background image

1

 

 

 

 

 

MF971R     

Quick  Start  Guide     

 

 

 

 

 

 

 

 

 

ZTE CORPORATION   
NO. 55, Hi-tech Road South, Shenzhen, P.R.China   
Postcode: 518057 

Summary of Contents for MF971R

Page 1: ...1 MF971R Quick Start Guide ZTE CORPORATION NO 55 Hi tech Road South Shenzhen P R China Postcode 518057 ...

Page 2: ...2 Getting to Know Your Device Appearance The following figure is for your reference only ...

Page 3: ...onds to power on off your device Press and hold for about 8 seconds to restart your device 2 WPS key Press and hold for 1 5 seconds to activate the WPS function 3 Indicator light 4 Charging micro USB jack 5 micro SIM card slot cover and reset hole ...

Page 4: ...ery Green blinking The battery is being charged Green solid The battery level is middle or high Light off Your device is powered off and not being charged Wi Fi Blue solid Wi Fi is active Blue blinking WPS is active Light off Wi Fi is off SMS Blue solid You have unread messages Blue blinking You have new messages or the message storage is full ...

Page 5: ...registered to the mobile network There is no micro SIM card inserted There is no network service available Green solid The device is registered to the 2G 3G mobile network Green blinking The device is connected to the 2G 3G mobile network and data is being transferred Blue solid The device is registered to the 4G LTE network ...

Page 6: ...work and data is being transferred Getting to Know Your Device Connection Scenarios The device allows multiple clients to surf on the Internet at the same time The following figure is for your reference only A micro SIM card can be used to access the Internet ...

Page 7: ...7 ...

Page 8: ... rudely because it is connected with the device 2 Install a micro SIM card to the micro SIM card slot WARNING To avoid damage to the device do not use any other kind of SIM cards or any non standard micro SIM card cut from a SIM card You can get a standard micro SIM card from your service provider ...

Page 9: ...9 3 Close the micro SIM card slot cover ...

Page 10: ...omputer to obtain an IP address automatically 3 Select the Wi Fi name SSID of your device and click Connect 4 Enter the Wi Fi password if necessary and click OK NOTE Refer to the chapter Getting to Know the Wi Fi SSID and Password to get the default Wi Fi SSID and password 5 Wait until the client device is connected to your device successfully Using a USB Cable 1 Connect a computer to your device ...

Page 11: ...11 3 Wait until the computer is connected to your device successfully ...

Page 12: ...12 Getting to Know the Wi Fi SSID and Password You can view the label on the device to get the default Wi Fi SSID and password ...

Page 13: ...etween your device and the client device is correct 2 Launch the Internet browser and enter http 192 168 0 1 or http ufi ztedevice com in the address bar 3 Enter the password to log in to the 4G Mobile Hotspot configuration page NOTE View the label on the device to get the default password ...

Page 14: ...14 Changing the Wi Fi SSID or Password 1 Log in to the 4G Mobile Hotspot configuration page 2 Select Wi Fi Settings 3 Change the Network Name SSID or the Password in the Main SSID area 4 Click Apply ...

Page 15: ...nnected to the Internet and you can surf on the Internet through the client Manual 1 Log in to the 4G Mobile Hotspot configuration page 2 Select network Settings Connection Mode Manual and then click Apply 3 Click to return to the home page and click or NOTES To change the current connection setting please disconnect from the Internet first To modify the parameters of your device log in to the 4G ...

Page 16: ...nection 1 Right click Network and select Properties 2 Select Change adapter settings 3 Right click Wireless Network Connection and select Properties 4 Select Internet Protocol Version 4 TCP IPv4 and click Properties 5 Select Obtain an IP address automatically and Obtain DNS server address automatically and click OK ...

Page 17: ...ice at places such as oil warehouses or chemical factories where there are explosive gases or explosive products being processed Power off the device if necessary Do not use electronic transmission devices in aircraft at petrol stations or in hospitals Observe and obey all warning signs and power off the device in these conditions Do not touch the inner antenna area unless necessary Otherwise the ...

Page 18: ...ice Do not use it until it becomes dry Handle the device carefully Do not drop bend or strike it Otherwise the device may be damaged Only qualified personnel can dismantle and repair the device The humidity between 5 and 95 is recommended Do not connect the charger while using the device for a long period Failing to do so will trigger the protection mechanism of the battery and the battery will no...

Page 19: ...rized service provider Do not place the device or the battery in or near heating equipment such as microwave ovens stoves or radiators Keep the device and the battery away from excessive heat and direct sunlight If not the device or the battery may overheat and cause explosion or fire Do not disassemble squeeze or puncture the device as this can cause explosion or fire Do not throw the device into...

Page 20: ... party products or usage in conjunction with third party products if such defects are due to the combined usage vii Any other cause beyond the range of normal usage intended for the product End users have no right to reject or return the product or receive a refund for the product from ZTE under the above mentioned situations This warranty is end users sole remedy and ZTE s sole liability for defe...

Page 21: ...ction with using of this product no matter whether or not ZTE had been advised knew or should have known of the possibility of such damages including but not limited to lost profits interruption of business cost of capital cost of substitute facilities or product or any downtime cost ...

Page 22: ...ranslated or utilized in any form or by any means electronic or mechanical including photocopying and microfilm without the prior written permission of ZTE Corporation The manual is published by ZTE Corporation We reserve the right to make modifications on print errors or update specifications without prior notice Version No R1 0 ...

Page 23: ...gh Wi Fi cannot be established Ensure that the Wi Fi function is enabled Refresh the network list and select the correct SSID Check the IP address and ensure that your client can automatically obtain an IP address Enter the correct network key Wi Fi password when you connect the client to your device ...

Page 24: ...ocation and find a place with good signal Check the settings of the WAN connection mode Contact your service provider and confirm your APN settings The 4G Mobile Hotspot configuration page cannot be visited Enter the correct address The default address is http 192 168 0 1 or http ufi ztedevice com Use only one network adapter in your PC Do not use any proxy server ...

Page 25: ...25 Getting More Help You can get help by Sending an email to mobile zte com cn Visiting www ztedevices com ...

Page 26: ...nd can radiated radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the u...

Page 27: ...ions that simulate RF exposure in usage against the head with no separation and near the body with the separation of 10 mm Although the SAR is determined at the highest certified power level the actual SAR level of the while operating can be well below the maximum value This is because the device is designed to operate at multiple power levels so as to use only the power required to reach the netw...

Page 28: ... on FCC ID SRQ MF971R For this device the highest reported SAR value for near the body is 1 09 W kg While there may be differences between the SAR levels of various devices and at various positions they all meet the government requirement SAR compliance for body operation is based on a separation distance of 10 mm between the unit and the human body Carry this device at least 10 mm away from your ...

Reviews: