background image

Zurn Industries, LLC

511 W. Freshwater Way, Milwaukee, WI U.S.A. 53204 · Ph. 1-855-ONE-ZURN, Fax 919-775-3541

In Canada

 

|

 

Zurn Industries Limited

7900 Goreway Drive Unit 10, Brampton, Ontario L6T5W6 · Ph. 905-405-8272, Fax 905-405-1292

www.zurn.com

Rev. A
Date: 3/26/2019
C.N. No. 

SAN008462

Prod. | Dwg. No.  

FV637

®

Cumberland Series™ 
Faucet

Sensor-Operated Lavatory Faucets for 
Battery or Plug-In Installations.

Installation, Operation, Maintenance, 
and Parts Manual

Patented and Patents Pending

Z6956-XL

Cumberland Series

Sensor-Operated Battery-Power or Plug-in 
Lavatory Faucets

NOTICE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT.

NOTE: The information in this manual is subject to change at any time without notice. Installations may 
be performed at different times of construction by different individuals. For this reason, these instructions 
should be left on-site with the facility or maintenance manager.

LIMITED WARRANTY

All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the 

date of purchase. Decorative fi nishes warranted for one year. We will replace at no costs goods that prove defective provided we are 

notifi ed in writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly 

maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages 

whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the 

defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the 

purchaser assumes all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantabil-

ity is expressly excluded. If the products sold hereunder are “consumer products,” the implied warranty of merchantability is limited to a 

period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists are 

approximate and are not guaranteed.

WARNING

: Cancer and Reproduc  ve Harm - www.P65Warnings.ca.gov

ADVERTENCIA: 

Cáncer y daño reproduc  vo - www.P65Warnings.ca.gov

AVERTISSEMENT: 

Cancer et e

 ets néfastes sur la reproduc  on - www.P65Warnings.ca.gov

Summary of Contents for Cumberland Series

Page 1: ...warranted for one year We will replace at no costs goods that prove defective provided we are notified in writing of such defect and the goods are returned to us prepaid at Sanford NC with evidence that they have been properly maintained and used in accordance with instructions We shall not be responsible for any labor charges or any loss injury or damages whatsoever including incidental or conseq...

Page 2: ...dequate water supply for each fixture Flush all water lines prior to making connections Required Tools Cumberland Series Faucet Package Contents Z6956 XL Prior to Installation Before installing your Zurn Cumberland Series Faucet the items listed below should already be installed on site Lavatory sink Drain Line Hot and cold water supply line or pre tempered water supply line Installer Servicer sho...

Page 3: ... washer and mounting nut and cover plate for versions that are included 1 3 Ensure that slot in plastic washer is facing forward 2 1 Assemble the electronics module NOTE Before installation turn off water supplies to existing faucet and remove faucet if replacing an existing device Clean the faucet basin and clear away debris Flush all supply lines before connecting the faucet Failure to do so may...

Page 4: ...K wire should be connected to the Negative terminal MJ unit sold separately Note Do not connect more than 8 solenoids to a single transformer 2 3 Tighten electronics module assembly to shank and connect water line s 2 4 Ensure that sink is clear of tools debris and is in normal operating condition 2 5 Turn on water supply ies Water supply must be turned on in order for sensor to perform wet calibr...

Page 5: ...t ac vate a er ini al installa on Sensor may not have had enough me to calibrate prior to a user or target trying to ini ate ac va on Disconnect the sensor and electronic box cables and wait for 30 seconds Reconnect the cables but allow for another 30 seconds before placing hands or a target within the sensor range You should hear a click of the solenoid once calibra on is complete Check if protec...

Page 6: ...6 XL B L 4 4 Cast Cover Plate w Gasket P6900 CP4 5 8 Cast Cover Plate w Gasket P6900 CP8 6 Mounting Kit P6900 43 7 Filter Kit P6900 120 8 Filter Screen P6900 MV 7 9 Mixing Valve w Filter P6900 XL MV 10 Mixing Tee w Filters and Back Checks P6900 XL MT Description Product No 11 Thermostatic Mixing Valve P6900 TMV 12 Single Stainless Supply Hose XL P6900 SSH 13 Stainless Supply Hoses XL P6900 SSH 2 1...

Reviews: