background image

D

ropins

Installation Guide

and Users Manual

Summary of Contents for RT-36

Page 1: ...Dropins Installation Guide and Users Manual ...

Page 2: ...g your appliance you will have easy and accurate access to Technical Support Warranty Service Tracking your support inquiries Tracking your support inquiries WARNING This product can expose you to chemicals including nickel which is known to the State of California to cause cancer For more information go to www P65Warnings ca gov SCAN ME ...

Page 3: ...n elevated experience in the heart of your home With an endless selection of features and finishes our inspiration is your reality ZLINE is fueled by a passion for innovation A relentless pursuit of bringing the highest end luxury designs and professional features into everyone s homes Because we continually strive to improve our products we may change specifications and designs without prior noti...

Page 4: ... fire stations common areas in multi family dwellings nursing homes food service locations and institutional food service locations such as hospitals or correction facilities This warranty is non transferable and will not be extended based on the date of installation The warranty applies only to products installed in the continental United States and the District of Columbia Failure to secure cert...

Page 5: ...al gas supply issues resulting in low gas pressure or other issues 7 Removal or re installation cost 8 Aesthetic damage scratches or natural wear caused by normal use 9 Second hand open box products or products purchased from an unauthorized retailer 10 Service for gas pressure issues related to installation at high altitudes A high altitude pressure regulator must be sourced by the customer NOTE ...

Page 6: ...NSIONS 3 BEFORE INSTALLATION 4 INSTALLATION REQUIREMENTS 6 INSTALLATION 7 POWER RATING ELECTRICAL CONNECTION 8 GAS CONNECTION 9 GAS CONVERSION PROCEDURE 12 INSTALLATION CHECKLIST 16 FINAL PREPARATION 16 ROOM VENTILATION 17 COOKTOP COOKING 17 MAINTAINING YOUR RANGE 20 TROUBLESHOOTING 21 ...

Page 7: ...nsumer who should retain for local inspectors use and for future reference The plug should always be accessible Installation must conform with local codes or in the absence of codes the National Fuel Gas Code NSIZ223 1 NFPA54 Electrical installation must be in accordance with the National electrical code ANSI NPA70 latest edition and or local codes In Massachusetts Installation must be performed b...

Page 8: ...oning and overheating of the oven NEVER cover any slots holes or passages in the oven bottom or cover an entire rack with materials such as aluminum foil Doing so blocks air flow through the oven and may cause carbon monoxide poisoning Aluminum foil linings may also trap heat causing a fire hazard WHAT TO DO IF YOU SMELL GAS DO NOT light any appliance DO NOT touch any electrical switch DO NOT use ...

Page 9: ...e warranty WARRANTY AND SERVICE All range products carry a one year parts warranty and includes service if required Service on all products shall be carried out by industry professionals only For warranty service please call customer service REPLACEMENT PARTS Only authorized replacement parts may be used in performing service on this appliance Replacement parts are available from ZLINE Call 1 614 ...

Page 10: ...ng this appliance to the gas supply line DO NOT bend or damage the flexible connector when moving the appliance This appliance must be used with the pressure regulator provided The regulator must be properly installed in order to be accessible when the appliance is installed in its final location The pressure regulator must be set for the type of gas to be used The pressure regulator has 34 female...

Page 11: ...nce This operating pressure is 4 w c 1 00kPa for Natural gas and 1 1 w c 2 75 kPa for LP gas Gas cooktop requires 1 6 side wall spacing above the counter height for proper combustion Please review specific model installation instructions for required dimensions 30 inches between the cooktop and bottom of the cabinet above 0 25 inches for sides below countertop height NOTE Please consult your local...

Page 12: ...ze A B C D H1 H2 30 30 21 28 3 8 18 7 8 2 13 16 5 8 36 36 21 34 3 8 18 7 8 2 13 16 5 8 Clearances A B D E F 30 6 min 6 min 3 1 2 min 30 3 1 2 min 36 6 min 6 min 3 1 2 min 36 3 1 2 min L1 L2 L3 Cut out size Suggestion Min Max Suggestion Min Max Min 30 29 28 9 16 29 3 8 19 1 2 19 1 8 20 3 8 2 1 2 36 35 34 9 16 35 3 8 19 1 2 19 1 8 20 3 8 2 1 2 INSTALLATION ...

Page 13: ...ructions in Fig 1 1 Lay out the protective sealing strips along the edges of the opening in the bench top and carefully overlap the strip end See Fig 1 2 Insert the dropin into the bench top opening With a screwdriver assemble the brackets A to the hotplate bottom by means of the screws B See Fig 2 3 Slide the hooks into position and secure them with the screws 4 Trim the part of the sealing strip...

Page 14: ...c 12A Max ELECTRICAL GROUNDING Our gas range is equipped with a three prong plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle Do not cut or remove the prong from this plug WARNING Disconnect electrical power at the circuit breaker box or fuse box before installing the appliance Provide appropriate ground for the appliance Use copper co...

Page 15: ... of the dealer and the owner of the range to perform the appropriate gas conversion following the directions of the manufacturer The gas conversion procedure is described in this manual and in the package containing the conversion nozzles shipped with every range Please provide the service person with this manual before work is started on the range Leak testing of the appliance shall be conducted ...

Page 16: ... AGA design certified commercial flexible connector of at least 1 3cm IF NPT with a suitable strain relief in compliance with ANSI Z21 41 and Z21 69 standards In Massachusetts The unit must be installed with a 36 3 foot long flexible gas connector In Canada Use CAN 1 6 10 88 metal connectors for gas appliances and CAN 1 6 9 M79 quick disconnect device for use with gas fuel PRESSURE TEST POINT STOP...

Page 17: ... c P L P Propane 10 0 W c P Incoming line pressure upstream from the regulator must be 1 W C P higher than the manifold pressure in order to check the regulator The regulator used on this range can withstand a maximum input pressure of PSI 13 8 W C or 3 5kPa If the line pressure exceeds that amount a step down regulator is required The appliance its individual shut off valve and the pressure regul...

Page 18: ...f all steps are not completed Before performing the gas conversion locate the package containing the replacement nozzles which has a number indicating its flow diameter printed on the body Consult the table below for matching nozzles to burners Save the nozzles removed from the range for future use LPG Liquid Propane Gas NG Natural Gas INSTALLATION Gas Connection Propane Conversion Video SCAN ME ...

Page 19: ...e and instruction booklet To convert the regulator for use with other liquid propane LP gas 1 Unscrew the front cap of the regulator as seen below Inside the cap is a screw By hand remove the screw to reveal a spring Reapply the screw to the cap with the spring revealed 2 With the spring sticking out of the cap reapply back to the regulator Any issues related to improper propane conversion are NOT...

Page 20: ...a 7 mm socket wrench 2 Replace nozzles using the conversion set supplied with the range Each nozzle has a number indicating its flow diameter printed on the body Consult the table on page 16 for matching nozzles to burners INSTALLATION NG Natural Gas LPG Liquid Propane Gas NG LPG 9 32 9 32 Step1 Step 2 Step 3 Step 4 Step 5 Gas Conversion Procedure ...

Page 21: ...e MINIMUM position The high flame setting cannot be adjusted to be lower If the height is too high revisit the conversion set up A step may have been missed Flame Adjustment WIRING DIAGRAM DW7714 18 DW7713 24 18 24 Panel Ready Dishwasher FLAME ADJUSTMENT Germania RA series RG series 2 0 x 50 mm 2 0 x 50 mm If the customer flame control valve looks like this left then they will not be able t flame ...

Page 22: ...imum setting for all burners been adjusted 12 Have the cooktop flames been adjusted to customer preference 13 Are the oven burners elements installed properly and functioning FINAL PREPARATION All stainless steel body parts should be wiped with hot soapy water and with a stainless steel cleanser If build up occurs do not use steel wool abrasive cloths cleaners or powders If it is necessary to scra...

Page 23: ...efore maintenance and cleaning disconnect the appliance and allow cooling down For reasons of hygiene and safety this appliance must always be kept clean Take care when using cleaning products in spray form never direct the spray onto the electrical wiring thermostat and bulb Ensure that air can circulate around the gas appliance Poor ventilation can result in lack of oxygen and extinguish the fla...

Page 24: ...rn the control knob counter clockwise to the MAXIMUM position light the flame with a kitchen lighter or with a match USING THE BURNERS CORRECTLY 1 Always check that the burner caps are properly installed before operation 2 Verify that the flame of the worktop burners is completely blue and with a regular aspect as shown below 3 Never let flames wrap around cookware DO NOT ignite the burners if the...

Page 25: ... size by turning the knob in anti clockwise direction Should the burner fail to light up turn the knob to its original position and try again Your burner flame should be blue in color NOTE When igniting a burner all burners will spark but only the burner s knob you are using will ignite the flame NOTE When first used the gas burner will not ignite immediately Time is required for the LPG to fully ...

Page 26: ...m the burner heads and wash them in a warm soap and water solution Dry thoroughly before using them again Before reinstalling them on the burner head check that the gas flow holes are not clogged with food residues or cleaning products Cleaning Porcelain Porcelain parts should be cleaned frequently with warm soap and water solution applied with a soft sponge or wipe Never use abrasive powders or l...

Page 27: ... flame is large distorted or yellow The air quality of the room is affecting the flame color Ensure that there are no candles cleaning products etc in the room Low flames and longer cooking times The propane conversion procedure may not have been performed properly Check that all orifices are correctly placed If not contact your installer Brass burners changed color Brass burners naturally oxidize...

Page 28: ...Installation Guide and User Manual 1 614 777 5004 2 0 0 www zlinekitchen com contact zlinekitchen com ...