background image

Hydro Tap Installation and Operating Instructions - 89026UK - June 2009                                                Page 1 of 24

Domestic HydroTap

Filtered boiling and chilled drinking water for kitchens.

®

Installation and Operating Instructions

This Installation Instruction covers the following Domestic HydroTap models

Domestic models:

30009UK  - DOMHB1

:   HydroTap Boiling Only, Unfiltered

37697UK  - DOMBA1

:   HydroTap Boiling & Ambient

437677UK- DOMBC1

:   HydroTap Domestic Compact Boiling & Chilled

HydroTap

 with disabled lever kit

HydroTap

Summary of Contents for HydroTap 30009UK

Page 1: ...ater for kitchens Installation and Operating Instructions This Installation Instruction covers the following Domestic HydroTap models Domestic models 30009UK DOMHB1 HydroTap Boiling Only Unfiltered 37...

Page 2: ...rd supporting the appliance is adequate for the total weight of the appliance when full of water Before commissioning 1 Check the unit has been secured correctly 2 Check all plumbing fittings have bee...

Page 3: ...ting and commissioning 10 15 Pull out Font Template pages 11 12 13 14 Step F Temp and Set Point adjustment 15 Font Installation procedure 16 Operating the Tap 17 Child safety lock 18 Setting the Energ...

Page 4: ...ake the system through a calibration process which causes the unit to over boil for a period of 45 90 secs This is normal operation once this mode is completed the system reverts back to normal operat...

Page 5: ...ost Protection If this appliance is located where the ambient air temperature could fall below 5 C when the heater is not in use do not turn off the appliance electrically This safeguard does not offe...

Page 6: ...for timber bench tops not supplied Nut runner tube spanner supplied for fixing tap assembly When installing a Font unit For Font installation a 108mm diameter sheet metal or hole saw to suit surface b...

Page 7: ...A power supply of 220 240 Volt AC for connection to the heater via a 13 amp fused spur The power outlet socket must be positioned within 1 8 metres of the under sink appliance so the plug is made acc...

Page 8: ...dersink unit SPECIAL NOTE The HydroTap undersink units are heavy take note of the weights listed in the table on page 4 If you think you cannot lift the unit safely get help and avoid possible injury...

Page 9: ...and trim the blue tube and connect it to the chilled water outlet located on the top rear left hand side of the undersink unit Use spring clamps provided Measure and trim the red marked tube and conn...

Page 10: ...for a short stabilisation period Once stabilised the element will cycle On bring the water to boiling point and hold it there for a short period Calibration The unit now carries out a self calibration...

Page 11: ...Hydro Tap Installation and Operating Instructions 89026UK June 2009 Page 11 of 24...

Page 12: ......

Page 13: ......

Page 14: ...Page 14 of 24 Hydro Tap Installation and Operating Instructions 89026UK June 2009...

Page 15: ...al not the set temperatures To revert back to the Normal Operation screen press the adjust buttons together again until screen changes Press the Menu plus button once to enter the Hot Temperature Adju...

Page 16: ...base is flush with the bench top NOTE The fixing nut above the drain elbow can be loosened to correctly position the direction of the elbow Ensure when the re positioning is complete the nut is re ti...

Page 17: ...of this document Child Safety Lock boiling chilled models The child safety lock can be activated to prevent boiling water flowing if the hot lever is inadvertently activated To activate first press th...

Page 18: ...s the tap to operate in a no touch mode Water will flow from between 5 and 15 seconds This is user adjustable To reset return the handle to the Off position and repeat the step The lever has to be man...

Page 19: ...t Press either Menu or Menu button until Litres Filtered is displayed Press Adjust once and Reset Counter will be displayed press Adjust button once and Are You Sure will be displayed Press Adjust onc...

Page 20: ...from right to left 3 three times This operation confirms de activation 6 The LCD will show Normal Operation 7 If de activation mode is required de activate by scrolling through the menu and selecting...

Page 21: ...ill from it if tilted 7 Unpack replacement cartridge and write today s date where shown on the label 8 Avoid touching the filter O rings and filter opening as this may cause bacterial contamination of...

Page 22: ...rmation Check filter usage on LCD screen if filter change is displayed follow instructions on page 13 Touch Hot lever and wait for Red LED to stop flashing Wait for Red LED to stop flashing Contact lo...

Page 23: ...e 23 of 24 Typical undersink layout Domestic Compact model 437677UK shown NOTE The pressure limiting valve supplied must be fitted between the external service valve and the appliance Domestic Compact...

Page 24: ...water conditions or to any alteration modification or repair by any party not expressly nominated by Zip No costs are payable by the customer other than any mileage or travelling time charges incurred...

Reviews: