INSTALLATION INSTRUCTIONS

RECOMMENDED MODELS

P/N 151797

Notice to installing contractor:  Instructions must remain with installation.

FM2676

0117

Supersedes

0816

PREINSTALLATION CHECKLIST - ALL INSTALLATIONS

DATE INSTALLED:

MODEL NUMBER:

1.   Inspect your pump. Occasionally, products are damaged during shipment.  If the unit is damaged, contact your dealer before using. DO NOT remove the test plugs in the cover nor the motor housing.

2.   Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained for future reference.

EFFLUENT*/SUMP/DEWATERING SEWAGE

49 / 53 / 57 Series, 98 Series

264 Series

137 Series, 151 / 152 / 153 Series

266 / 267 Series

CAUTION

SEE BELOW FOR

LIST OF CAUTIONS

SEE BELOW FOR

LIST OF WARNINGS

 1.   Make certain that the receptacle is within the reach  of the pump’s power supply cord.  DO NOT 

USE AN EXTENSION CORD. Extension cords that are too long or too light do not deliver sufficient 

voltage to the pump motor, and they could present a safety hazard if the insulation were to become 

damaged or the connection end were to fall into a wet or damp area.

  2.   Make sure the pump electrical supply circuit is equipped with fuses or circuit breakers of 

proper capacity.  A separate branch circuit is recommended, sized according to the “National 

Electrical Code” for the current shown on the pump nameplate.

  3.  Testing for ground.   As a safety measure, each electrical outlet should be checked for ground 

using an Underwriters Laboratory Listed circuit analyzer which will indicate if the power, neutral and 

ground wires are correctly connected to your outlet.  If they are not, call a qualified, licensed electrician.

  4.   For Added Safety.  Pumping and other equipment with a 3-prong grounded plug must be connected 

to a 3-prong grounded receptacle. For added safety the receptacle may be protected with a ground-

fault circuit interrupter. When a pump needs to be connected in a watertight junction box, the plug 

can be removed and spliced to the supply cable with proper grounding. For added safety this circuit 

may be protected by a ground-fault circuit interrupter. The complete installation must comply with 

the National Electrical Code and all applicable local codes and ordinances.

  5.  FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE 

HANDLING.  Single phase pumps are supplied with a 3-prong grounded plug to help protect you 

against the possibility of electrical shock.  DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE 

THE GROUND PIN.  The 3-prong plug must be inserted into a mating 3-prong grounded receptacle.  

If the installation does not have such a receptacle, it must be changed to the proper type, wired 

and grounded in accordance with the National Electrical Code and all applicable local codes and 

ordinances.  Three phase pumps require motor starting devices with motor overload protection. See 

FM0486 for duplex installations.

 6. The tank is to be vented in accordance with local plumbing code.  Pumps must be installed in 

accordance with the National Electrical Code and all applicable local codes and ordinances.  Pumps 

are not to be installed in locations classified as hazardous in accordance with National Electrical 

Code, ANSI/NFPA 70.

  7.  Risk of electrical shock. Do not remove power supply cord and strain relief or connect conduit 

directly to the pump.

 8.  Installation and servicing of electrical circuits and hardware should be performed by a qualified 

licensed electrician.

 9.  Pump installation and servicing  should be performed by a qualified person.

 10.  Risk of electrical shock - These pumps have not been investigated for use in swimming pool and 

marine areas.

 11.  According to the state of California (Prop 65), this product contains chemicals known to the state 

of California to cause cancer and birth defects or other reproductive harm.

  1.  Check to be sure your power source is capable of handling the voltage requirements of the motor, 

as indicated on the pump name plate.

  2.  The installation of automatic pumps with variable level float switches or nonautomatic pumps using 

auxiliary variable level float switches is the responsibility of the installing party and care should be 

taken that the tethered float  switch will not hang up on the pump apparatus or pit peculiarities and 

is secured so that the pump will shut off.  It is recommended to use rigid piping and fittings and the 

pit be 18" (46 cm) or larger in diameter.

  3.  Information - vent hole purpose.  It is necessary that all submersible sump, effluent, and sewage 

pumps capable of handling various sizes of solid waste be of the bottom intake design to reduce 

clogging and seal failures.  If a check valve is incorporated in the installation, a vent hole (approx. 

3/16" [5 mm]) must be drilled in the discharge pipe below the check valve and pit cover to purge 

the unit of trapped air. Trapped air is caused by agitation and/or a dry basin.  Vent hole should be 

checked periodically for clogging.  The 53 / 57, and 98 Series pumps have a vent located in the pump 

housing opposite the float, adjacent to a housing lug, but an additional vent hole is recommended.  

The vent hole on a High Head application may cause too much turbulence. You may not want to 

drill one. If you choose not to drill a vent hole, be sure the pump case and impeller is covered with 

liquid before connecting the pipe to the check valve and no inlet  carries air to the pump intake. 

NOTE: THE HOLE MUST ALSO BE BELOW THE BASIN COVER AND CLEANED PERIODICALLY. 

Water stream will be visible from this hole during pump run periods.

 4.  Pump should be checked frequently for debris and/or buildup which may interfere with the float “on” 

or “off” position. Repair and service should be performed by Zoeller Pump Company Authorized 

Service and Warranty Center.

  5.  Dewatering and effluent sump pumps are not designed for use in pits handling raw sewage.
  6.  Maximum operating temperature for standard model pumps must not exceed 130°F (54°C).  
  7.  Pump models 266, 267, and 137 must be operated in an upright position. Do not attempt to start 

pump when tilted or laying on its side.

  8.  Do not operate a pump in an application where the Total Dynamic Head is less than the minimum 

Total Dynamic Head listed on the Pump Performance Curves.

REFER TO WARRANTY ON PAGE 2.

NOTE: Pumps with the “UL” mark and pumps with the “US” mark are tested to UL Standard UL778. 

CSA Certified pumps are certified to CSA Standard C22.2 No. 108.

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO:

  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:

  3649 Cane Run Road  • Louisville, KY  40211-1961

TEL:

 (502) 778-2731 • 1 (800) 928-PUMP • 

FAX:

 (502) 774-3624

Visit our web site:

zoellerpumps.com

* Effluent systems should specify that pumps should not handle solids exceeding 3/4” (19.1 mm) in order to prevent large solids from entering leeching fields, mound systems, 

etc.  (Model 49 Series has 3/8” [9.5 mm] solids capability.  50, 90, and 151 Series have ½” [12.7 mm], 130 Series has 5/8” [15.9 mm], 152 and 153 models have 3/4” [19.1 mm].)  

Where code permits, sewage pumps can be used for effluent systems.  Nonautomatic pumps with external-level controls are recommended for septic tank effluent applications.

NOTICE: VENT HOLE FOR

CHECK VALVE

SEE #3 IN CAUTION SECTION

BELOW AND #4 ON PAGE 3

© Copyright 2017 Zoeller

®

 Co. All rights reserved.

Register your 

Zoeller Pump Company 

Product on our website:

http://reg.zoellerpumps.com/

Summary of Contents for 57 Series

Page 1: ...n investigated for use in swimming pool and marine areas 11 According to the state of California Prop 65 this product contains chemicals known to the state of California to cause cancer and birth defe...

Page 2: ...Authorized Service and Warranty Centers Go to www zoellerpumps com servicestations to find the Authorized Service Center in your area SERVICE CHECKLIST EASY DO S DON T S FOR INSTALLING A SUMP PUMP 1 D...

Page 3: ...ee 3 under Caution on front page Water stream will be visible from this hole during pump run periods 5 Securely tape or clamp power cord to discharge pipe clear of the float mechanism s 6 Use full siz...

Page 4: ...equire motor starting devices with motor overloadprotection SeeFM0486forduplexinstallations Pumps mustbe installed in accordance withthe National Electrical Code and all applicable local codes and ord...

Page 5: ...usar tuber a y empalmes r gidos y que el foso tenga 45 cm 18 pulg o m s de di metro 3 Informaci n Objetivo del agujero de ventilaci n Es necesario que todas las bombas sumer gibles de sumidero efluen...

Page 6: ...i n en la tuber a de descarga JAM S use una tuber a de descarga de menor tama o que la descarga de la bomba 7 JAM S use una bomba de sumidero como una bomba excavadora o para zanjas ni para bombear ag...

Page 7: ...E M S ABAJO 12 Los sellos herm ticos contra gases son necesarios en todas las instalaciones de aguas cloacales a fin de contener los gases y olores 13 Ventile los gases y olores a la atm sfera a trav...

Page 8: ...l cable de alimentaci n el ctrica ni el dispositivo de alivio de tensi n y no conecte un conductor directamente a la bomba ADVERTENCIA La instalaci n y verificaci n de los circuitos el ctricos y del e...

Page 9: ...de l appareil 2 L installateur est responsable de l installation des pompes automatiques avec des interrupteurs niveau variable ou des pompes non automatiques utilisant des interrupteurs auxiliaires n...

Page 10: ...ARANTIE LIMIT E Le fabricant garantit l acheteur et au propri taire ult rieur pendant la p riode de garantie tout produit neuf contre tout vice de mat riel et de main d uvre en utilisation normale et...

Page 11: ...ensions 7 Le puits doit tre conforme tous les r glements applicables 8 Avant la mise en service la pompe doit tre de niveau et le m canisme du flotteur ne doit pas toucher les bords du puits 9 Apr s l...

Page 12: ...Plage de pompage 5 10 15 20 22 9 13 5 18 22 24 127 mm 5 po min 559 mm 22 po max SK305 Interrupteur 20 amps mod les WD et WH min max 011835 Instructions de branchement triphas AVERTISSEMENT POUR DES RA...

Reviews: