1
2
Box Lock Hole
State Indicator
Thread Hole
3.
Installation
Backup Battery
Control Panel
Air Switch
Panel Box Appearance
Panel Box Inside
Get the Panel off the track
Heat
2.
Components
Thread holes
Screws
4.
LED Indicators and Wire Illustration
Power
Supply
Temper
Switch
After the following installation, fix the panel to the track first, and then install other
components.
Dissipation Hole
Control
Panel
Control
Panel
Panel
Track
Panel
Track
2
2
1
1
3) Install
other
components
2) Fix the box
1) Get through the thread hole
1) Meaning of LED indicators
:
LINK indicator (green):
Constant light indicates TCP/IP communication is normal.
ACT indicator (yellow): Flashing indicates data is transmitting through TCP/IP communication.
EXT RS485 indicator (yellow&green): Flashing indicates it is sending or receiving data through RS485 communication.
PC RS485 indicator (yellow&green): Flashing indicates it is sending or receiving data through RS485 communication.
POWER
indicator (red):
Light always indicates the control panel is power on.
RUN
indicator (green): Flashing indicates that system is working normally.
CARD
indicator (yellow): Flashing indicates card is punched on reader.
2) Recommended use of wires
:
3) The auxiliary input may be connected to infrared body detectors, alarm switches, etc.
4
The auxiliary output may be connected to door bells, alarms, etc.
)
5) State Indicators are connected to the panel box, which is power indicator, run status indicator and communication status indicator.
Interface
Wire Specification
Network cable
Maximum length
Power (A)
18AWG*2PIN
/
1.5M
Wiegand (B)
24AWG*6PIN
(6PIN, 8PIN, 10PIN for different
readers)
CAT-5 or above network cable, one
way DC impedance is less than 100
Ω
/KM
100M
Electric Lock (C)
18AWG*2PIN+24AWG*2PIN,
18AWG*2PIN for lock connection,
24AWG*2PIN
for
door
sensor
connection.
/
50M
Button (D)
24AWG*2PIN
/
100M
EXT485 (E)
20AWG*2PIN+24AWG*2PIN,
20AWG*2PIN
for
reader
power
supply,
24AWG*2PIN
for
RS485
communication
CAT-5 or above network cable, one
way DC impedance less than 100
Ω
/KM. In wire connection, +12V and
GND of power supply need to be
parallel and use double wires.
Share power with control panel: 100M
Use
independence
power
supply
(connect RS485 signal interface only):
1000M
inBIO
26 0
Installation and Connection Guide
Version: 1.3
Date: Jan. 2014
1.
Cautions
Please note the follo wing cautio ns. Mis-operatio n may lead to personal injury or
equipment failu re:
1
)
Do not energize the system before installa tio n is complete; never carry out
installa tio n activ itie s when the system is energized.
2
)
All perip heral devices must be grounded.
3
)
The conduits of wire s under relay must be matched with metaled conduits , other wire s
can use PVC conduits .
4
)
It is stro ngly recommended that the length of exposed part of any connectio n cable
should not be longer than 4 mm. Professional clamping tools may be used to avoid
unintentio nal contact of exposed wire s to avoid short- circ uit or communicatio n failu re.
5
)
It is recommended that card readers and butto ns be installe d at height of 1.4m-1.5m
above ground.
6
)
It is recommended to use the power supply for contro l panel, and external power
supply for each lock.
7
)
The applia nce shall be installe d and wire d in accordance with natio nal electric al
code and by qualifie d personnel only
Descriptio n of normal working state:
Connect the system to the power supply. If the system works properly, the POWER
indicator (red) is lit constantly and the RUN indicator (green) fla shes.
Valve regulated lea d-ac id battery :
Constan t voltage charge voltage reg ulati on
Cycle use : 14.5V ~14.9V (25 )
Initial curren t: less tha n 2.88 A
Stan dby use: 13.6V ~13.8V (25 )
Capacity: 12V, 7.2A h/20 hr,
Battery Type: LC-RA127R2T1
Caution :
Do not charge in a gas tight containe r.
Do not short the battery term ina ls.
Do not inc ine rate
Flush with water at once if contact is made with
elec trolyte (Acid )
Do not attem pt to disasse mble the battery .