background image

H0638700_REVC - 2018/11

More documents on:

www.zodiac.com

Z400 iQ

Instructions for installation and use

 - 

English

Heat pump

Translation of the original instructions in French

EN

Summary of Contents for Z400 iQ

Page 1: ...H0638700_REVC 2018 11 More documents on www zodiac com Z400 iQ Instructions for installation and use English Heat pump Translation of the original instructions in French EN ...

Page 2: ......

Page 3: ...hould be referred to a qualified professional Incorrect installation and or use may cause serious damage to property or serious injuries possibly causing death All equipment even postage and packing paid travels at the risks and perils of the recipient The latter shall issue reserves in writing on the carrier s delivery slip if damage is detected caused during transport confirmation to be sent to ...

Page 4: ... from the power supply circuit Do not disconnect and reconnect the appliance to the power supply when in operation Do not pull on the power cord to disconnect it from the power supply Ifthepowercordisdamaged itmustbereplacedbythemanufacturer itstechnician or a qualified person to guarantee safety Do not perform maintenance or servicing operations on the appliance with wet hands or if the appliance...

Page 5: ...ure sensors Some elements such as the compressor and piping may reach temperatures in excess of 100 C and high pressures with the consequent risk of severe burns Troubleshooting All soldering work must be carried out by a someone qualified to do so Replacement pipes must always be made of copper in compliance with standard NF EN 12735 1 Leak detection pressure test never use oxygen or dry air risk...

Page 6: ...re handling the appliance it is vital that you read this installation and user manual as well as the Warranty booklet delivered with the appliance Failure to do so may result in material damage or serious or fatal injury and will void the warranty Keep and pass on these documents for later viewing throughout the appliance s service life The distribution or modification of this document in any way ...

Page 7: ... marking may contain sharp edges which can cause injury In order to prevent any injury wear protective gloves during servicing operations which may involve contact with the evaporator Only an outdoor installation is possible provide free space around the appliance according to diagram 1 2 I Hydraulic connections Place the appliance on its anti vibration blocks integrated under its base height adju...

Page 8: ...ards a window Do not tilt it towards your neighbours Install it in an open space sound waves are reflected on surfaces Install an acoustic screen around the heat pump respecting the distances see diagram 1 2 I Hydraulic connections Install 50 cm of flexible PVC pipe at the heat pump water inlet and outlet to absorb vibrations Increase the filtration time by 50 and activate silence mode The heat pu...

Page 9: ...t valve by pass valve water outlet valve water inlet adjustment valve optional water outlet adjustment valve optional water treatment minimum distance To evacuate the condensates fit a Ø18 pipe on the grooved elbow mounted under the appliance base The elbow can be oriented at an angle of 280 beneath the appliance Condensate drainage elbow view of the device from below Tip condensate drainage Cauti...

Page 10: ... supply with a TT or TN S neutral regime Electrical protection by circuit breaker D curve rating to be defined according to the table 5 2 I Technical specifications with a suitable dedicated differential protection device circuit breaker or switch Additional protection may be required during installation to guarantee the II overvoltage category The power supply must correspond to the voltage indic...

Page 11: ...nection terminal board for single phase power Connection terminal board for three phase power 1 4 1 Wiring on a spring cage terminal block Pull the lever to the maximum then connect the cable s see picture Return the lever to its original position see image EN ...

Page 12: ... risk of interference using a collar inside the appliance just after the glands 1 5 1 Heating priority option This function helps to keep the water temperature constant by checking the water temperature at regular time intervals minimum 5 minute cycle every 120 minutes by filtration pump control The filtration is kept operating if the pool temperature is below the temperature requested For the con...

Page 13: ...emperature rise set the water circulation to continuous operation 24 24 To maintain the temperature throughout the season run automatic circulation for at least 12 hours day the longer this time the longer the heat pump will have enough operating range to heat up Cover the pool with a sheet bubble canopy canvas etc to prevent heat loss The heat pump will be even more efficient if it operates durin...

Page 14: ...mperature Air temperature out of operating range Air temperature in the operating range Cold mode Cold mode activated Cold mode desactivated Silence mode Silence mode activated Silence mode desactivated 2 2 3 Description of the LEDs showing the appliance status LED Appliance status Meaning Steady green OK Temperature reached or operation in hot mode Steady blue OK Operation in cold mode Steady red...

Page 15: ...ltration circuit will bleed out If valves D and E are not present open valve A wide and close valve C by half Connect the power supply to the heat pump The heat pump is on standby Press for 2 seconds software version vary depending on the appliances is displayed for 4 seconds the last water temperature measured is then displayed This value varies depending on the last temperature recorded during t...

Page 16: ...pump The appliance will operate for a longer period of time with less power however with a lower noise level There are 2 ways to activate the Silence mode 1st method Press and release the symbol will light up 2nd method Press and hold Press or to display Press and release the symbol will light up The home screen automatically reappears after 60 seconds of inactivity on the keypad or by pressing an...

Page 17: ... micro cover provided on the heat pump 3 2 I Maintenance Before performing any maintenance operation on the appliance you must cut the electricity supply as there is a risk of electric shock which may cause material damage serious injury or even death It is recommended that the appliance undergo general servicing at least on a yearly basis to ensure proper operation maintain performance levels and...

Page 18: ...oo low below 12 C The appliance is smoking The machine has come to the end of the defrost cycle water has changed to gaseous state and passes through the grid If your heat pump is not in its defrost cycle this is not normal Switch off and disconnect the heat pump immediately and contact your retailer The appliance is not working If there is no display check the supply voltage and the F2 fuse When ...

Page 19: ...g red LED press Cooling circuit high pressure fault Exchanger clogged with dirt Clean the water exchanger Steady red LED automatic Flashing red LED press Insufficient water flow Increase flow using the by pass check that the pool filter is not clogged Air and water emulsion has passed into the appliance Check the pool s hydraulic circuit Flow switch is blocked Check the flow switch Compressor disc...

Page 20: ... the connectors on the link cable between the boards Steady red LED automatic Flashing red LED press Board power supply fault Check the boards power supply Faulty boards Replace the boards 4 3 I Lighting of LEDs on the printed circuit board LED1 LED2 LED3 LED4 LED5 No errors Appliance switched off No errors Appliance in operation Error 01 Error 02 Error 03 Error 04 Error 05 Error 06 Error 07 Error...

Page 21: ...19 4 4 I Wiring diagrams 4 4 1 Z400 iQ MD4 MD5 MD7 EN ...

Page 22: ...20 4 4 2 Z400 iQ MD8 MD9 ...

Page 23: ...21 4 4 3 Z400 iQ TD7 TD8 TD9 EN ...

Page 24: ...T3 Defrost sensor ST4 Refrigerant liquid temperature sensor ST5 Compressor discharge temperature LP Low pressure switch HP High pressure switch REV VALV Reversion valve EXP VALVE Expansion valve M1 Fan motor M2 Compressor motor HEATER Anti frost heater FAN HEATER Air conveyor resistance TP1 Terminal plate TP2 Terminal plate F1 F2 Fuse V1 V2 Varistor V4 Gas discharge tube RED Red BLK Black VLT Viol...

Page 25: ...ristics 5 1 I Description In the appliance s box A Z400 iQ B Winterizing cap x2 C Ø50 connector to be glued x2 D Winterizing cover Heating priority E PAC NET cleaning product supplied available as an accessory EN ...

Page 26: ... 65 66 68 70 70 70 70 Silence 61 63 63 66 70 70 70 70 Maximum impedance value Zmax ohm 0 056 0 040 Under validation Approximate weight kg 70 71 90 94 105 105 110 110 Values provided for information purposes for a maximum length of 20 metres calculation base NFC 15 100 must be checked and adapted to the installation conditions and standards of the installation country Maximum operating pressure of ...

Page 27: ......

Page 28: ...023 49180 St Barthélémy d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Modèle appareil Appliance model Numéro de série Serial number Pour plus d informations enregistrement produit et support client For more information product registration and customer support www zodiac com ...

Reviews: