USER MANUAL 

TL400B Fingerprint Lock with Voice Guide 
Feature 

Version: 1.1 
Date: Jul. 2017 

 
 
 
 
 

Summary of Contents for TL400B

Page 1: ...1 USER MANUAL TL400B Fingerprint Lock with Voice Guide Feature Version 1 1 Date Jul 2017 ...

Page 2: ...e 2 Basic Function 3 User Introduction 3 Operation and Voice Prompt 4 Initialization 4 Random Password 5 Voice Guide 5 Normal Open 6 User Data Synchronization 6 Low Battery Alarm 6 Volume 7 9V External Battery 7 Emergency Mechanical Key 8 Content ...

Page 3: ... User 12 Delete by User Number 14 Delete Administrator Group 15 Delete Normal User Group 16 Supplemental Register 17 Upload User Data 18 Download User Data 19 Enable Normal Open 20 Volume 21 Quick Start 22 Open the Door With Fingerprint 22 Open the Door With Password 22 Open the Door With Card 22 ...

Page 4: ...anical keys in a safe place 4 To power on the lock four alkaline AA batteries not included are required Non alkaline and rechargeable batteries ARE NOT RECOMMENDED 5 Do not remove batteries when the lock is in working state 6 Please replace the battery soon when the lock prompts the voice of low battery 7 There are 7 seconds stand by time limits for all setting operations without any activity with...

Page 5: ...2 Structure 1 Keypad Area 2 Card Detection Area 3 Fingerprint Sensor 4 Handle 5 Mechanical Key Hole 6 9V battery Interface 7 Battery Area 8 USB Port 9 Reset Button 1 2 3 4 5 6 7 9 8 ...

Page 6: ...n Administrator Fingerprint Menu Operation Open The Door Password ID Card Normal User Fingerprint Open The Door Password ID Card Note 1 The maximum capacity of fingerprint or password or ID card is100 2 The length of password is 6 digits Basic Function ...

Page 7: ...as already registered This fingerprint is already used Password has already registered This password is already used ID Card has already registered This card is already used User Number has already registered This user number is already used Initialization Initializing the lock means all data will be deleted and restored to factory default setting Operation Instruction Press the reset button then ...

Page 8: ...m digits correct password random digits Users may enter any random digits in front of and behind the correct password to create random password to open the door The maximum length of the random password is 32 digits For example If the correct password is 123456 the random password can be 89123456807 1234562363 389123456 etc Voice Guide After access into the menu the lock will prompt voice before a...

Page 9: ...om one lock to other locks it will help users to save time in some repeated registrations Low Battery Alarm When the lock is in low battery status it will trigger the alarm with the sound of short beep and the voice of Battery is low please replace After triggering low battery alarm the lock will be out of battery in approx 200 operations Note Access to operation steps is not allowed in low batter...

Page 10: ...ith individual preference and requirement The default volume level is 3 and the adjustable range is 0 7 9V External Battery 9V external battery is used to open door when the lock is out of battery Note The above battery must be 9V alkaline battery 6LR61 ...

Page 11: ...hen the lock has electronic malfunction Note Keep the mechanical key in a safe place Note AB key system is available for this model if you need this function please contact the sales Insert the key into key hole and rotate 90 then press down the handle to open the door ...

Page 12: ...ice prompt Register administrator enter three digits user number Voice prompt Completed please continue to enter Enter 3 digits user number Voice prompt Enter fingerprint or card or password How To Use Note 1 Place one finger 3 times on fingerprint sensor to register fingerprint 2 The length of password is 6 digits 3 The regular length of user number is 3 digits However it is also correct to enter...

Page 13: ...gistration and go back into previous step Continue to register other identifications on the same user number Keypad backlight fingerprint sensor is power on Voice prompt Verify administrator Start voice guide for the key of 1 to 6 Start voice guide for the key of 1 and 2 Voice prompt Enter three digits user number Voice prompt Completed please continue to enter Enter fingerprint or card or passwor...

Page 14: ...d is 6 digits When verify administrator by password press to end 3 The regular length of user number is 3 digits However it is also correct to enter 1 digit or 2 digits with the end of as the user number For example 001 is equal to 1 or 01 4 Press to cancel registration before the registration is complete ...

Page 15: ...tion and go back into previous step Continue to register other identifications on the same user number Keypad backlight fingerprint sensor is power on Voice prompt Verify administrator Start voice guide for the key of 1 to 6 Start voice guide for the key of 1 and 2 Voice prompt Enter three digits user number Voice prompt Completed please continue to enter Enter fingerprint or card or password Ente...

Page 16: ...d is 6 digits When verify administrator by password press to end 3 The regular length of user number is 3 digits However it is also correct to enter 1 digit or 2 digits with the end of as the user number For example 001 is equal to 1 or 01 4 Press to cancel registration before the registration is complete ...

Page 17: ...voice guide for the key of 1 to 6 Start voice guide for the key of 1 and 2 Voice prompt Enter three digits user number Voice prompt Deleted Enter 3 digits user number again Enter 3 digits user number Voice prompt Enter user number again Note 1 The regular length of user number is 3 digits However it is also correct to enter 1 digit or 2 digits with the end of as the user number For example 001 is ...

Page 18: ...rprint sensor is power on Voice prompt Verify administrator Start voice guide for the key of 1 to 6 Start voice guide for the key of 1 and 2 Start voice guide for the key of 1 and 2 Voice prompt Wait a moment completed Press to confirm Press 1 to delete administrator group Voice prompt Delete administrator group press the pound key to confirm Note 1 When verify administrator by password press to e...

Page 19: ...gerprint sensor is power on Voice prompt Verify administrator Start voice guide for the key of 1 to 6 Start voice guide for the key of 1 and 2 Start voice guide for the key of 1 and 2 Voice prompt Wait a moment deleted Press to confirm Press 2 to delete normal user group Voice prompt Delete normal user group press the pound key to confirm Note 1 When verify administrator by password press to end 2...

Page 20: ...on the same user number Keypad backlight fingerprint sensor is power on Voice prompt Verify administrator Start voice guide for the key of 1 to 6 Voice prompt Enter three digits user number Voice prompt Enter fingerprint or card or password Enter fingerprint or card or password Voice prompt Completed please continue to enter Note 1 The regular length of user number is 3 digits However it is also c...

Page 21: ...or by fingerprint or card or password Press 4 to upload user data Keypad backlight fingerprint sensor is power on Voice prompt Verify administrator Start voice guide for the key of 1 to 6 Voice prompt Uploading Wait a moment Completed Note 1 Please insert U disk at first before above operations 2 When verify administrator by password press to end ...

Page 22: ...r by fingerprint or card or password Press 5 to download user data Keypad backlight fingerprint sensor is power on Voice prompt Verify administrator Start voice guide for the key of 1 to 6 Voice prompt Downloading Wait a moment Completed Note 1 Please insert U disk at first before above operations 2 When verify administrator by password press to end ...

Page 23: ...int or card or password Press 6 to enable normal open Keypad backlight fingerprint sensor is power on Voice prompt Verify administrator Start voice guide for the key of 1 to 6 Voice prompt Normal Open is enabled Note 1 To disable normal open please use any registered fingerprint card password to unlock the door 2 When verify administrator by password press to end ...

Page 24: ...rd Press 01 to enable volume setting Keypad backlight fingerprint sensor is power on Voice prompt Verify administrator Start voice guide for the key of 1 to 6 Voice prompt Beep Press 1 once decrease 1 volume press 2 once add 1 volume press to confirm Voice prompt Beep Note 1 The volume of the Beep is the current volume 2 When verify administrator by password press to end ...

Page 25: ...oor Touch the keypad to power on the lock Enter password and press to end Press down the handle to open the door Touch the keypad to power on the lock Swipe the registered card on the card area Press down the handle to open the door Note User may enter random password to prevent any person beside you from detecting your password The maximum length of the random password is 32 digits ...

Page 26: ...23 ...