         

NOTE: Check the cable lengths and outlet positions before proceeding. 

• 

A potable cold water supply with a minimum working pressure of 172kPa and a 

maximum working pressure of 700kPa connected via an isolation valve. 

• 

For the mains pressure All-IN-ONE, both a hot and cold water supply will be required.

• 

The undersink appliances must be mounted in upright positions as shown in the 

diagrams. 

IMPORTANT!

  Do not proceed with the installation if these 

requirements are not met.

STEP 1- 

Prepare and fit the Taps

Hole positioning: 

Position the tap such that it dispenses into 

the sink bowl with ample clearance for a cup or tea pot. Alternatively, 

the tap could be mounted away from the sink using a Zip Font, avail-

able as an accessory.

Apply a light smearing of silicon sealant 

on the underside of the upper spacer to 

ensure a watertight fi t.

For HydroTap and Mixer taps 

cut a 35mm hole in the bench / sink top.

BENCH TOP

Ø35mm

HydroTap Tap

Mixer Tap 

4-in-1

 

(If required)

NUT

LOWER RUBBER 

WASHER

UPPER 

RUBBER 

WASHER

WASHER

BRAIDED 

HOSE x 3

UPPER RUB-

BER WASHER

LOWER RUB-

BER WASHER

WASHER

NUT

White Hose

Ext. Mains

Blue band

Mixer  IN
Red band

Mixer Out 

O-RING

BASE 

BLOCK  

SPIDER

BASE 

BLOCK 

NUT

USB 

CABLE

ALL 

THREAD 

ROD

NOTE: feed each of 

the tubes and elec-

trical cable evenly in 

between the legs of 

the BASE BLOCK 

SPIDER.

All-In-One Tap 

(If required)

For AIO mains and vented Taps

Cut a 50mm hole in the bench / sink top.

NOTE: make sure the tap location will allow the nozzle to drain into the sink. 

SINK TOP

50mm

ALL THREAD 

ROD

STAINLESS 

STEEL  

WASHER

SPIDER 

CLAMP

NUT

BLACK 

PLASTIC 

SPACER

NOTE: feed each of the three tubes and 

electrical cable evenly in between the legs of 

the SPIDER CLAMP when installing. 

Fit the 

STAINLESS STEEL           

WASHER, 

SPIDER CLAMP, 

AND 6mm NUT.  

6mm 

NUT

SPIDER 

CLAMP

Stainless 

washer

Black plastic 

spacer

35mm dia hole

Sink

O-RING

SINK TOP

Fit the O-ring to the underside of the AIO tap 

then pass all hoses through the 50mm hole. 

Chiller 

connection 

BLUE

From 

Mixer OUT

 to Tap - Vented version only

Boiler 

connection 

RED

Blue ring on 

RHS mains IN to

       

Mixer IN

White ring

on LHS to 

Mains in

Tap

O ring Base

Clear tube to Vent

 * Tap options supplied are dependant 

upon configuration purchased.

• 

The Command-Centre

TM

 must be mounted in upright positions, with base mounted 

horizontally, as shown overleaf.  

IMPORTANT!

  

Do not proceed with the installation if these requirements are not met.

Prior to installation, ensure that the following have been 

provided at the installation site.

• 

Sufficient space in the cupboard to install the Command-Centre

TM

 and it’s ancillary 

components. Refer to the Technical specification of the Installation instructions for 

dimensions. 

• 

A potable water supply connection with min. / max. working pressures of: (refer 

to the Technical specification of the Installation instructions for specific model 

information). 

• 

An isolating valve inside the cupboard within reach of the flexible braided hose and 

positioned so that the connection point and the stop cock will not be obstructed 

when the Command-Centre

TM

 and it’s ancillary components are installed.

• 

For Zip HydroTap

®

G4, a single 220-240V AC, 13A socket is required.

• 

The Command-Centre

TM

 must be installed in accordance with IEE regulations, see 

Technical specifications in the Installation instructions, for power ratings.  

Note

 

Check the cable lengths and outlet positions before proceeding and ensure that the 

tap location will allow the tap spout to drain into the sink. 

 Step 1- 

Prepare and install the taps. Refer to 803341UK Tap installation instructions  

(for Arc / Cube also refer to the tube kit assembly instructions) supplied with the tap.

.

Hole positioning 

Position the tap such that it dispenses 

into the sink bowl with ample clearance for a cup or tea pot. 

Alternatively, the tap could be mounted away from the sink using 

a Zip Font, available as an accessory. See Major components 

and accessories, in the Installation instructions.

Apply a light smearing of silicon sealant on the 

underside of the spacer to ensure a watertight fit.

HydroTap

®

G4 Classic & Elite tap installation

All thread

 rod

Stainless 

steel  

washer

Spider 

clamp

6mm nut

Black 

plastic 

spacer

Note

 Feed each of the three tubes and USB cable evenly in 

between the legs of the spider clamp during installation. 

Fit the 

stainless  steel           

washer, spider 

clamp, and  

6mm nut.  

6mm 

nut

Spider 

clamp

Stainless steel 

washer

Black plastic 

spacer

Ø

35mm hole

HydroTap

®

G4 Classic & Elite taps 

Cut a 

Ø35mm hole in the worktop / sink.

Note 

VENTILATION IS ESSENTIAL

 

Read ‘Step 2’ ‘Ventilation’ before you start.

HydroTap

®

 G4 Classic

116

Tap

Recommended dispensing 

distance (mm)

Elite

116

HydroTap

®

 Classic

116

HydroTap

®

 Arc/Cube

171 (-174 extended)

Tap installation special tool requirements

For the HydroTap

®

G4

• 

35mm diameter sheet metal hole punch for sinks (not supplied).

• 

35mm diameter hole saw for worktops (not supplied).

• 

Nut runner tube spanner for fixing the tap assembly.

Hole positioning

 

Position the tap such that it dispenses into the 

sink bowl with ample clearance for a cup or 

tea pot. Alternatively, the tap could be mounted 

away from the sink using a Zip Font, available 

as an accessory. (See Major components and 

accessories, Command-Centre

TM 

Installation 

instructions).

Tap positioning

Alternative arrangement

For high use applications where the 

cupboard space temperature is near 

35

0

C or higher, the vent kit supplied 

can be used to provide further 

ventilation by convection.

Note 

The vent kit has to be 

installed in a way that allows air 

to be drawn in from the bottom of 

the cupboard and expelled through 

the top of the cupboard. The outlet 

vent should be towards the top of 

the door (position 

A1

) or side of the 

cupboard (position 

A2

).  

(Where possible air inlet vent 

and the air outlet vent should be 

positioned at opposite ends of the 

same cupboard space). 

Ventilation for all models

 

• 

The clearance envelope dimensions stated in the specification sheets and installation 

instructions must be observed.

• 

Adequate ventilation must be provided to ensure that the cupboard space 

temperature does not exceed 35

0

C.

Preferred arrangements

4mm door buffers (at the four corners of each door) supplied with the Command-Centre

TM 

should be used to provide adequate ventilation in normal usage, see illustration below.

Door buffer

A1

A2

B

Vent cut-out details

A1 or A2  Air outlet vent 

B  Air inlet vent

 

Note 

Flat outlet vent detail 

shown, louvred 

outlet vent also 

supplied.

Reviews: